Medial femoral plate with cannulated screw for Pauwels type III femoral neck fracture: A meta-analysis

被引:15
|
作者
Su, Zhengbing [1 ]
Liang, Linlin [2 ]
Hao, Yong [1 ]
机构
[1] Army Med Univ, Dept Orthoped, Affiliated Hosp 2, 83 Xinqiao Main St, Chongqing 400037, Peoples R China
[2] Second Peoples Hosp Jiulongpo Dist Chongqing, Dept Clin Lab, Chongqing, Peoples R China
关键词
Internal fixation; Pauwels type III; femoral neck fracture; meta-analysis; FIXATION; MANAGEMENT; SURGERY; ADULTS; RISK;
D O I
10.3233/BMR-200183
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Femoral neck fractures often occur in the elderly, which usually results in hip pain. OBJECTIVE: The purpose of this study was to evaluate the difference in the treatment of Pauwels type III femoral neck fractures with medial femoral support plate combined with cannulated screws and cannulated screws alone. METHODS: PubMed, ScienceDirect, China Academic Journals Full-text Database (CNKI), Wanfang Database, Chinese Biomedical Literature Database (CBM), Embase and Cochrane Library were used to collect clinical controlled trials of the medial femoral support plate combined with hollow screw internal fixation and simple hollow screw internal fixation for Pauwels type III femoral neck fracture. RESULTS: Seven articles (n = 409 cases) were evaluated for quality and included in this meta-analysis. Four hundred and nine patients with Pauwels type III femoral neck fractures were included: 202 in the experimental group and 207 in the control group. The results showed that, compared with simple hollow screw internal fixation, the medial femoral support plate combined with hollow screw internal fixation has a longer operation time (MD = 23.05, 95% CI = 13.86-32.24), and more intraoperative blood loss (MD = 91.55, 95% CI = 50.72-132.39), shorter healing time (MD = -1.48, 95% CI ( 1.71, 1.26)), lower incidence of complications (RR = 0.34, 95% CI = 0.19-0.61), lower VAS score (MD = -1.28, 95% CI ( 1.83, 0.72)), and higher Harris score (MD = 8.49, 95% CI (4.15, 12.83)). CONCLUSION: Medial femoral plate combined with cannulated screw for Pauwels type III femoral neck fracture can shorten healing time, reduce postoperative complications, and improve the postoperative Harris score.
引用
收藏
页码:169 / 177
页数:9
相关论文
共 50 条
  • [1] Comparison of Cannulated Screw Combined with Medial Femoral Plate and Simple Cannulated Screw in the Treatment of Pauwels Type III Femoral Neck Fracture: A Meta-analysis with Trial Sequential Analysis
    Li, Ming
    Ren, Cheng
    Ma, Teng
    Li, Zhong
    Xu, Yibo
    Sun, Liang
    Lu, Yao
    Wang, Qian
    Xue, Hanzhong
    Huang, Qiang
    Zhang, Kun
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (07): : 792 - 798
  • [2] Dynamic Hip Screw versus Cannulated Cancellous Screw in Pauwels Type II or Type III Femoral Neck Fracture: A Systematic Review and Meta-Analysis
    Lim, Eic Ju
    Shon, Hyun-Chul
    Cho, Jae-Woo
    Oh, Jong-Keon
    Kim, Junhyun
    Kim, Chul-Ho
    JOURNAL OF PERSONALIZED MEDICINE, 2021, 11 (10):
  • [3] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Gao, Zhichao
    Wang, Mei
    Shen, Baojie
    Chu, Xiaodong
    Ruan, Di
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [4] Treatment of Pauwels type III femoral neck fracture with medial femoral neck support screw: a biomechanical and clinical study
    Zhichao Gao
    Mei Wang
    Baojie Shen
    Xiaodong Chu
    Di Ruan
    Scientific Reports, 11
  • [5] Biomechanical comparison of femoral neck system and cannulated screws coupled with medial plate for treating Pauwels III femoral neck fractures
    Nan, Chong
    Li, Yanjun
    Liu, Yuxiu
    Ma, Liang
    Ma, Zhanbei
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (04) : 1161 - 1170
  • [6] The role of the medial plate for Pauwels type III femoral neck fracture: a comparative mechanical study using two fixations with cannulated screws
    Giordano, Vincenzo
    Alves, Danilo Diniz
    Paes, Roger Pletsch
    Amaral, Arthur Bonfim
    Giordano, Marcos
    Belangero, William
    Freitas, Anderson
    Koch, Hilton A.
    do Amaral, Ney Pecegueiro
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2019, 6 (01)
  • [7] The role of the medial plate for Pauwels type III femoral neck fracture: a comparative mechanical study using two fixations with cannulated screws
    Vincenzo Giordano
    Danilo Diniz Alves
    Roger Pletsch Paes
    Arthur Bonfim Amaral
    Marcos Giordano
    William Belangero
    Anderson Freitas
    Hilton A. Koch
    Ney Pecegueiro do Amaral
    Journal of Experimental Orthopaedics, 6
  • [8] Femoral Neck System vs. four cannulated screws in the treatment of Pauwels III femoral neck fracture
    Lin, Hongkuan
    Lai, Caosheng
    Zhou, Zhiping
    Wang, Chaoqiang
    Yu, Xinlin
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (06) : 1373 - 1378
  • [9] Modified cannulated screw fixation in the treatment of Pauwels type III femoral neck fractures: A biomechanical study
    Zhou, Lin
    Lin, Jiaming
    Huang, Anfei
    Gan, Weidong
    Zhai, Xu
    Sun, Kai
    Huang, Shiqing
    Li, Zhizhong
    CLINICAL BIOMECHANICS, 2020, 74 : 103 - 110
  • [10] Finite element analysis of femoral neck system in the treatment of Pauwels type III femoral neck fracture
    Teng, Yanbin
    Zhang, Yan
    Guo, Chaowei
    MEDICINE, 2022, 101 (28) : E29450