Evaluation of a Polyethylene Glycol Phantom for Measuring Apparent Diffusion Coefficients Using Three 3.0 T MRI Systems

被引:2
作者
Sato, Eisuke [1 ]
Fukuzawa, Kei [2 ]
Takashima, Hiroyuki [3 ]
Yamatani, Yuya [4 ]
Takatsu, Yasuo [5 ]
Hata, Junichi [6 ]
Hikishima, Keigo [7 ]
Miwa, Kenta [8 ]
机构
[1] Juntendo Univ, Fac Hlth Sci, Dept Radiol Technol, Bunkyo Ku, 3-2-12 Hongo, Tokyo 1130033, Japan
[2] Toranomon Gen Hosp, Dept Radiol Technol, Tokyo, Japan
[3] Sapporo Med Univ Hosp, Div Radiol & Nucl Med, Sapporo, Hokkaido, Japan
[4] Nara Med Univ Hosp, Div Cent Radiol, Nara, Japan
[5] Tokushima Bunri Univ, Fac Hlth & Welf, Dept Radiol Technol, Tokushima, Kagawa, Japan
[6] Jikei Univ, Sch Med, Div Regenerat Med, Tokyo, Japan
[7] Natl Inst Adv Ind Sci & Technol, Hlth & Med Res Inst, Med Devices Res Grp, Tsukuba, Ibaraki, Japan
[8] Int Univ Hlth & Welf, Sch Hlth Sci, Dept Radiol Sci, Otawara, Tochigi, Japan
关键词
Polyethylenes - Tumors - Surface diffusion - Magnetic resonance imaging - Phantoms;
D O I
10.1007/s00723-021-01336-z
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
We aimed to examine the possibility that polyethylene glycol (PEG) phantoms can simulate apparent diffusion coefficients (ADCs) of malignant tumors and the effectiveness of PEG phantoms using three 3.0 T magnetic resonance imaging (MRI) systems. In particular, the correlations between PEG concentrations and ADC values, the validation of ADC measurement precision, and the stability and reproducibility of PEG phantom were verified. A phantom containing 0, 0.625, 1.250, 2.5, 5, 10, 20 mM PEG was assessed using three MRI systems. The endpoints comprised correlations between PEG concentrations and ADC, validation of ADC measurement precision and the stability and reproducibility of the PEG phantom. The correlation coefficients between PEG concentrations and the ADC of the three MRI systems and among the three MRI systems revealed negative (r approximate to - 1.000, P < 0.001) and positive (r approximate to 1.000, P < 0.001) correlations. The ADC(mean) of 2.5-20 mM PEG was significant (P < 0.05 t tests), and that at >= 10 mM PEG was < 1.0 x 10(-3) mm(2)/s. The %CV ranged from 1.20 to 4.62, and repeatability was confirmed by the 90% confidence interval. The maximum values for Difference(Change over time) and Difference(Pri.vs.New) were 0.20 and 0.19 x 10(-3) mm(2)/s, respectively. In this study, we found that PEG concentrations >= 10 mM are required to simulate the ADCs of malignant tumors (ADC < 1.0 x 10(-3) mm(2)/s). We also showed that the ADC value is easily controlled by adjusting PEG concentrations, and can be stably measured using our PEG phantom for at least 6 months. The PEG phantom can easily and stably simulate the ADC of malignant tumors with high reproducibility.
引用
收藏
页码:619 / 631
页数:13
相关论文
共 28 条
[1]   Evaluation of giant cell tumors by diffusion weighted imaging-fractional ADC analysis [J].
Ashikyan, Oganes ;
Chalian, M. ;
Moore, D. ;
Xi, Y. ;
Pezeshk, P. ;
Chhabra, A. .
SKELETAL RADIOLOGY, 2019, 48 (11) :1765-1773
[2]   Diffusion tensor imaging (DTI)-based white matter mapping in brain research: A review [J].
Assaf, Yaniv ;
Pasternak, Ofer .
JOURNAL OF MOLECULAR NEUROSCIENCE, 2008, 34 (01) :51-61
[3]  
Bateman Mathew, 2017, Top Magn Reson Imaging, V26, P77, DOI 10.1097/RMR.0000000000000124
[4]   Diffusion Coefficient Measurement Using a Temperature-Controlled Fluid for Quality Control in Multicenter Studies [J].
Chenevert, Thomas L. ;
Galban, Craig J. ;
Ivancevic, Marko K. ;
Rohrer, Susan E. ;
Londy, Frank J. ;
Kwee, Thomas C. ;
Meyer, Charles R. ;
Johnson, Timothy D. ;
Rehemtulla, Alnawaz ;
Ross, Brian D. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (04) :983-987
[5]   Developing a quality control protocol for diffusion imaging on a clinical MRI system [J].
Delakis, I ;
Moore, EM ;
Leach, MO ;
De Wilde, JP .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (08) :1409-1422
[6]   Development of an MRI Phantom for Diffusion-Weighted Imaging with Independent Adjustment of Apparent Diffusion Coefficient Values and T2 Relaxation Times [J].
Gatidis, Sergios ;
Schmidt, Holger ;
Martirosian, Petros ;
Schwenzer, Nina F. .
MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (02) :459-463
[7]   Malignant astrocytic tumors: Clinical importance of apparent diffusion coefficient in prediction of grade and prognosis [J].
Higano, Shuichi ;
Yun, Xia ;
Kumabe, Toshihiro ;
Watanabe, Mika ;
Mugikura, Shunji ;
Umetsu, Atsushi ;
Sato, Akihiro ;
Yamada, Takayuki ;
Takahashi, Shoki .
RADIOLOGY, 2006, 241 (03) :839-846
[8]   Comparison of diffusion anisotropy measurements in combination with the flair-technique [J].
Hirsch, JG ;
Bock, M ;
Essig, M ;
Schad, LR .
MAGNETIC RESONANCE IMAGING, 1999, 17 (05) :705-716
[9]   Development of a temperature-controlled phantom for magnetic resonance quality assurance of diffusion, dynamic, and relaxometry measurements [J].
Jerome, Neil P. ;
Papoutsaki, Marianthi-Vasiliki ;
Orton, Matthew R. ;
Parkes, Harold G. ;
Winfield, Jessica M. ;
Boss, Michael A. ;
Leach, Martin O. ;
deSouza, Nandita M. ;
Collins, David J. .
MEDICAL PHYSICS, 2016, 43 (06) :2998-3007
[10]   Apparent diffusion coefficient measurements on a novel diffusion weighted MRI phantom utilizing EPI and HASTE sequences [J].
Kalaitzakis, Georgios ;
Boursianis, Themistoklis ;
Gourzoulidis, Georgios ;
Gourtsoyianni, Sofia ;
Lymperopoulou, Georgia ;
Marias, Konstantinos ;
Karantanas, Apostolos ;
Maris, Thomas G. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 73 :179-189