Sensitivity of quantitative myocardial dynamic contrast-enhanced MRI to saturation pulse efficiency, noise and t1 measurement error: Comparison of nonlinearity correction methods

被引:13
作者
Broadbent, David A. [1 ,2 ,3 ]
Biglands, John D. [1 ,2 ,3 ]
Ripley, David P. [1 ,3 ]
Higgins, David M. [4 ]
Greenwood, John P. [1 ,3 ]
Plein, Sven [1 ,3 ]
Buckley, David L. [1 ,3 ]
机构
[1] Univ Leeds, Div Biomed Imaging, Leeds LS2 9JT, W Yorkshire, England
[2] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[3] Univ Leeds, Multidisciplinary Cardiovasc Res Ctr, Leeds LS2 9JT, W Yorkshire, England
[4] Philips Healthcare, Guildford, Surrey, England
基金
美国国家卫生研究院;
关键词
cardiovascular magnetic resonance; perfusion; myocardial blood flow; simulation; quantification; nonlinearity correction; ARTERIAL INPUT FUNCTION; MAGNETIC-RESONANCE; BLOOD-FLOW; PERFUSION; HEART; QUANTIFICATION; VOLUME; ACCURATE;
D O I
10.1002/mrm.25726
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo compare methods designed to minimize or correct signal nonlinearity in quantitative myocardial dynamic contrast-enhanced (DCE) MRI. MethodsDCE-MRI studies were simulated and data acquired in eight volunteers. Signal nonlinearity was corrected using either a dual-bolus approach or model-based correction using proton-density weighted imaging (conventional or dual-sequence acquisition) or T-1 data (native or bookend). Scanning of healthy and infarcted myocardium at 3 T was simulated, including noise, saturation imperfection and T-1 measurement error. Data were analyzed using model-based deconvolution with a one-compartment (mono-exponential) model. ResultsSubstantial variation between methods was demonstrated in volunteers. In simulations the dual-bolus method proved stable for realistic levels of saturation efficiency but demonstrated bias due to residual nonlinearity. Model-based methods performed ideally in the absence of confounding error sources and were generally robust to noise or saturation imperfection, except for native T-1 based correction which was highly sensitive to the latter. All methods demonstrated large variation in accuracy above an over-saturation level where baseline signal was nulled. For the dual-sequence approach this caused substantial bias at the saturation efficiencies observed in volunteers. ConclusionThe choice of nonlinearity correction method in myocardial DCE-MRI impacts on accuracy and precision of estimated parameters, particularly in the presence of nonideal saturation. Magn Reson Med 75:1290-1300, 2016. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1290 / 1300
页数:11
相关论文
共 43 条
  • [1] Evaluation of the effect of myocardial segmentation errors on myocardial blood flow estimates from DCE-MRI
    Biglands, J.
    Magee, D.
    Boyle, R.
    Larghat, A.
    Plein, S.
    Radjenovic, A.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08) : 2423 - 2443
  • [2] Myocardial Blood Flow at Rest and Stress Measured with Dynamic Contrast-Enhanced MRI: Comparison of a Distributed Parameter Model with a Fermi Function Model
    Broadbent, David A.
    Biglands, John D.
    Larghat, Abdulghani
    Sourbron, Steven P.
    Radjenovic, Aleksandra
    Greenwood, John P.
    Plein, Sven
    Buckley, David L.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1591 - 1597
  • [3] Theory-based signal calibration with single-point T1 measurements for first-pass quantitative perfusion MRI studies
    Cernicanu, Alexandru
    Axel, Leon
    [J]. ACADEMIC RADIOLOGY, 2006, 13 (06) : 686 - 693
  • [4] Cardiovascular magnetic resonance perfusion imaging at 3-Tesla for the detection of coronary artery disease - A comparison with 1.5-Tesla
    Cheng, Adrian S. H.
    Pegg, Tammy J.
    Karamitsos, Theodoros D.
    Searle, Nick
    Jerosch-Herold, Michael
    Choudhury, Robin P.
    Adrian, P. Banning
    Neubauer, Stefan
    Robson, Matthew D.
    Selvanayagam, Joseph B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (25) : 2440 - 2449
  • [5] Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging
    Christian, TF
    Rettmann, DW
    Aletras, AH
    Liao, SL
    Taylor, JL
    Balaban, RS
    Arai, AE
    [J]. RADIOLOGY, 2004, 232 (03) : 677 - 684
  • [6] Improvement in breast lesion characterization with dynamic contrast-enhanced MRI using pharmacokinetic modeling and bookend T1 measurements
    Cron, GO
    Kelcz, F
    Santyr, GE
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) : 1066 - 1070
  • [7] Cron GO, 1999, MAGNET RESON MED, V42, P746, DOI 10.1002/(SICI)1522-2594(199910)42:4<746::AID-MRM17>3.0.CO
  • [8] 2-U
  • [9] Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study
    Dabir, Darius
    Child, Nicholas
    Kalra, Ashwin
    Rogers, Toby
    Gebker, Rolf
    Jabbour, Andrew
    Plein, Sven
    Yu, Chung-Yao
    Otton, James
    Kidambi, Ananth
    McDiarmid, Adam
    Broadbent, David
    Higgins, David M.
    Schnackenburg, Bernhard
    Foote, Lucy
    Cummins, Ciara
    Nagel, Eike
    Puntmann, Valentina O.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
  • [10] Water diffusion and exchange as they influence contrast enhancement
    Donahue, KM
    Weisskoff, RM
    Burstein, D
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01): : 102 - 110