Electrogenerated chemiluminescence biosensing method for the discrimination of DNA hydroxymethylation and assay of the β-glucosyltransferase activity

被引:22
|
作者
Sun, Huiping [1 ]
Ma, Shangxian [1 ]
Li, Yan [1 ]
Qi, Honglan [2 ]
Ning, Xiaohui [1 ]
Zheng, Jianbin [1 ]
机构
[1] Northwest Univ, Inst Analyt Sci, Shaanxi Prov Key Lab Electroanalyt Chem, Xian 710069, Shaanxi, Peoples R China
[2] Shaanxi Normal Univ, Sch Chem & Chem Engn, Key Lab Analyt Chem Life Sci Shaanxi Prov, Xian 710062, Peoples R China
来源
关键词
Electrogenerated chemiluminescence; DNA hydroxymethylation; beta-glucosyltransferase endonuclease; Tris(2; 2; '-bipyridyl)ruthenium; 5-HYDROXYMETHYLCYTOSINE; ELECTROCHEMILUMINESCENCE; 5-METHYLCYTOSINE; BASE; METHYLATION; GENOMES; BRAIN; FILMS;
D O I
10.1016/j.bios.2015.11.068
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An electrogenerated chemiluminescence (ECL) biosensing method for highly sensitive discrimination of DNA hydroxymethylation and assay of the beta-glucosyltransferase (beta-GT) activity was developed. The ECL biosensing electrode was fabricated by gold nanoparticles (AuNPs)/Nafion film, and then, tris(2, 2'-ri-pyridine) dichlororuthenium(II) (Ru(bpy)(3)(2+)) was electrostatically adsorbed into the AuNPs/Nafion film, finally, the hydroxymethylated double-stranded DNA (ds-DNA)-tagged with ferrocene was self-assembled onto the surface of the AuNPs. When beta-GT and uridine diphosphoglucose (UDP-Glu) were introduced, the hydroxymethylcytosine residues within 5'-CCGG-3' of ds-DNA on the biosensing electrode were glucosylated. After the glucosylated biosensing electrode was treated by Mspl endonuclease, the unglucosylated hydroxymethylcytosine was cleaved, leading to the quencher leaving the electrode, resulting in an increased ECL signal. For the ECL biosensing method, it showed an extremely low detection limit of 0.04 U/mL for beta-GT, and offered a good discrimination toward cytosine, 5-methylcytosine, and 5-hydroxymethylcytosine. This work demonstrates that the combination of the enzyme-linkage reactions with the highly sensitive ECL method is a promising strategy for the discrimination of DNA hydroxymethylation, assay of the activity of beta-GT, and evaluation of the capability of inhibitors for the beta-GT. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 44 条
  • [41] Comparative Study of the DNA-Damaging Activity of Epichlorohydrin Using Escherichia coli Biosensors and the Comet Assay Method in Mice
    Ordzhonikidze, K. G.
    Igonina, E., V
    Zhoshibekova, B. S.
    Abilev, S. K.
    RUSSIAN JOURNAL OF GENETICS, 2021, 57 (09) : 1035 - 1041
  • [42] Comparative Study of the DNA-Damaging Activity of Epichlorohydrin Using Escherichia coli Biosensors and the Comet Assay Method in Mice
    K. G. Ordzhonikidze
    E. V. Igonina
    B. S. Zhoshibekova
    S. K. Abilev
    Russian Journal of Genetics, 2021, 57 : 1035 - 1041
  • [43] A new method for the in situ assay of α-glucosidase activity and inhibitor screening through an enzyme substrate-mediated DNA hybridization chain reaction
    Yue, Xiquan
    Su, Lihong
    Chen, Xu
    Liu, Junfeng
    Zheng, Longpo
    Zhang, Juan
    NEW JOURNAL OF CHEMISTRY, 2019, 43 (24) : 9458 - 9465
  • [44] Assay method for Escherichia coli photolyase activity using single-strand cis-syn cyclobutane pyrimidine dimer DNA as substrate
    Nakayama, T
    Todo, T
    Notsu, S
    Nakazono, M
    Zaitsu, K