Open-capsule intraocular lens to prevent posterior capsule opacification

被引:10
作者
Katsuki, Yoko [1 ,2 ]
Matsushima, Hiroyuki [1 ]
Mukai, Koichiro [1 ]
Watabiki, Satoshi [1 ]
Aose, Masamoto [1 ]
Terauchi, Wataru [1 ]
Nagamoto, Toshiyuki [3 ]
Senoo, Tadashi [1 ]
机构
[1] Dokkyo Med Univ, Dept Ophthalmol, 880 Kitakobayashi, Mibu, Tochigi 3210293, Japan
[2] HOYA Corp, Div Med, Tokyo, Japan
[3] Nagamoto Eye Clin, Tokyo, Japan
关键词
OPTIC EDGE DESIGN; ENDOCAPSULAR EQUATOR RING; EPITHELIAL-CELLS; BENDING RING; AQUEOUS-HUMOR; LONG-TERM; SILICONE; SHARP; INHIBITION; EFFICACY;
D O I
10.1016/j.jcrs.2018.12.022
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To develop a single-piece open-capsule intraocular lens (IOL) that can be inserted through a small incision and that prevents posterior capsule opacification (PCO) by expanding the capsule and circulating aqueous humor into the capsular bag. Setting: Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan. Design: Experimental study. Method: Using the same hydrophobic acrylic material as the NY-60 IOL, a prototype open-capsule IOL was constructed. The IOL has a single optic and 2 haptics, with a 2.8 mm high spacer and holes through which aqueous humor circulates into the capsular bag by separating the anterior capsule from the posterior capsule and expanding the capsule. The open-capsule IOL or NY-60 (as a control group) was inserted in rabbit eyes. Posterior capsule opacification development was evaluated by measuring the thickness of the cell layer at the center of the posterior capsule on histopathologic specimens and statistically comparing the thickness between the open-capsule IOL group and control group. Results: The open-capsule IOL could be inserted through a 3.2 mm corneal incision using a D cartridge. The mean thickness of the cell layer at the center of the posterior capsule was 4.78 mu m +/- 2.61 (SD) in the open-capsule IOL group and 101.14 +/- 25.19 mu m in the control group and was significantly smaller in the open-capsule IOL group. Conclusion: The prototype single-piece IOL could be implanted through a small incision and prevented PCO by expanding the lens capsule and circulating aqueous humor into the capsular bag. (C) 2019 Published by Elsevier Inc. on behalf of ASCRS and ESCRS
引用
收藏
页码:1007 / 1012
页数:6
相关论文
共 47 条
[1]   Long-term capsule clarity with a disk-shaped intraocular lens [J].
Aliancy, Joah ;
Werner, Liliana ;
Ludlow, Jason ;
Nguyen, Jason ;
Masino, Bryan ;
Ha, Larry ;
Mamalis, Nick .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (04) :504-509
[2]   Influence of intraocular lens implantation on anterior capsule contraction and posterior capsule opacification [J].
Aose, Masamoto ;
Matsushima, Hiroyuki ;
Mukai, Koichiro ;
Katsuki, Yoko ;
Gotoh, Norihito ;
Senoo, Tadashi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12) :2128-2133
[3]   Comparison of posterior capsule opacification at 360-degree square edge hydrophilic and sharp edge hydrophobic acrylic intraocular lens in diabetic patients [J].
Bai, Ling ;
Zhang, Jin ;
Chen, Ling ;
Ma, Ting ;
Liang, Hou-Cheng .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (04) :725-729
[4]   Long-term effect of optic edge design in an acrylic intraocular lens on posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Sacu, S ;
Kriechbaum, K ;
Koeppl, C ;
Wirtitsch, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :954-961
[5]   Effect of a silicone intraocular lens with a sharp posterior optic edge on posterior capsule opacification [J].
Buehl, W ;
Menapace, R ;
Sacu, S ;
Kriechbaum, K ;
Koeppl, C ;
Wirtitsch, M ;
Georgopoulos, M ;
Findl, O .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (08) :1661-1667
[6]   Effect of an acrylic intraocular lens with a sharp posterior optic edge on posterior capsule opacification [J].
Buehl, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Sacu, S ;
Kiss, B ;
Petternel, V ;
Georgopoulos, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07) :1105-1111
[7]  
Chen KH, 1999, INVEST OPHTH VIS SCI, V40, P2513
[8]   Anterior capsule contraction with foldable silicone intraocular lenses [J].
Dahlhauser, KE ;
Wroblewski, KT ;
Mader, TH .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (09) :1216-1219
[9]   Three-year clinical comparison of 3-piece AcrySof and SI-40 silicone intraocular lenses [J].
Daynes, T ;
Spencer, TS ;
Doan, K ;
Mamalis, N ;
Olson, RJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (07) :1124-1129
[10]   Effect of four different intraocular lenses on posterior capsule opacification [J].
Duman, Rahmi ;
Karel, Fatih ;
Ozyol, Pelin ;
Ates, Can .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) :118-121