Characterization of silicone elastomer vaginal rings containing HIV microbicide TMC120 by Raman spectroscopy

被引:21
作者
Bell, Steven E. J.
Dennis, Andrew C.
Fido, Louise A.
Malcolm, R. Karl
Sirimuthu, Narayana M. S.
Toner, Clare F.
Woolfson, A. David
机构
[1] Queens Univ Belfast, Innovat Mol Mat Grp, Sch Chem & Chem Engn, Belfast BT9 5AG, Antrim, North Ireland
[2] Avalon Instruments Ltd, Belfast BT9 5DJ, Antrim, North Ireland
[3] Queens Univ Belfast, Sch Pharm, Belfast BT9 7BL, Antrim, North Ireland
关键词
D O I
10.1211/jpp.59.2.0007
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Silicone elastomer vaginal rings are currently being pursued as a control led-release strategy for delivering microbicidal substances for the prevention of heterosexual transmission of HIV. Although it is well established that the distribution of drugs in delivery systems influences the release characteristics, in practice the distribution is often difficult to quantify in-situ. Therefore, the aim of this work was to determine whether Raman spectroscopy might provide a rapid, non-contact means of measuring the concentrations of the lead candidate HIV microbicide TMC120 in a silicone elastomer reservoir-type vaginal ring. Vaginal rings loaded with TMC120 were manufactured and sectioned before either Raman mapping an entire ring cross-section (100 pm resolution) or running line scans at appropriate time intervals up to 30 h after manufacture. The results demonstrated that detectable amounts of TMC120, above the silicone elastomer saturation concentration, could be detected up to 1 mm into the sheath, presumably as a consequence of permeation and subsequent reprecipitation. The extent of permeation was found to be similar in rings manufactured at 25 and 80 degrees C.
引用
收藏
页码:203 / 207
页数:5
相关论文
共 6 条
  • [1] Development of sampling methods for Raman analysis of solid dosage forms of therapeutic and illicit drugs
    Bell, SEJ
    Beattie, JR
    McGarvey, JJ
    Peters, KL
    Sirimuthu, NMS
    Speers, SJ
    [J]. JOURNAL OF RAMAN SPECTROSCOPY, 2004, 35 (05) : 409 - 417
  • [2] Rapid analysis of ecstasy and related phenethylamines in seized tablets by Raman spectroscopy
    Bell, SEJ
    Burns, DT
    Dennis, AC
    Speers, JS
    [J]. ANALYST, 2000, 125 (03) : 541 - 544
  • [3] Chemical image fusion. The synergy of FT-NIR and Raman mapping microscopy to enable a move complete visualization of pharmaceutical formulations
    Clarke, FC
    Jamieson, MJ
    Clark, DA
    Hammond, SV
    Jee, RD
    Moffat, AC
    [J]. ANALYTICAL CHEMISTRY, 2001, 73 (10) : 2213 - 2220
  • [4] Long-term, controlled release of the HIV microbicide TMC120 from silicone elastomer vaginal rings
    Malcolm, RK
    Woolfson, AD
    Toner, CF
    Morrow, RJ
    McCullagh, SD
    [J]. JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2005, 56 (05) : 954 - 956
  • [5] MALCOLM RK, 2004, BIOTECHNOL GENET ENG, V21, P81
  • [6] WILLIAMS AC, 2001, HDB RAMAN SPECTROSCO, P575