Behavior of plate load tests on soil layers, improved with cement and fiber

被引:105
作者
Consoli, NC
Vendrusco, MRA
Prietto, PDM
机构
[1] Univ Fed Rio Grande Sul, Dept Civil Engn, BR-90035190 Porto Alegre, RS, Brazil
[2] Catholic Univ Pelotas, Sch Engn & Architecture, BR-96010000 Pelotas, RS, Brazil
关键词
fiber reinforced materials; cements; in situ tests; laboratory tests; plates; loads;
D O I
10.1061/(ASCE)1090-0241(2003)129:1(96)
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The load-settlement response from three plate load tests (300 mm diameter, 25.4 mm thick) carried out directly on a homogeneous residual soil stratum, as well as on a layered system formed by two different top layers (300 mm thick)-sand-cement and sand-cement fiber-overlaying the residual soil stratum, is discussed in this technical note. The utilization of a cemented top layer increased bearing capacity, reduced displacement at failure, and changed soil behavior to a noticeable brittle behavior. After maximum load, the bearing capacity dropped towards approximately the same value found for the plate test carried out directly on the residual soil. The addition of fiber to the cemented top layer maintained roughly the same bearing capacity but changed the postfailure behavior to a ductile behavior. A punching failure mechanism was observed in the field for the load test bearing on the sand-cement top layer, with tension cracks being formed from the bottom to the top of the layer. A completely distinct mechanism was observed in the case of the sand-cement-fiber top layer, the failure occurring through the formation of a thick shear band around the border of the plate, which allowed the stresses to spread through a larger area over the residual soil stratum.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 16 条
[1]  
[Anonymous], P 8 EUR C SOIL MECH
[2]  
[Anonymous], THESIS FEDERAL U RIO
[3]  
[Anonymous], THESIS FEDERAL U RIO
[4]  
ASTM, 1998, D119494 ASTM
[5]  
Clayton C.R. I., 1989, GEOTECH TEST J, V12, P69, DOI DOI 10.1520/GTJ10676J
[6]  
CLAYTON CRI, 1986, GEOTECHNIQUE, V25, P657
[7]   Interpretation of plate load tests on residual soil site [J].
Consoli, NC ;
Schnaid, F ;
Milititsky, J .
JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 1998, 124 (09) :857-867
[8]  
CONSOLI NC, 1997, P 14 INT C SOIL MECH, P783
[9]  
LAROCHELLE P, 1988, P S ADV TRIAX TEST S, P715
[10]  
MASWOSWE J, 1985, THESIS U LONDON