Distribution and related factors of corneal regularity and posterior corneal astigmatism in cataract patients

被引:6
|
作者
Li, Chen [1 ]
Zhang, Jiaju [1 ]
Yin, Xue [1 ]
Li, Jianqing [1 ]
Cao, Yihong [1 ]
Lu, Peirong [1 ]
机构
[1] Soochow Univ, Dept Ophthalmol, Affiliated Hosp 1, Shizi St 188, Suzhou 21006, Jiangsu, Peoples R China
来源
CLINICAL OPHTHALMOLOGY | 2019年 / 13卷
关键词
astigmatism; posterior corneal astigmatism; aberrations; Q value; Sirius; Scheimpflug photography; UNCORRECTED VISUAL-ACUITY; WAVE-FRONT ABERRATIONS; ANTERIOR SEGMENT; SPHERICAL-ABERRATION; PSEUDOPHAKIC EYES; ORDER ABERRATIONS; PUPIL SIZE; SURFACE; REPEATABILITY; PREVALENCE;
D O I
10.2147/OPTH.S212946
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To study the distribution of posterior corneal astigmatism (PCA) and its influencing factors in Chinese patients before cataract surgery. Patients and methods: A retrospective study was conducted in the First Affiliated Hospital of Soochow University, Suzhou, China. In all, this study enrolled 121 eligible eyes of 121 cataract patients. The astigmatism, aberrations and Q value of anterior, posterior and total cornea and anterior segment parameters (ACD, CCT, WTW, ATA) were measured by the Sirius System, and AL was measured by Lenstar LS 900. Cataract was diagnosed using slit-lamp examination. Results: The mean age of patients was 67.44 +/- 10.66 years old. Mean PCA was 0.31 +/- 0.17 (range 0.05-1.09) D and 85.9% eyes had PCA values <0.5 D. With-the-rule (WTR) astigmatism predominated the anterior cornea astigmatism (ACA) (48.8%) and total corneal astigmatism (TCA) (61.2%), while against-the-rule (ATR) astigmatism predominated posterior (86.0%). Significant positive correlation was found between the astigmatic power vector (APV) of ACA and PCA (Pearson correlation=0.318, P<0.001); TCA and PCA (Pearson correlation=0.204, P=0.025); keratometric astigmatism and PCA (Pearson correlation=0.356, P< 0.001); this study also found a positive correlation between primary spherical aberration (Z4 degrees) of the total cornea and PCA (Pearson correlation=0.266, P=0.003); primary spherical aberration (Z4 degrees) of the corneal front surface and PCA (Pearson correlation=0.260, P=0.004); total corneal aberrations (Total cornea root mean square [RMS]) and PCA (Pearson correlation=0.327, P< 0.001); total corneal higher-orderaberrations (Total HOA RMS) (Pearson correlation=0.232, P=0.011); total corneal lower-order aberrations (Total LOA RMS) (Pearson correlation=0.250, P=0.006). A positive linear correlation between Q value of corneal front surface and PCA, either 6 mm pupil diameter (Pearson correlation=0.264, P=0.003) or 8 mm pupil diameter (Pearson correlation=0.184, P=0.043) was found in this study. Conclusion: Corneal aberration, Q value (front surface specifically) was essential that we need to take into consideration when we conduct PCA and intraocularlens measurement in clinics.
引用
收藏
页码:1341 / 1352
页数:12
相关论文
共 50 条
  • [41] Posterior Corneal Characteristics of Cataract Patients with High Myopia
    Jing, Qinghe
    Tang, Yating
    Qian, Dongjin
    Lu, Yi
    Jiang, Yongxiang
    PLOS ONE, 2016, 11 (09):
  • [42] Prevalence of corneal astigmatism before cataract surgery in Indian population
    Prasher, Pawan
    Sandhu, Jasdeep Singh
    INTERNATIONAL OPHTHALMOLOGY, 2017, 37 (03) : 683 - 689
  • [43] Prevalence of corneal astigmatism before cataract surgery in Indian population
    Pawan Prasher
    Jasdeep Singh Sandhu
    International Ophthalmology, 2017, 37 : 683 - 689
  • [44] Correlations of Corneal Spherical Aberration with Astigmatism and Axial Length in Cataract Patients
    Zhang, Min
    Qian, Dongjin
    Jing, Qinghe
    Chen, Jiahui
    Deng, Michael
    Jiang, Yongxiang
    JOURNAL OF OPHTHALMOLOGY, 2019, 2019
  • [45] Preoperative corneal astigmatism among adult patients with cataract in Northern Nigeria
    Isyaku, Mohammed
    Ali, Syed A.
    Hassan, Sadiq
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (11) : 1094 - 1095
  • [46] Development of a program for toric intraocular lens calculation considering posterior corneal astigmatism, incision-induced posterior corneal astigmatism, and effective lens position
    Eom, Youngsub
    Ryu, Dongok
    Kim, Dae Wook
    Yang, Seul Ki
    Song, Jong Suk
    Kim, Sug-Whan
    Kim, Hyo Myung
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (10) : 1977 - 1986
  • [47] Characterization of posterior corneal astigmatism in a population with keratoconus
    Marques, Raquel Esteves
    Guerra, Paulo Silva
    Quintas, Ana Miguel
    Rodrigues, Walter
    SEMINARS IN OPHTHALMOLOGY, 2020, 35 (7-8) : 352 - 357
  • [48] Analysis of corneal astigmatism and aberration in chinese congenital cataract and developmental cataract patients before cataract surgery
    Xiaoyan Han
    Qi Fan
    Zhixiang Hua
    Xiaodi Qiu
    Dongjin Qian
    Jin Yang
    BMC Ophthalmology, 21
  • [49] Analysis of Changes in Anterior, Posterior and Total Corneal Astigmatism after On-Axis Cataract Surgery
    Lee, Kee Il
    Park, Yu Li
    Kim, Hyun Seung
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (01): : 25 - 35
  • [50] Corneal astigmatism in leprosy and its importance for cataract surgery
    Nongrum, Benjamin
    Chacko, Shirley
    Mathew, Priya Thomas
    Paulson
    LEPROSY REVIEW, 2017, 88 (01) : 154 - 158