On-Site Application of Novel Partial Discharge Monitoring Scheme for Rotating Machine

被引:0
|
作者
Kim, Yong Joo [1 ]
Hong, Seok Hoon [1 ]
Kong, Tae Sik [2 ]
Kim, Hee Dong [2 ]
机构
[1] Chung Ang Univ, Energy Syst Engn Dept, Seoul 156756, South Korea
[2] KEPCO Res Inst, Technol Expert Ctr, Daejeon, South Korea
来源
2015 IEEE ELECTRICAL INSULATION CONFERENCE (EIC) | 2015年
关键词
partial discharge; stator bar; on-line monitoring; external noise disrimination; partial discharge locating technique;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Authors' previous work had introduced a novel on-line partial discharge monitoring sensor CSC (Capacitive Slot Coupler), which frequency band was claimed to be between 100 kHz and 20 MHz. However, after intensive laboratory work and on-site experiment, it was found that frequency characteristic of CSC PD sensor could be widely extended from 100 kHz up to 250 MHz. Furthermore, from on-site experiment for small motor, it suggests that the novel CSC PD sensor could be adopted in effectively discriminating the various external noises and locating PD activity. In addition, it is confirmed that partial discharge signals detected by CSC is compatibly adapted to the commercial on-line PD monitoring systems.
引用
收藏
页码:85 / 88
页数:4
相关论文
共 37 条
  • [31] Condition Monitoring Based on Partial Discharge Diagnostics Using Machine Learning Methods: A Comprehensive State-of-the-Art Review
    Lu, Shibo
    Chai, Hua
    Sahoo, Animesh
    Phung, B. T.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (06) : 1861 - 1888
  • [32] Novel Dual-Band Cavity-Backed Antenna Design and Its Application to Simultaneous RFID Communications and Partial Discharge Monitoring of High Voltage Facilities
    Zhang, Wen-Hai
    Tam, Kam-Weng
    Lu, Wen-Jun
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XX), 2017, 42 : 19 - 24
  • [33] Application of distributed partial discharge on-line monitoring technology in Shanghai 500 kV XLPE power cable line
    Jiang, Yun
    Zhou, Yunjie
    Gaodianya Jishu/High Voltage Engineering, 2015, 41 (04): : 1249 - 1256
  • [34] A NOVEL SOLUTION FOR THE RELIABLE ONLINE PARTIAL DISCHARGE MONITORING (OLPD) OF VSD-OPERATED EX/ATEX HV MOTORS
    Renforth, Lee
    Giussani, Riccardo
    Knutsen, Terje
    Aardal, Brynjar
    Kjenner, Tom-Erik
    2016 PETROLEUM AND CHEMICAL INDUSTRY CONFERENCE EUROPE (PCIC EUROPE), 2016,
  • [35] Application of the integrated AE and HFCT sensors for online Dry-type Transformer Partial Discharge Monitoring. Case study
    Tikakosol, Kitimasak
    Tanitteerapan, Tanes
    Mungkung, Narong
    PRZEGLAD ELEKTROTECHNICZNY, 2021, 97 (02): : 105 - 111
  • [36] Intelligent Monitoring System Based on Optical Fiber Acoustic Emission Sensor and Its Application in Partial Discharge Diagnosis of Gas-insulated Switchgear
    Hou, Shiqi
    Qin, Yongrui
    Gao, Jiaxin
    Lyu, Fuyong
    Li, Xuefeng
    SENSORS AND MATERIALS, 2021, 33 (04) : 1127 - 1136
  • [37] A novel semi-supervised power transformer defect monitoring technique using unreliable pseudo-labels with highly imbalanced partial discharge signals
    Rajamayil, Manimala
    Basharan, Vigneshwaran
    ELECTRICAL ENGINEERING, 2024, : 4939 - 4957