Ball versus Locator(R) Attachments: A Retrospective Study on Prosthetic Maintenance and Effect on Oral-Health-Related Quality of Life

被引:10
作者
Brandt, Silvia [1 ]
Lauer, Hans-Christoph [2 ]
Fehrenz, Michael [3 ]
Gueth, Jan-Frederik [1 ]
Romanos, Georgios [4 ,5 ]
Winter, Anna [6 ]
机构
[1] Goethe Univ Frankfurt, Dept Prosthodont, Theodor Stern Kai 7, D-60596 Frankfurt, Germany
[2] Private Practice B2V Dr Brandt & Colleagues, D-61118 Bad Vilbel, Germany
[3] Saarland Univ Hosp, Clin Oral & Maxillofacial Surg, Kirrberger Str 100, D-66424 Homburg, Germany
[4] SUNY Stony Brook, Sch Dent Med, Dept Periodontol, Rockland Hall 106, Stony Brook, NY 11794 USA
[5] Goethe Univ Frankfurt, Dept Oral Surg & Implant, Theodor Stern Kai 7, D-60596 Frankfurt, Germany
[6] Julius Maximilian Univ Wurzburg, Dept Prosthodont, Pleicherwall 2, D-97070 Wurzburg, Germany
关键词
attachment; ball; locator; overdenture; OHRQoL; OHIP-G14; IMPLANT-RETAINED OVERDENTURES; MANDIBULAR OVERDENTURES; CHEWING EFFICIENCY; COMPLETE DENTURES; MASSETER MUSCLE; RETENTION; SATISFACTION; MAXILLARY; SYSTEMS;
D O I
10.3390/ma14041051
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Locator(R) and ball attachments are well-established systems to attach overdentures to two inter-foraminal implants. This study aimed to evaluate differences between the two systems regarding prosthetic maintenance and patients' oral-health-related quality of life (OHRQoL). Dental records of patients with a mandibular implant-retained overdenture were retrospectively analyzed. Prosthetic maintenance measures involving the denture suprastructure and attachment matrix and patrix were analyzed. Furthermore, the Oral Health Impact Profile-G14 (OHIP-G14) was used to evaluate OHRQoL. Results were analyzed by means of Kaplan-Meier analysis and Student's t- and log-rank tests. The records of 122 patients were evaluated. Kaplan-Meier survival analysis revealed a significant difference between ball attachments (Group B; n patients = 47) and Locator(R) attachments (Group L; n patients = 75) regarding the occurrence of denture fractures (p < 0.001) and events affecting the matrix (p = 0.028) and patrix (p = 0.030). Group L had a significantly lower total OHIP-G14 score than Group B (p = 0.002). The most common maintenance events were matrix-related and denture relining for both attachment systems. Group B required more maintenance measures than Group L. Moreover, patients in Group L had better OHRQoL than patients in Group B.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 43 条
[1]   Assessment of factors influencing oral health-related quality of life (OHRQoL) of patients with removable dental prosthesis [J].
Al Deeb, Modhi ;
Abduljabbar, Tariq ;
Vohra, Fahim ;
Zafar, Muhammad S. ;
Hussain, Mudassir .
PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2020, 36 (02) :213-218
[2]   Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study [J].
Aroso, Carlos ;
Silva, Antonio Sergio ;
Ustrell, Raul ;
Mendes, Jose Manuel ;
Braga, Ana Cristina ;
Berastegui, Esther ;
Escuin, Tomas .
JOURNAL OF ADVANCED PROSTHODONTICS, 2016, 8 (01) :21-29
[3]   Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses [J].
Brandt, Silvia ;
Brandt, Jan ;
Ketabi, Ali-Reza ;
Lauer, Hans-Christoph ;
Kunzmann, Anna .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (02) :763-770
[4]   The effects of two attachment types on the stresses introduced to the mandibular residual ridge: A 3D finite element analysis [J].
Dashti, Mohammad Hossein ;
Atashrazm, Parsa ;
Emadi, Mehdi Imani ;
Mishaeel, Shiva ;
Banava, Sepideh .
QUINTESSENCE INTERNATIONAL, 2013, 44 (08) :585-590
[5]   Chewing efficiency and electromyographic activity of masseter muscle with three designs of implant-supported mandibular overdentures. A cross-over study [J].
Elsyad, Moustafa A. ;
Hegazy, Salah A. F. ;
Hammouda, Nelly I. ;
Al-Tonbary, Gilan Y. ;
Habib, Ahmed A. .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (06) :742-748
[6]   Locator Versus Bar Attachment Effect on the Retention and Stability of Implant-Retained Maxillary Overdenture: An In Vitro Study [J].
ELsyad, Moustafa Abdou ;
Dayekh, Mahmoud Abdehamid ;
Khalifa, Ahmed Khalifa .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02) :E627-E636
[7]   Masticatory function with ball and resilient telescopic anchors of mandibular implant-retained overdentures: A crossover study [J].
Elsyad, Moustafa Abdou ;
Shawky, Ahmad Fathalla .
QUINTESSENCE INTERNATIONAL, 2017, 48 (08) :615-623
[8]   Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures [J].
ELsyad, Moustafa Abdou ;
Errabti, Hatem Mokhtar ;
Mustafa, Aisha Zakaria .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (08) :656-664
[9]   The Change in Retentive Values of Locator Attachments and Hader Clips over Time [J].
Evtimovska, Elizabeta ;
Masri, Radi ;
Driscoll, Carl F. ;
Romberg, Elaine .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2009, 18 (06) :479-483
[10]   Interventions of Maintain Locator-Retained Mandibular Overdentures on Both External Hex and Internal Connection Implants: A Retrospective Study [J].
Fernandez-Estevan, Lucia ;
Montero, Javier ;
Selva Otaolaurruchi, Eduardo J. ;
Sola Ruiz, Maria Fernanda .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) :838-846