Rescuer fatigue during actual in-hospital cardiopulmonary resuscitation with audiovisual feedback: A prospective multicenter study

被引:156
作者
Sugerman, Noah T. [1 ]
Edelson, Dana P. [2 ]
Leary, Marion [1 ]
Weidman, Elizabeth K. [2 ]
Herzberg, Daniel L. [1 ]
Hoek, Terry L. Vanden [3 ]
Becker, Lance B. [1 ]
Abella, Benjamin S. [1 ,4 ]
机构
[1] Univ Penn, Ctr Resuscitat Sci, Dept Emergency Med, Sch Med, Philadelphia, PA 19104 USA
[2] Univ Chicago, Sect Hosp Med, Dept Med, Pritzker Sch Med, Chicago, IL 60637 USA
[3] Univ Chicago, Sect Emergency Med, Dept Med, Pritzker Sch Med, Chicago, IL 60637 USA
[4] Univ Penn, Div Pulm Allergy & Crit Care, Dept Med, Sch Med, Philadelphia, PA 19104 USA
关键词
Cardiopulmonary resuscitation; Cardiac arrest; Quality of care; CARDIAC-ARREST; CHEST COMPRESSIONS; QUALITY; CPR; TIME; IMPROVEMENT; SURVIVAL; DEPTH;
D O I
10.1016/j.resuscitation.2009.06.002
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Rescuer fatigue during cardiopulmonary resuscitation (CPR) is a likely contributor to variable CPR quality during clinical resuscitation efforts, yet investigations into fatigue and CPR quality degradation have only been performed in simulated environments, with widely conflicting results. Objective: We sought to characterize CPR quality decay during actual in-hospital cardiac arrest, with regard to both chest compression (CC) rate and depth during the delivery of CCs by individual rescuers over time. Methods: Using CPR recording technology to objectively quantify CCs and provide audiovisual feedback, we prospectively collected CPR performance data from arrest events in two hospitals. We identified continuous CPR "blocks" from individual rescuers, assessing CC rate and depth over time. Results: 135 blocks of continuous CPR were identified from 42 cardiac arrests at the two institutions. Median duration of continuous CPR blocks was 112 s (IQR 101-122). CC rate did not change significantly over single rescuer performance, with an initial mean rate of 105 +/- 11/min, and a mean rate after 3 min of 106 +/- 9/min (p = NS). However, CC depth decayed significantly between 90 s and 2 min, falling from a mean of 48.3 +/- 9.6 mm to 46.0 +/- 9.0 mm (p = 0.0006) and to 43.7 +/- 7.4 mm by 3 min (p = 0.002). Conclusions: During actual in-hospital CPR with audiovisual feedback, CC depth decay became evident after 90 s of CPR, but CC rate did not change. These data provide clinical evidence for rescuer fatigue during actual resuscitations and support current guideline recommendations to rotate rescuers during CC delivery. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:981 / 984
页数:4
相关论文
共 21 条
[1]   CPR quality improvement during in-hospital cardiac arrest using a real-time audiovisual feedback system [J].
Abella, Benjamin S. ;
Edelson, Dana P. ;
Kim, Salem ;
Retzer, Elizabeth ;
Myklebust, Helge ;
Barry, Anne M. ;
O'Hearn, Nicholas ;
Hoek, Terry L. Vanden ;
Becker, Lance B. .
RESUSCITATION, 2007, 73 (01) :54-61
[2]   Quality of cardiopulmonary resuscitation during in-hospital cardiac arrest [J].
Abella, BS ;
Alvarado, JP ;
Myklebust, H ;
Edelson, DP ;
Barry, A ;
O'Hearn, N ;
Vanden Hoek, TL ;
Becker, LB .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (03) :305-310
[3]   Chest compression rates during cardiopulmonary resuscitation are suboptimal - A prospective study during in-hospital cardiac arrest [J].
Abella, BS ;
Sandbo, N ;
Vassilatos, P ;
Alvarado, JP ;
O'Hearn, N ;
Wigder, HN ;
Hoffman, P ;
Tynus, K ;
Vanden Hoek, TL ;
Becker, LB .
CIRCULATION, 2005, 111 (04) :428-434
[4]   Effect of rescuer fatigue on performance of continuous external chest compressions over 3 min [J].
Ashton, A ;
McCluskey, A ;
Gwinnutt, CL ;
Keenan, AM .
RESUSCITATION, 2002, 55 (02) :151-155
[5]   Quality of chest compressions during 10 min of single-rescuer basic life support with different compression: ventilation ratios in a manikin model [J].
Biorshol, Conrad Arnfinn ;
Soreide, Eldar ;
Torsteinbo, Tor Harald ;
Lexow, Kristian ;
Nilsen, Odd Bjarte ;
Sunde, Kjetil .
RESUSCITATION, 2008, 77 (01) :95-100
[6]   Improvement in timing and effectiveness of external cardiac compressions with a new non-invasive device: the CPR-Ezy [J].
Boyle, AJ ;
Wilson, AM ;
Connelly, K ;
McGuigan, L ;
Wilson, J ;
Whitbourn, R .
RESUSCITATION, 2002, 54 (01) :63-67
[7]   Effects of compression depth and pre-shock pauses predict defibrillation failure during cardiac arrest [J].
Edelson, Dana P. ;
Abella, Benjamin S. ;
Kramer-Johansen, Jo ;
Wik, Lars ;
Myklebust, Helge ;
Barry, Anne M. ;
Merchant, Raina M. ;
Vanden Hoek, Terry L. ;
Steen, Petter A. ;
Becker, Lance B. .
RESUSCITATION, 2006, 71 (02) :137-145
[8]   EFFECTIVENESS OF BYSTANDER CARDIOPULMONARY-RESUSCITATION AND SURVIVAL FOLLOWING OUT-OF-HOSPITAL CARDIAC-ARREST [J].
GALLAGHER, EJ ;
LOMBARDI, G ;
GENNIS, P .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (24) :1922-1925
[9]   Rescuer fatigue: Standard versus continuous chest-compression cardiopulmonary resuscitation [J].
Heidenreich, Joseph W. ;
Berg, Robert A. ;
Higdon, Travis A. ;
Ewy, Gordon A. ;
Kern, Karl B. ;
Sanders, Arthur B. .
ACADEMIC EMERGENCY MEDICINE, 2006, 13 (10) :1020-1026
[10]   DECAY IN QUALITY OF CLOSED-CHEST COMPRESSIONS OVER TIME [J].
HIGHTOWER, D ;
THOMAS, SH ;
STONE, CK ;
DUNN, K ;
MARCH, JA .
ANNALS OF EMERGENCY MEDICINE, 1995, 26 (03) :300-303