Interobserver and Intraobserver Reliability of Cobb Angle Measurement: Endplate Versus Pedicle as Bony Landmarks for Measurement: A Statistical Analysis

被引:17
作者
Mehta, Satyen S. [1 ]
Modi, Hitesh N. [1 ]
Srinivasalu, Santhana [1 ]
Chen, Ting [1 ]
Suh, Seung Woo [1 ]
Yang, Jae-Hyuk [1 ]
Song, Hae Ryong [2 ]
机构
[1] Korea Univ, Guro Hosp, Scoliosis Res Inst, Dept Orthopaed, Seoul 152703, South Korea
[2] Korea Univ, Guro Hosp, Rare Dis Inst, Dept Orthopaed, Seoul 152703, South Korea
关键词
Cobb angle; pedicle; endplate; inter/intraobserver variability; ADOLESCENT IDIOPATHIC SCOLIOSIS; CLINICAL MEASUREMENT; BODY HEIGHT; RADIOGRAPHS;
D O I
10.1097/BPO.0b013e3181b72550
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The Cobb-Lippman technique measures the curve severity by measuring the angle between the upper and lower endplates of the upper-end and lower-end vertebrae, respectively, using pedicles to measure the angle when they are better visualized than the endplates. Vertebral endplates in younger children provide less distinct bony landmarks and pedicles may be more easily identifiable in these children. The purpose of this study is to evaluate the reliability of the pedicle method of the Cobb angle measurement and compare it with the conventional endplate method of measurement. Methods: Three hundred and eighteen whole spine preoperative anteroposterior radiograms of children with varying degrees of idiopathic scoliosis involving the thoracic spine were evaluated. These radiograms were grouped based on the child's age (< 7 y, 7 to 10 y and > 10 y), the position of the upper-end vertebra (upper-end vertebra at or above T5 and upper-end vertebra caudal to T5), and based on curve severity (mild, < 20 degrees; moderate 20 to 40 degrees, and severe > 40 degrees). Three observers independently examined the radiograms using the endplate method and the pedicle method 3 times each using the digitized computer system. Both intraobserver and interobserver agreements were accessed by calculating the intraclass correlation coefficient (ICCC). In addition, a Bland-Altman plot was made in which the strength of the relationship between the score differences and their mean was indicated by the slope of a regression line. Results: The single ICCC values were better for all observers for < 7-year age group using the pedicle method, indicating lesser intraobserver variability. The average ICCC values, indicating interobserver variability, were similar for all age groups. All the ICCC values lay in the excellent or substantial group. Tests for significance showed no significant difference between the 2 methods of measurement. Conclusions: Differences in measurement values with the pedicle method and end-plate method of measurement of the Cobb angle are not statistically significant. Either method can be used for measurement when using a computer-digitized system, which may have helped to minimize measurement discrepancies between these 2 methods.
引用
收藏
页码:749 / 754
页数:6
相关论文
共 16 条
  • [1] [Anonymous], BIOMETRICS
  • [2] COMPARING 2 METHODS OF CLINICAL MEASUREMENT - A PERSONAL HISTORY
    BLAND, JM
    ALTMAN, DG
    [J]. INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1995, 24 : S7 - S14
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION
    CARMAN, DL
    BROWNE, RH
    BIRCH, JG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) : 328 - 333
  • [5] The reliability of quantitative analysis on digital images of the scoliotic spine
    Cheung, J
    Wever, DJ
    Veldhuizen, AG
    Klein, JP
    Verdonck, B
    Nijlunsing, R
    Cool, JC
    Van Horn, JR
    [J]. EUROPEAN SPINE JOURNAL, 2002, 11 (06) : 535 - 542
  • [6] Intra-observer reproducibility and interobserver reliability of the radiographic parameters in the Spinal Deformity Study Group's AIS Radiographic Measurement Manual
    Dang, NR
    Moreau, MJ
    Hill, DL
    Mahood, JK
    Raso, J
    [J]. SPINE, 2005, 30 (09) : 1064 - 1069
  • [7] DAWSON EG, 1978, CLIN ORTHOP RELAT R, P151
  • [8] REPRODUCIBILITY AND RESPONSIVENESS OF HEALTH-STATUS MEASURES - STATISTICS AND STRATEGIES FOR EVALUATION
    DEYO, RA
    DIEHR, P
    PATRICK, DL
    [J]. CONTROLLED CLINICAL TRIALS, 1991, 12 (04): : S142 - S158
  • [9] Comparison of manual and digital measurements in adolescent idiopathic scoliosis
    Kuklo, Timothy R.
    Potter, Benjamin K.
    Schroeder, Teresa M.
    O'Brien, Michael F.
    [J]. SPINE, 2006, 31 (11) : 1240 - 1246
  • [10] VARIABILITY IN COBB ANGLE MEASUREMENTS IN CHILDREN WITH CONGENITAL SCOLIOSIS
    LODER, RT
    URQUHART, A
    STEEN, H
    GRAZIANO, G
    HENSINGER, RN
    SCHLESINGER, A
    SCHORK, MA
    SHYR, Y
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77 (05): : 768 - 770