On-line speciation of chromium using a modified chelating resin and determination in industrial water samples by flame atomic absorption spectrometry

被引:27
|
作者
Tiwari, Shelja [1 ]
Sharma, Niharika [1 ]
Saxena, Reena [1 ]
机构
[1] Univ Delhi, Dept Chem, Kirori Mal Coll, Delhi 110007, India
关键词
SOLID-PHASE EXTRACTION; MULTIWALL CARBON NANOTUBES; ENVIRONMENTAL-SAMPLES; SELECTIVE SEPARATION; SILICA-GEL; METAL-IONS; PRECONCENTRATION SYSTEM; AQUEOUS SAMPLES; TRACE-ELEMENTS; NATURAL-WATERS;
D O I
10.1039/c5nj02283e
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A flow injection-flame atomic absorption spectrometry (FI-FAAS) system for the speciation of Cr(III)/Cr(VI) based on solid phase extraction (SPE) has been proposed. A newly synthesized resin, Amberlite XAD-16 modified with alpha-benzoin oxime was used as a solid phase extractor for the speciation of chromium. The sorbed Cr(III) on the resin was desorbed with 0.2 mol L-1 HNO3. The influence of various chemical and flow parameters on Cr(III) sorption was investigated. The selectivity of the proposed method towards Cr(III) sorption in the presence of interfering ions was also studied. The preconcentration factor and the limit of detection for the preconcentration time of 300 s were 76 and 0.14 ng mL(-1), respectively. The relative standard deviation was 1.0% (n = 6). The determination of total chromium was done after reducing Cr(VI) to Cr(III) using hydroxylamine hydrochloride. The concentration of Cr(VI) was then calculated by subtracting the Cr(III) concentration from the total chromium concentration. The proposed system was applied to industrial water samples and recoveries of spiked samples were >95%. The accuracy of the proposed method was studied by analyzing the standard reference material (SRM 1643e, Trace Elements in Water) supplied by NIST, USA.
引用
收藏
页码:1412 / 1419
页数:8
相关论文
共 50 条
  • [41] Determination of Trace Copper in Environmental Samples by Flame Atomic Absorption Spectrometry After On-line Selective Preconcentration with Thioacetamide Modified Silica Gel Mini-Column
    Xie Fa-Zhi
    Zhang Feng-Jun
    Xuan Han
    Ge Ye-Jun
    Wang Ying
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (11) : 1720 - 1724
  • [42] Synthesis/characterization of a new chelating resin and on-line solid phase extraction for the determination of Ag(I) and Pd(II) from water, cream, anode slime and converter samples by flow injection flame atomic absorption spectrometry
    Cetin, Tulin
    Tokalioglu, Serife
    Ulgen, Ahmet
    Sahan, Serkan
    Ozenturk, Ismail
    Soykan, Cengiz
    TALANTA, 2013, 105 : 340 - 346
  • [43] On-line preconcentration using a resin functionalized with 3,4-dihydroxybenzoic acid for the determination of trace elements in biological samples by thermospray flame furnace atomic absorption spectrometry
    Lemos, Valfredo A.
    Bezerra, Marcos A.
    Amorim, Fabio A. C.
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 157 (2-3) : 613 - 619
  • [44] Study of cross-linked poly(methacrylic acid) and polyvinylimidazole as selective adsorbents for on-line preconcentration and redox speciation of chromium with flame atomic absorption spectrometry determination
    Corazza, Marcela Zanetti
    Ribeiro, Emerson Schwingel
    Segatelli, Mariana Gava
    Teixeira Tarley, Cesar Ricardo
    MICROCHEMICAL JOURNAL, 2014, 117 : 18 - 26
  • [45] Determination of Molybdenum in Soil, Coal and Industrial Residue Samples by Flame Atomic Absorption Spectrometry
    Yigmatepe, Ergul
    Avci, Halim
    Yaman, Mehmet
    ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (03) : 1829 - 1834
  • [46] Speciation determination of chromium(III) and (VI) using preconcentration cloud point extraction with flame atomic absorption spectrometry (FAAS)
    Kiran, K.
    Kumar, K. Suresh
    Prasad, B.
    Suvardhan, K.
    Babu, Lekkala Ramesh
    Janardhanam, K.
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 150 (03) : 582 - 586
  • [47] Modified Peanut Shell Micro-Column Solid Phase Extraction for the Determination of Silver in Environmental Water Samples by Flame Atomic Absorption Spectrometry
    Yang, J.
    Zhang, Y. M.
    Chen, F. P.
    Zhang, H. X.
    ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (03) : 1289 - 1292
  • [48] Speciation of Chromium after Coprecipitation with Cu-Violuric Acid and Determination by Flame Atomic Absorption Spectrometry
    Saracoglu, S.
    Yilmaz, E.
    Soylak, M.
    CURRENT ANALYTICAL CHEMISTRY, 2012, 8 (03) : 358 - 364
  • [49] On-line preconcentration and determination of nickel and zinc in natural water samples by flow injection - flame atomic absorption spectrometry using PTFE-turnings for column packing
    Anthemidis, Aristidis N.
    Zachariadis, George A.
    Stratis, John A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2010, 90 (02) : 127 - 136
  • [50] An on-line separation and preconcentration system coupled with flame atomic absorption spectrometry for the determination of lead
    Dasbasi, Teslima
    Sacmaci, Serife
    Sahan, Serkan
    Ulgen, Ahmet
    Kartal, Senol
    ANALYTICAL METHODS, 2013, 5 (13) : 3307 - 3313