Response and Protection of DFIG System under Grid Fault

被引:0
|
作者
Zhang, Xing [1 ]
Li, Qin [1 ]
Yang, Shuying [1 ]
Xie, Zhen [1 ]
Cao Renxian [2 ]
机构
[1] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei, Peoples R China
[2] Hefei Sungrow Power Supply Co Ltd, Hefei, Peoples R China
关键词
DFIG; voltage drop; voltage recovery; stator flux; rotor voltage; FED INDUCTION GENERATOR;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The use of doubly fed induction generators (DFIG) in large wind turbines has become quite common over the last few years. However, DFIG are very sensitive to grid disturbances, especially to voltage dips, therefore low voltage ride-through(LVRT) technology for DFIG becomes one of the critical technology in the uninterrupted operation of wind power generation. In order to help the study of low voltage ride-through(LVRT) technology for DFIG, a detailed thoretical analysis of the dynamic behavior of DFIG during grid voltage drop and recovery has been proposed, and obtained the maximum instantaneous rotor voltage when the voltage drop and the maximum and minimum rotor voltage when voltage recovery, then given the relevant simulation waveform. At last, the method on crowbar design is proposed.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Response and protection of DFIG system under three-phase short circuit fault of grid
    Guo, Jia-Hu
    Zhang, Lu-Hua
    Cai, Xu
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (06): : 40 - 44
  • [2] Dynamic Response of Wind Power Generation Based on DFIG under Grid Fault
    Guo Jia-Hu
    Zhang Lu-hua
    Cai Xu
    2009 IEEE 6TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-4, 2009, : 1443 - 1446
  • [3] Dynamic response of wind power generation based on DFIG under grid fault
    Guo, Jiahu
    Zhang, Luhua
    Cai, Xu
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2010, 31 (08): : 1023 - 1029
  • [4] Evaluation and analysis of transient current of a DFIG wind generation system under grid fault
    Li, Hui
    Zhao, Meng
    Ye, Ren-Jie
    Tang, Xian-Hu
    Liu, Zhi-Xiang
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2010, 14 (08): : 45 - 51
  • [5] Protection strategy of DFIG under grid voltage narrow dip
    Cai, Zhi
    Liu, Jian-Zheng
    Mei, Hong-Ming
    Wang, Jian
    Liu, Shu
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2009, 37 (21): : 41 - 44
  • [6] Control Strategies for DFIG Wind Turbines Under Grid Fault Conditions
    Luna, A.
    Rolan, A.
    Medeiros, G.
    Rodriguez, P.
    Teodorescu, R.
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 3691 - +
  • [7] Partial Non -Zero Fault Response of Grid-Connected DFIG
    Pannell, G.
    Gadoue, S.
    Zahawi, B.
    Atkinson, D. J.
    2018 XIII INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2018, : 1630 - 1635
  • [8] FAULT RESPONSE FOR GRID CONNECTED OWPP WITH DFIG. ANALYTICAL APPROACH
    Sava, Gabriela
    Costinas, Sorina
    Golovanov, Nicolae
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2014, 76 (04): : 161 - 168
  • [9] Analytical Study Of grid connected DFIG Based Wind turbine Under Grid Fault Conditions
    Moussaoui, M.
    Mezouar, A.
    Boumediene, L.
    Benyahia, Kh.
    Laagueb, M.
    2015 7TH INTERNATIONAL CONFERENCE ON MODELLING, IDENTIFICATION AND CONTROL (ICMIC), 2014, : 875 - 880
  • [10] Assessment of DFIG wind turbine overvoltage protection system for grid stability
    Beniuga, Razvan
    Beniuga, Oana
    Machidon, Dragon
    PROCEEDINGS OF 2019 8TH INTERNATIONAL CONFERENCE ON MODERN POWER SYSTEMS (MPS), 2019,