Do strain gauge force platforms need in situ correction?

被引:27
作者
Chockalingam, N
Giakas, G
Iossifidou, A
机构
[1] Staffordshire Univ, Sch Hlth, Stoke On Trent ST4 2DF, Staffs, England
[2] Univ Manchester, Hope Hosp, Dept Geriatr Med, SATRU, Salford M6 8HD, Lancs, England
关键词
biomechanics; ground reaction force; testing; gait analysis;
D O I
10.1016/S0966-6362(02)00017-6
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study presents a simple method for checking the accuracy of force platform systems. The accuracy is assigned by the offset of the calculated centre of pressure, relative to its geometric location on the surface of the platform. A dynamic force that changes over time was applied, as opposed to previous methods based on static forces. Measurements by two researchers on two strain gauge based platforms indicated a decrease in accuracy as the point of application of force moves to the platform peripheries. It was also found that the minimum vertical force threshold might be up to 113 N in order to estimate the centre of pressure within a distance with a S.D. of 0.3 cm. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:233 / 237
页数:5
相关论文
共 11 条
[1]   ACCURACY OF DETERMINING THE POINT OF FORCE APPLICATION WITH PIEZOELECTRIC FORCE PLATES [J].
BOBBERT, MF ;
SCHAMHARDT, HC .
JOURNAL OF BIOMECHANICS, 1990, 23 (07) :705-710
[2]  
DAVIS BL, 1997, P 16 C INT SOC BIOM, P136
[3]   A new testing rig for force platform calibration and accuracy tests [J].
Gill, HS ;
OConnor, JJ .
GAIT & POSTURE, 1997, 5 (03) :228-232
[4]   Static in situ calibration of force plates [J].
Hall, MG ;
Fleming, HE ;
Dolan, MJ ;
Millbank, SFD ;
Paul, JP .
JOURNAL OF BIOMECHANICS, 1996, 29 (05) :659-665
[5]   AN INVERSE DYNAMICS MODEL FOR THE ANALYSIS, RECONSTRUCTION AND PREDICTION OF BIPEDAL WALKING [J].
KOOPMAN, B ;
GROOTENBOER, HJ ;
DEJONGH, HJ .
JOURNAL OF BIOMECHANICS, 1995, 28 (11) :1369-1376
[6]   CONTROL OF WHOLE-BODY BALANCE IN THE FRONTAL PLANE DURING HUMAN WALKING [J].
MACKINNON, CD ;
WINTER, DA .
JOURNAL OF BIOMECHANICS, 1993, 26 (06) :633-644
[7]   ERRORS IN ALIGNMENT OF CENTER OF PRESSURE AND FOOT COORDINATES AFFECT PREDICTED LOWER-EXTREMITY TORQUES [J].
MCCAW, ST ;
DEVITA, P .
JOURNAL OF BIOMECHANICS, 1995, 28 (08) :985-988
[8]   Accuracy of centre of pressure measurement using a piezoelectric force platform [J].
Middleton, J ;
Sinclair, P ;
Patton, R .
CLINICAL BIOMECHANICS, 1999, 14 (05) :357-360
[9]   Parameters influencing the accuracy of the point of force application determined with piezoelectric force plates [J].
Schmiedmayer, HB ;
Kastner, J .
JOURNAL OF BIOMECHANICS, 1999, 32 (11) :1237-1242
[10]  
SOMMER R, 1997, P 16 ISB C TOK, P18