Evaluation of a Polyethylene Glycol Phantom for Measuring Apparent Diffusion Coefficients Using Three 3.0 T MRI Systems

被引:2
作者
Sato, Eisuke [1 ]
Fukuzawa, Kei [2 ]
Takashima, Hiroyuki [3 ]
Yamatani, Yuya [4 ]
Takatsu, Yasuo [5 ]
Hata, Junichi [6 ]
Hikishima, Keigo [7 ]
Miwa, Kenta [8 ]
机构
[1] Juntendo Univ, Fac Hlth Sci, Dept Radiol Technol, Bunkyo Ku, 3-2-12 Hongo, Tokyo 1130033, Japan
[2] Toranomon Gen Hosp, Dept Radiol Technol, Tokyo, Japan
[3] Sapporo Med Univ Hosp, Div Radiol & Nucl Med, Sapporo, Hokkaido, Japan
[4] Nara Med Univ Hosp, Div Cent Radiol, Nara, Japan
[5] Tokushima Bunri Univ, Fac Hlth & Welf, Dept Radiol Technol, Tokushima, Kagawa, Japan
[6] Jikei Univ, Sch Med, Div Regenerat Med, Tokyo, Japan
[7] Natl Inst Adv Ind Sci & Technol, Hlth & Med Res Inst, Med Devices Res Grp, Tsukuba, Ibaraki, Japan
[8] Int Univ Hlth & Welf, Sch Hlth Sci, Dept Radiol Sci, Otawara, Tochigi, Japan
关键词
Polyethylenes - Tumors - Surface diffusion - Magnetic resonance imaging - Phantoms;
D O I
10.1007/s00723-021-01336-z
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
We aimed to examine the possibility that polyethylene glycol (PEG) phantoms can simulate apparent diffusion coefficients (ADCs) of malignant tumors and the effectiveness of PEG phantoms using three 3.0 T magnetic resonance imaging (MRI) systems. In particular, the correlations between PEG concentrations and ADC values, the validation of ADC measurement precision, and the stability and reproducibility of PEG phantom were verified. A phantom containing 0, 0.625, 1.250, 2.5, 5, 10, 20 mM PEG was assessed using three MRI systems. The endpoints comprised correlations between PEG concentrations and ADC, validation of ADC measurement precision and the stability and reproducibility of the PEG phantom. The correlation coefficients between PEG concentrations and the ADC of the three MRI systems and among the three MRI systems revealed negative (r approximate to - 1.000, P < 0.001) and positive (r approximate to 1.000, P < 0.001) correlations. The ADC(mean) of 2.5-20 mM PEG was significant (P < 0.05 t tests), and that at >= 10 mM PEG was < 1.0 x 10(-3) mm(2)/s. The %CV ranged from 1.20 to 4.62, and repeatability was confirmed by the 90% confidence interval. The maximum values for Difference(Change over time) and Difference(Pri.vs.New) were 0.20 and 0.19 x 10(-3) mm(2)/s, respectively. In this study, we found that PEG concentrations >= 10 mM are required to simulate the ADCs of malignant tumors (ADC < 1.0 x 10(-3) mm(2)/s). We also showed that the ADC value is easily controlled by adjusting PEG concentrations, and can be stably measured using our PEG phantom for at least 6 months. The PEG phantom can easily and stably simulate the ADC of malignant tumors with high reproducibility.
引用
收藏
页码:619 / 631
页数:13
相关论文
共 28 条
[11]   Recommendations towards standards for quantitative MRI (qMRI) and outstanding needs [J].
