Novel fabrication of immunochromatographic assay based on up conversion phosphors for sensitive detection of clenbuterol

被引:67
作者
Wang, Peilong [1 ,2 ]
Wang, Ruiguo [1 ,2 ]
Zhang, Wei [1 ,2 ]
Su, Xiaoou [1 ,2 ]
Luo, Haifeng [3 ]
机构
[1] Minist Agr, Key Lab Agrifood Safety & Qual, Beijing 100081, Peoples R China
[2] China Agr Acad Sci, Inst Qual Stand & Testing Technol Agr Prod, Beijing 100081, Peoples R China
[3] Beijing Hotgen Biol Technol Co LTD, Beijing 102600, Peoples R China
关键词
Clenbuterol; Up conversion phosphors; Immunochromatographic sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; BETA-AGONIST RESIDUES; FLOW TEST STRIP; URINE; NANOPARTICLES; FEED; IMMUNOASSAY; SALBUTAMOL; BOVINE;
D O I
10.1016/j.bios.2015.10.053
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel and ultra sensitive immunochromatographic assay sensor (ICA) based on up conversion phosphor (UCP) for quantitative detection of clenbuterol (CL) was developed. Monoclonal antibody against CL was labeled with UCP beads. The detection strategy is based on competitive immunoreaction between CL antibodies conjugated to UCP beads and CL or CL antigen on the UCP-ICA sensor. It enables ultra sensitive detection of CL in one single test without complicated sample preparation. Sensing results can be obtained within 10 min. Under optimized conditions, visual limit of detection (vLOD) of UCP-ICA for CL was 0.1 ng/mL. Calculated LOD (CLOD) for CL, as low as 0.01 ng/mL, could be achieved with the UCP-ICA sensor. Recoveries of CL in various sample matrixes ranged from 73.0% to 92.2% and relative standard deviations (RSD) were below 12%. The assay was evaluated with spiked and real samples and the results were compared with liquid chromatography-tandem mass. The developed novel assay method based on UCP could be a potential alternative format for on site and rapid detection of CL as well as other illegal drugs. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:866 / 870
页数:5
相关论文
共 28 条
[1]   Determination of clenbuterol in human urine by GC-MS-MS-MS:: confirmation analysis in antidoping control [J].
Amendola, L ;
Colamonici, C ;
Rossi, F ;
Botrè, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01) :7-16
[2]  
Ang LY, 2011, NANOMEDICINE-UK, V6, P1273, DOI [10.2217/NNM.11.108, 10.2217/nnm.11.108]
[3]   Coupling purification and in situ immobilization process of monoclonal antibodies to clenbuterol for immunosensor application [J].
Cao, Hui ;
Yuan, Min ;
Wang, Lili ;
Yu, Jingsong ;
Xu, Fei .
ANALYTICAL BIOCHEMISTRY, 2015, 476 :59-66
[4]   A dual-responsive fluorescence method for the detection of clenbuterol based on BSA-protected gold nanoclusters [J].
Cao, Xueling ;
Li, Hongwei ;
Lian, Lili ;
Xu, Na ;
Lou, Dawei ;
Wu, Yuqing .
ANALYTICA CHIMICA ACTA, 2015, 871 :43-50
[5]   Up-converting phosphor technology-based lateral flow assay for detection of Schistosoma circulating anodic antigen in serum [J].
Corstjens, Paul L. A. M. ;
van Lieshout, Lisette ;
Zuiderwijk, Michel ;
Kornelis, Dieuwke ;
Tanke, Hans J. ;
Deelder, Andre M. ;
van Dam, Govert J. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) :171-176
[6]   Combined solid-phase microextraction and high-performance liquid chromatography with ultroviolet detection for simultaneous analysis of clenbuterol, salbutamol and ractopamine in pig samples [J].
Du, Wei ;
Zhang, Siruo ;
Fu, Qiang ;
Zhao, Gang ;
Chang, Chun .
BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (12) :1775-1781
[7]   Development of a label-free electrochemical immunosensor based on carbon nanotube for rapid determination of clenbuterol [J].
He, Pingli ;
Wang, Zongyi ;
Zhang, Liying ;
Yang, Wenjun .
FOOD CHEMISTRY, 2009, 112 (03) :707-714
[8]   Development of Immunochromatographic Assay for the On-site Detection of Salbutamol [J].
Khamta, Yaowapa ;
Pattarawarapan, Mookda ;
Nangola, Sawitree ;
Tayapiwatana, Chatchai .
JOURNAL OF IMMUNOASSAY & IMMUNOCHEMISTRY, 2009, 30 (04) :441-456
[9]   Integrated microfluidic immunoassay for the rapid determination of clenbuterol [J].
Kong, Jing ;
Jiang, Lei ;
Su, Xiaoou ;
Qin, Jianhua ;
Du, Yuguang ;
Lin, Bingcheng .
LAB ON A CHIP, 2009, 9 (11) :1541-1547
[10]   Multiresidue analysis of beta-agonists in bovine and porcine urine, feed and hair using liquid chromatography electrospray ionisation tandem mass spectrometry [J].
Nielen, M. W. F. ;
Lasaroms, J. J. P. ;
Essers, M. L. ;
Oosterink, J. E. ;
Meijer, T. ;
Sanders, M. B. ;
Zuidema, T. ;
Stolker, A. A. M. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (01) :199-210