Current applications of advanced cross-sectional imaging techniques in evaluating the painful arthroplasty

被引:13
作者
Sofka, Carolyn M. [1 ]
机构
[1] Cornell Univ, Hosp Special Surg, Weill Med Coll, New York, NY 10021 USA
关键词
arthroplasty; osteolysis; periprosthetic soft tissues; metallic artifact; interventional sonography;
D O I
10.1007/s00256-006-0226-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patients with a painful arthroplasty can present a clinical diagnostic dilemma. Aspirates are often negative for infection and alignment of the prosthesis on conventional radiographs is usually satisfactory. These patients can have a myriad of soft tissue as well as osseous pathologies, which may be clinically unsuspected or radiographically occult. The ability of advanced cross-sectional imaging to diagnose osseous and soft tissue injuries has been well documented, but applications to arthroplasty imaging are often limited by regional metallic artifacts. Adjustment of standard imaging parameters can make CT and MR imaging useful adjuncts in imaging the painful arthroplasty, especially in the setting of normal radiographs. Ultrasound can be used to evaluate the periprosthetic soft tissues and provide a real-time method of evaluating the dynamic relationship of the periprosthetic soft tissues to the arthroplasty components, and it also can be used as a guide for diagnostic and therapeutic interventions.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 50 条
[1]   Diagnostic and therapeutic use of sonography-guided iliopsoas peritendinous injections [J].
Adler, RS ;
Buly, R ;
Ambrose, R ;
Sculco, T .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (04) :940-943
[2]   Sonography of the iliopsoas tendon and injection of the iliopsoas Bursa for diagnosis and management of the painful snapping hip [J].
Blankenbaker, DG ;
De Smet, AA ;
Keene, JS .
SKELETAL RADIOLOGY, 2006, 35 (08) :565-571
[3]   Multichannel CT imaging of orthopedic hardware and implants [J].
Buckwalter, KA ;
Parr, JA ;
Choplin, RH ;
Capello, WN .
SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2006, 10 (01) :86-97
[4]   Computed tomography to assess pelvic lysis after total hip replacement [J].
Claus, AM ;
Totterman, SM ;
Sychterz, CJ ;
Tamez-Peña, JG ;
Looney, RJ ;
Engh, CA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (422) :167-174
[5]  
COOK JG, 1986, ADV SERIALS MANAGEME, V1, P53
[6]   Avoiding pitfalls and complications in total shoulder arthroplasty [J].
Cuomo, F ;
Checroun, A .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1998, 29 (03) :507-+
[7]   Metallic prosthesis: Technique to avoid increase in CT radiation dose with automatic tube current modulation in a phantom and patients [J].
Dalal, T ;
Kalra, MK ;
Rizzo, SMR ;
Schmidt, B ;
Suess, C ;
Flohr, T ;
Blake, MA ;
Saini, S .
RADIOLOGY, 2005, 236 (02) :671-675
[8]   Using sonography to reveal and aspirate joint effusions [J].
Fessell, DP ;
Jacobson, JA ;
Craig, J ;
Habra, G ;
Prasad, A ;
Radliff, A ;
van Holsbeeck, MT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) :1353-1362
[9]  
FIALA TGS, 1993, PLAST RECONSTR SURG, V92, P1227
[10]   METALLIC HIP IMPLANTS - CT WITH MULTIPLANAR RECONSTRUCTION [J].
FISHMAN, EK ;
MAGID, D ;
ROBERTSON, DD ;
BROOKER, AF ;
WEISS, P ;
SIEGELMAN, SS .
RADIOLOGY, 1986, 160 (03) :675-681