Keenan, Kathryn E. ;
Biller, Joshua R. ;
Delfino, Jana G. ;
Boss, Michael A. ;
Does, Mark D. ;
Evelhoch, Jeffrey L. ;
Griswold, Mark A. ;
Gunter, Jeffrey L. ;
Hinks, R. Scott ;
Hoffman, Stuart W. ;
Kim, Geena ;
Lattanzi, Riccardo ;
Li, Xiaojuan ;
Marinelli, Luca ;
Metzger, Gregory J. ;
Mukherjee, Pratik ;
Nordstrom, Robert J. ;
Peskin, Adele P. ;
Perez, Elena ;
Russek, Stephen E. ;
Sahiner, Berkman ;
Serkova, Natalie ;
Shukla-Dave, Amita ;
Steckner, Michael ;
Stupic, Karl F. ;
Wilmes, Lisa J. ;
Wu, Holden H. ;
Zhang, Huiming ;
Jackson, Edward F. ;
Sullivan, Daniel C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (07) :E26-E39
[12]  
Kono K, 2001, AM J NEURORADIOL, V22, P1081
[13]   A phantom for diffusion-weighted imaging of acute stroke [J].
Laubach, HJ ;
Jakob, PM ;
Loevblad, KO ;
Baird, AE ;
Bovo, MP ;
Edelman, RR ;
Warach, S .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06) :1349-1354
[14]   A phantom for diffusion-weighted MRI (DW-MRI) [J].
Lavdas, Ioannis ;
Behan, Kevin C. ;
Papadaki, Annie ;
McRobbie, Donald W. ;
Aboagye, Eric O. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (01) :173-179
[15]   High-resolution diffusion-weighted imaging with interleaved variable-density spiral acquisitions [J].
Li, TQ ;
Kim, DH ;
Moseley, ME .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) :468-475
[16]   Multi-system repeatability and reproducibility of apparent diffusion coefficient measurement using an ice-water phantom [J].
Malyarenko, Dariya ;
Galban, Craig J. ;
Londy, Frank J. ;
Meyer, Charles R. ;
Johnson, Timothy D. ;
Rehemtulla, Alnawaz ;
Ross, Brian D. ;
Chenevert, Thomas L. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (05) :1238-1246
[17]   A new phantom using polyethylene glycol as an apparent diffusion coefficient standard for MR imaging [J].
Matsuya, Ryohei ;
Kuroda, Masahiro ;
Matsumoto, Yoshitsugu ;
Kato, Hirokazu ;
Matsuzaki, Hidenobu ;
Asaumi, Junichi ;
Murakami, Jun ;
Katashima, Kazunori ;
Ashida, Masakazu ;
Sasaki, Takanori ;
Sei, Tetsuro ;
Himei, Kengo ;
Katsui, Kuniaki ;
Katayama, Norihisa ;
Takemoto, Mitsuhiro ;
Kanazawa, Susumu ;
Mimura, Seiichi ;
Oono, Seiichiro ;
Kitayama, Takuichi ;
Tahara, Seiji ;
Inamura, Keiji .
INTERNATIONAL JOURNAL OF ONCOLOGY, 2009, 35 (04) :893-900
[18]   Apparent Diffusion Coefficient Value Is Not Dependent on Magnetic Resonance Systems and Field Strength Under Fixed Imaging Parameters in Brain [J].
Ogura, Akio ;
Tamura, Takayuki ;
Ozaki, Masanori ;
Doi, Tsukasa ;
Fujimoto, Koji ;
Miyati, Tosiaki ;
Ito, Yukiko ;
Maeda, Fumie ;
Tarewaki, Hiroyuki ;
Takahashi, Mitsuyuki .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) :760-765
[19]   Imaging parameter effects in apparent diffusion coefficient determination of magnetic resonance imaging [J].
Ogura, Akio ;
Hayakawa, Katsumi ;
Miyati, Tosiaki ;
Maeda, Fumie .
EUROPEAN JOURNAL OF RADIOLOGY, 2011, 77 (01) :185-188
[20]   Toward Precision and Reproducibility of Diffusion Tensor Imaging: A Multicenter Diffusion Phantom and Traveling Volunteer Study [J].
Palacios, E. M. ;
Martin, A. J. ;
Boss, M. A. ;
Ezekiel, F. ;
Chang, Y. S. ;
Yuh, E. L. ;
Vassar, M. J. ;
Schnyer, D. M. ;
MacDonald, C. L. ;
Crawford, K. L. ;
Irimia, A. ;
Toga, A. W. ;
Mukherjee, P. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (03) :537-545