Electrogenerated chemiluminescence biosensing method for the discrimination of DNA hydroxymethylation and assay of the β-glucosyltransferase activity

被引:22
|
作者
Sun, Huiping [1 ]
Ma, Shangxian [1 ]
Li, Yan [1 ]
Qi, Honglan [2 ]
Ning, Xiaohui [1 ]
Zheng, Jianbin [1 ]
机构
[1] Northwest Univ, Inst Analyt Sci, Shaanxi Prov Key Lab Electroanalyt Chem, Xian 710069, Shaanxi, Peoples R China
[2] Shaanxi Normal Univ, Sch Chem & Chem Engn, Key Lab Analyt Chem Life Sci Shaanxi Prov, Xian 710062, Peoples R China
关键词
Electrogenerated chemiluminescence; DNA hydroxymethylation; beta-glucosyltransferase endonuclease; Tris(2; 2; '-bipyridyl)ruthenium; 5-HYDROXYMETHYLCYTOSINE; ELECTROCHEMILUMINESCENCE; 5-METHYLCYTOSINE; BASE; METHYLATION; GENOMES; BRAIN; FILMS;
D O I
10.1016/j.bios.2015.11.068
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An electrogenerated chemiluminescence (ECL) biosensing method for highly sensitive discrimination of DNA hydroxymethylation and assay of the beta-glucosyltransferase (beta-GT) activity was developed. The ECL biosensing electrode was fabricated by gold nanoparticles (AuNPs)/Nafion film, and then, tris(2, 2'-ri-pyridine) dichlororuthenium(II) (Ru(bpy)(3)(2+)) was electrostatically adsorbed into the AuNPs/Nafion film, finally, the hydroxymethylated double-stranded DNA (ds-DNA)-tagged with ferrocene was self-assembled onto the surface of the AuNPs. When beta-GT and uridine diphosphoglucose (UDP-Glu) were introduced, the hydroxymethylcytosine residues within 5'-CCGG-3' of ds-DNA on the biosensing electrode were glucosylated. After the glucosylated biosensing electrode was treated by Mspl endonuclease, the unglucosylated hydroxymethylcytosine was cleaved, leading to the quencher leaving the electrode, resulting in an increased ECL signal. For the ECL biosensing method, it showed an extremely low detection limit of 0.04 U/mL for beta-GT, and offered a good discrimination toward cytosine, 5-methylcytosine, and 5-hydroxymethylcytosine. This work demonstrates that the combination of the enzyme-linkage reactions with the highly sensitive ECL method is a promising strategy for the discrimination of DNA hydroxymethylation, assay of the activity of beta-GT, and evaluation of the capability of inhibitors for the beta-GT. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 97
页数:6
相关论文
共 26 条
  • [21] Electrogenerated chemiluminescence peptide-based biosensing method for cardiac troponin I using peptide-integrating Ru(bpy)32+-functionalized gold nanoparticles as nanoprobe
    Dong, Manman
    Li, Min
    Qi, Honglan
    Li, Zhejian
    Gao, Qiang
    Zhang, Chengxiao
    GOLD BULLETIN, 2015, 48 (1-2): : 21 - 29
  • [22] Electrogenerated chemiluminescence peptide-based biosensing method for cardiac troponin I using peptide-integrating Ru(bpy)32+-functionalized gold nanoparticles as nanoprobe
    Manman Dong
    Min Li
    Honglan Qi
    Zhejian Li
    Qiang Gao
    Chengxiao Zhang
    Gold Bulletin, 2015, 48 : 21 - 29
  • [23] Label-Free Electrogenerated Chemiluminescence Aptasensing Method for Highly Sensitive Determination of Dopamine via Target- Induced DNA Conformational Change
    Zhang, Danyang
    Qian, Manping
    Yang, Xiaolin
    Zhang, Chengxiao
    Qi, Hetong
    Qi, Honglan
    ANALYTICAL CHEMISTRY, 2023, 95 (13) : 5500 - 5506
  • [24] Signal-off/on electrogenerated chemiluminescence deoxyribosensors for assay of early lung cancer biomarker (NAP2) based on target-caused DNA charge transfer
    Chen, Yu
    Sun, Lina
    Qiao, Xinrui
    Zhang, Yuanfu
    Li, Yan
    Ma, Fen
    ANALYTICA CHIMICA ACTA, 2020, 1103 : 67 - 74
  • [25] Highly sensitive photoelectrochemical assay for DNA methyltransferase activity and inhibitor screening by exciton energy transfer coupled with enzyme cleavage biosensing strategy
    Shen, Qingming
    Han, Li
    Fan, Gaochao
    Abdel-Halim, E. S.
    Jiang, Liping
    Zhu, Jun-Jie
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 449 - 455
  • [26] Label-free and immobilization-free photoelectrochemical biosensing strategy using methylene blue in homogeneous solution as signal probe for facile DNA methyltransferase activity assay
    Hou, Ting
    Xu, Ningning
    Wang, Wenxiao
    Ge, Lei
    Li, Feng
    BIOSENSORS & BIOELECTRONICS, 2019, 141