Response and Protection of DFIG System under Grid Fault

被引:0
|
作者
Zhang, Xing [1 ]
Li, Qin [1 ]
Yang, Shuying [1 ]
Xie, Zhen [1 ]
Cao Renxian [2 ]
机构
[1] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei, Peoples R China
[2] Hefei Sungrow Power Supply Co Ltd, Hefei, Peoples R China
关键词
DFIG; voltage drop; voltage recovery; stator flux; rotor voltage; FED INDUCTION GENERATOR;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The use of doubly fed induction generators (DFIG) in large wind turbines has become quite common over the last few years. However, DFIG are very sensitive to grid disturbances, especially to voltage dips, therefore low voltage ride-through(LVRT) technology for DFIG becomes one of the critical technology in the uninterrupted operation of wind power generation. In order to help the study of low voltage ride-through(LVRT) technology for DFIG, a detailed thoretical analysis of the dynamic behavior of DFIG during grid voltage drop and recovery has been proposed, and obtained the maximum instantaneous rotor voltage when the voltage drop and the maximum and minimum rotor voltage when voltage recovery, then given the relevant simulation waveform. At last, the method on crowbar design is proposed.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Protection System Behavior of DFIG Based Wind Farms for Grid-Faults with Practical Considerations
    Kawady, Tamer
    Feltes, Christian
    Erlich, Istvan
    Taalab, A. I.
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [32] Active Control Method for Torsional Vibration of DFIG Drive Chain Under Asymmetric Power Grid Fault
    Tian, Shiji
    Li, Zhongyi
    Li, Hui
    Hu, Yihua
    Lu, Min
    IEEE ACCESS, 2020, 8 (08): : 155611 - 155618
  • [33] Short Circuit Current Analysis of DFIG-type WG with Crowbar Protection under Grid Faults
    Zheng, Zhong
    Yang, Geng
    Geng, Hua
    2012 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2012, : 1072 - 1079
  • [34] Transient Characteristics of VSC-HVDC System and its Effects on Distance Protection under AC Grid Fault
    Xiao, Chao
    Ouyang, Jinxin
    Xiong, Xiaofu
    Ma, Getu
    Zheng, Di
    JOURNAL OF APPLIED SCIENCE AND ENGINEERING, 2018, 21 (04): : 577 - 586
  • [35] Superconducting Fault Current Limiter for Grid Connected Power System Protection
    Naresh, Maloth
    Singh, Navneet Kumar
    Singh, Asheesh Kumar
    PROCEEDINGS 2016 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2016, : 576 - 581
  • [36] Coordinated Control Strategy for Grid Connected DFIG wind System under Voltage Imbalance
    Ramalingeswar, J. T.
    Subramanian, K.
    2017 IEEE INTERNATIONAL CONFERENCE ON POWER, CONTROL, SIGNALS AND INSTRUMENTATION ENGINEERING (ICPCSI), 2017, : 1946 - 1951
  • [37] Influence of DFIG Models on Fault Current Calculation and Protection Coordination
    Zhao, S.
    Qureshi, W. A.
    Nair, N. -K. C.
    2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2011,
  • [38] Fault characteristic and protection performance under grid-forming control objective
    Xie, Hua
    Huang, Tao
    Xu, Xiaochun
    Zhao, Qingchun
    Wang, Nannan
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2024, 44 (11): : 210 - 216
  • [39] Study of a Three Level Converter Interfaced Vector Controlled DFIG System under Fault
    Shukla, Sandeep
    Dwivedi, U. D.
    Tripathi, R. K.
    2013 STUDENTS CONFERENCE ON ENGINEERING AND SYSTEMS (SCES): INSPIRING ENGINEERING AND SYSTEMS FOR SUSTAINABLE DEVELOPMENT, 2013,
  • [40] A Control Strategy of DFIG under Unbalanced Grid Voltage
    Xiao, Hui
    Liu, Feiyan
    ELEKTRONIKA IR ELEKTROTECHNIKA, 2013, 19 (09) : 15 - 20