Systematic analysis of measurement variability in lung cancer with multidetector computed tomography

被引:7
作者
Jiang, Binghu [1 ]
Zhou, Dan [2 ]
Sun, Yujie [3 ]
Wang, Jichen [2 ]
机构
[1] Nanjing Med Univ, Sir Run Run Hosp, Dept Radiol, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Radiol BenQ Med Ctr, Nanjing, Jiangsu, Peoples R China
[3] Nanjing Med Univ, Jiangsu Key Lab Canc Biomarkers Prevent & Treatme, Collaborat Innovat Ctr Canc Personalized Med, Dept Cell Biol,Canc Ctr,Key Lab Human Funct Genom, Nanjing, Jiangsu, Peoples R China
关键词
Computed tomography; lung cancer; measurement variability; SEMIAUTOMATED VOLUME MEASUREMENTS; PULMONARY NODULES; RESPONSE EVALUATION; TUMOR RESPONSE; SOLID TUMORS; INTEROBSERVER; REPRODUCIBILITY; RELIABILITY; CRITERIA;
D O I
10.4103/1817-1737.203750
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: To systematically analyze the nature of measurement variability in lung cancer with multidetector computed tomography (CT) scans. METHODS: Multidetector CT scans of 67 lung cancer patients were analyzed. Unidimensional (Response Evaluation Criteria in Solid Tumor criteria), bidimensional (World Health Organization criteria), and volumetric measurements were performed independently by ten radiologists and were repeated after at least 5 months. Repeatability and reproducibility measurement variations were estimated by analyzing reliability, agreement, variation coefficient, and misclassification statistically. The relationship of measurement variability with various sources was also analyzed. RESULTS: Analyses of 69 lung tumors with an average size of 1.1-12.1 cm (mean 4.3 cm) indicated that volumetric technique had the minimum measurement variability compared to the unidimensional or bidimensional technique. Tumor characteristics (object effect) could be the primary factor to influence measurement variability while the effect of raters (subjective effect) was faint. Segmentation and size in tumor characteristics were associated with measurement variability, and some mathematical function was established between the volumetric variability and tumor size. CONCLUSION: Volumetric technique has the minimum variability in measuring lung cancer, and measurement variability is associated with tumor size by nonlinear mathematical function.
引用
收藏
页码:95 / 100
页数:6
相关论文
共 18 条
[11]  
2-6
[12]   Volumetric Tumor Growth in Advanced Non-Small Cell Lung Cancer Patients With EGFR Mutations During EGFR-Tyrosine Kinase Inhibitor Therapy Developing Criteria to Continue Therapy Beyond RECIST Progression [J].
Nishino, Mizuki ;
Dahlberg, Suzanne E. ;
Cardarella, Stephanie ;
Jackman, David M. ;
Rabin, Michael S. ;
Ramaiya, Nikhil H. ;
Hatabu, Hiroto ;
Jaenne, Pasi A. ;
Johnson, Bruce E. .
CANCER, 2013, 119 (21) :3761-3768
[13]   Variability of Lung Tumor Measurements on Repeat Computed Tomography Scans Taken Within 15 Minutes [J].
Oxnard, Geoffrey R. ;
Zhao, Binsheng ;
Sima, Camelia S. ;
Ginsberg, Michelle S. ;
James, Leonard P. ;
Lefkowitz, Robert A. ;
Guo, Pingzhen ;
Kris, Mark G. ;
Schwartz, Lawrence H. ;
Riely, Gregory J. .
JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (23) :3114-3119
[14]   CT tumor measurement for therapeutic response assessment: Comparison of unidimensional, bidimensional, and volumetric techniques - Initial observations [J].
Prasad, SR ;
Jhaveri, KS ;
Saini, S ;
Hahn, PF ;
Halpern, EF ;
Sumner, JE .
RADIOLOGY, 2002, 225 (02) :416-419
[15]   Pulmonary nodules: Preliminary experience with three-dimensional evaluation [J].
Revel, MP ;
Lefort, C ;
Bissery, A ;
Bienvenu, M ;
Aycard, L ;
Chatellier, G ;
Frija, G .
RADIOLOGY, 2004, 231 (02) :459-466
[16]  
Therasse P, 2000, J NATL CANCER I, V92, P205, DOI 10.1093/jnci/92.3.205
[17]   Effect of nodule characteristics on variability of semiautomated volume measurements in pulmonary nodules detected in a lung cancer screening program [J].
Wang, Ying ;
van Klaveren, Rob J. ;
van der Zaag-Loonen, Hester J. ;
de Bock, Geertruida H. ;
Gietema, Hester A. ;
Xu, Dong Ming ;
Leusveld, Anne L. M. ;
de Koning, Harry J. ;
Scholten, Ernst T. ;
Verschakelen, Johny ;
Prokop, Mathias ;
Oudkerk, Matthijs .
RADIOLOGY, 2008, 248 (02) :625-631
[18]   A Pilot Study of Volume Measurement as a Method of Tumor Response Evaluation to Aid Biomarker Development [J].
Zhao, Binsheng ;
Oxnard, Geoffrey R. ;
Moskowitz, Chaya S. ;
Kris, Mark G. ;
Pao, William ;
Guo, Pingzhen ;
Rusch, Valerie M. ;
Ladanyi, Marc ;
Rizvi, Naiyer A. ;
Schwartz, Lawrence H. .
CLINICAL CANCER RESEARCH, 2010, 16 (18) :4647-4653