Clinical chemistry without reagents?: An infrared spectroscopic technique for determination of clinically relevant constituents of body fluids

被引:70
作者
Hosafci, Gamze
Klein, Oliver
Oremek, Gerhard
Maentele, Werner
机构
[1] Goethe Univ Frankfurt, Inst Biophys, D-60438 Frankfurt, Germany
[2] Univ Hosp Frankfurt, Res Dept Lab Med, Ctr Internal Med, D-60590 Frankfurt, Germany
关键词
blood analysis; urine analysis; body fluids; attenuated total reflection (ATR); infrared spectroscopy;
D O I
10.1007/s00216-006-0841-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A spectroscopic method based on attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy has been developed for reagent-free analysis of blood and urine constituents in the clinical laboratory and for point-of-care-applications. Blood plasma, whole blood, and urine were analyzed without any sample preparation, such as drying, concentration, or enrichment. Sample volumes as small as 5 mu L (a single drop of blood) can be used. Mathematical models, including partial least-squares regression, were used to construct a prediction model which can calculate the concentration of albumin, cholesterol, glucose, total protein, urea, and triglycerides in whole blood or blood plasma samples and the concentration of urea, uric acid, phosphate and creatinine in urine samples. The absolute precision and reproducibility of the prediction reached is sufficient for routine clinical analysis and is only limited by the precision of the reference analysis used for calibration. This was achieved by use of a large number of calibration samples (approx. 400 for blood samples and approx. 100 for urine samples) carefully selected for physiological and pathological range and for specific disease profiles.
引用
收藏
页码:1815 / 1822
页数:8
相关论文
共 12 条
[1]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING PARTIAL LEAST-SQUARES AND ARTIFICIAL NEURAL NETWORKS BASED ON MIDINFRARED SPECTROSCOPY [J].
BHANDARE, P ;
MENDELSON, Y ;
PEURA, RA ;
JANATSCH, G ;
KRUSEJARRES, JD ;
MARBACH, R ;
HEISE, HM .
APPLIED SPECTROSCOPY, 1993, 47 (08) :1214-1221
[2]   Application of molecular spectroscopy in the mid-infrared region to the determination of glucose and cholesterol in whole blood and in blood serum [J].
Budinova, G ;
Salva, J ;
Volka, K .
APPLIED SPECTROSCOPY, 1997, 51 (05) :631-635
[3]   Nanoliter serum sample analysis by mid-infrared spectroscopy for minimally invasive blood-glucose monitoring [J].
Diessel, E ;
Kamphaus, P ;
Grothe, K ;
Kurte, R ;
Damm, U ;
Heise, HM .
APPLIED SPECTROSCOPY, 2005, 59 (04) :442-451
[4]   Multivariate calibration for the determination of analytes in urine using mid-infrared attenuated total reflection spectroscopy [J].
Heise, HM ;
Voigt, G ;
Lampen, P ;
Küpper, L ;
Rudloff, S ;
Werner, G .
APPLIED SPECTROSCOPY, 2001, 55 (04) :434-443
[5]   MULTIVARIATE CALIBRATION FOR ASSAYS IN CLINICAL-CHEMISTRY USING ATTENUATED TOTAL REFLECTION INFRARED-SPECTRA OF HUMAN-BLOOD PLASMA [J].
JANATSCH, G ;
KRUSEJARRES, JD ;
MARBACH, R ;
HEISE, HM .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2016-2023
[6]  
Liu KZ, 2002, CLIN CHEM, V48, P499
[7]   FT-IR spectrometry analysis of plasma fatty acyl moieties selective mobilization during endurance exercise [J].
Petibois, C ;
Déléris, G .
BIOPOLYMERS, 2005, 77 (06) :345-353
[8]   Preliminary investigation of near-infrared spectroscopic measurements of urea, creatinine, glucose, protein, and ketone in urine [J].
Pezzaniti, JL ;
Jeng, TW ;
McDowell, L ;
Oosta, GM .
CLINICAL BIOCHEMISTRY, 2001, 34 (03) :239-246
[9]   Comparison of mid-infrared and Raman spectroscopy in the quantitative analysis of serum -: art. no. 031108 [J].
Rohleder, D ;
Kocherscheidt, G ;
Gerber, K ;
Kiefer, W ;
Köhler, W ;
Möcks, J ;
Petrich, W .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (03)
[10]  
Shaw RA, 2000, CLIN CHEM, V46, P1493