Continued provision of WHO International Standards for total and free PSA: Content and commutability of replacement preparations

被引:7
作者
Ferguson, Jackie [1 ]
Patel, Dina [2 ]
Atkinson, Eleanor [3 ]
Rigsby, Peter [3 ]
Burns, Chris [1 ]
机构
[1] Natl Inst Biol Stand & Controls, Biotherapeut Grp, Blanche Lane, Potters Bar EN6 3QG, Herts, England
[2] Northern Gen Hosp, UK NEQAS Immunol Immunochem & Allergy, POB 894, Sheffield S5 7YT, S Yorkshire, England
[3] Natl Inst Biol Stand & Controls, Biostat Grp, Blanche Lane, Potters Bar EN6 3QG, Herts, England
关键词
WHO International Standard; PSA; Prostate cancer; Immunoassay; Commutability; PROSTATE-SPECIFIC ANTIGEN; TRANSITION ZONE; MOLECULAR-FORM; ASSAY-METHODS; CANCER; VARIABILITY; INTERCHANGEABILITY; CALIBRATION; SERUM; FLUID;
D O I
10.1016/j.clinbiochem.2019.07.007
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives: Replacements are required for the WHO International Standards (IS) for free PSA, coded 96/668 and total PSA (90:10), coded 96/670, which were established in 1999 to support efforts to harmonise PSA assays and address non-equimolarity. An important consideration is that the introduction of the replacements should have minimal impact on PSA measurements. Design and methods: We report the development of a replacement strategy, informed by field assessment of preparations through an external quality assessment scheme and the subsequent evaluation of the candidate ISs in worldwide collaborative studies. Results: By immunoassay, data from participants confirmed the value assigned to the current standards. Robust geometric mean estimates of the free PSA content of the candidate replacement for 96/668 coded 17/102 was 0.533 mu g/ampoule (n = 21). The ratio of the content estimates of 17/102:96/668 was 0.516 (GCV 12.5%, n = 21). Robust geometric mean estimates of the total PSA content of the candidate replacement for 96/670, coded 17/100, was 0.505 mu g/ampoule (n = 22). The ratio of the content estimates of 17/100:96/670 was 0.490 (GCV 5.3%, n = 22). Through concomitant measurement of a panel of 15 representative patient samples, the candidate ISs were shown to exhibit commutability with patient samples that was comparable with that of the current ISs. Conclusion: On the basis of these results, the preparations coded 17/102 and 17/100 were established by the WHO Expert Committee on Biological Standardization as the 2nd ISs for free and total PSA (PSA-ACT+free PSA) respectively, with assigned contents of 0.53 mu g/ampoule and 0.50 mu g/ampoule.
引用
收藏
页码:58 / 66
页数:9
相关论文
共 35 条
[1]  
[Anonymous], WHOBS20182340 ECBS
[2]  
[Anonymous], WHOBS20182339 ECBS
[3]  
[Anonymous], 2004, WHO TECH REP SER
[4]  
[Anonymous], 2010, BMJ BRIT MED J, DOI DOI 10.1136/BMJ.C4543
[5]   Discordant prostate specific antigen test results despite WHO assay standardization [J].
Boegemann, Martin ;
Arsov, Christian ;
Hadaschik, Boris ;
Herkommer, Kathleen ;
Imkamp, Florian ;
Nofer, Jerzy-Roch ;
Gerss, Joachim ;
Albers, Peter ;
Semjonow, Axel .
INTERNATIONAL JOURNAL OF BIOLOGICAL MARKERS, 2018, 33 (03) :275-282
[6]  
CHEN ZX, 1995, CLIN CHEM, V41, P1273
[7]   ENZYMATIC-ACTIVITY OF PROSTATE-SPECIFIC ANTIGEN AND ITS REACTIONS WITH EXTRACELLULAR SERINE PROTEINASE-INHIBITORS [J].
CHRISTENSSON, A ;
LAURELL, CB ;
LILJA, H .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1990, 194 (03) :755-763
[8]   Variability of assay methods for total and free PSA after WHO standardization [J].
Foj, L. ;
Filella, X. ;
Alcover, J. ;
Auge, J. M. ;
Escudero, J. M. ;
Molina, R. .
TUMOR BIOLOGY, 2014, 35 (03) :1867-1873
[9]   Standardization of assay methods reduces variability of total PSA measurements: an Irish study [J].
Forde, James C. ;
Marignol, Laure ;
Blake, Ophelia ;
McDermott, Ted ;
Grainger, Ronald ;
Crowley, Vivien E. ;
Lynch, Thomas H. .
BJU INTERNATIONAL, 2012, 110 (05) :644-650
[10]   PROCEDURES FOR DETECTING OUTLYING OBSERVATIONS IN SAMPLES [J].
GRUBBS, FE .
TECHNOMETRICS, 1969, 11 (01) :1-&