Sensitivity of quantitative myocardial dynamic contrast-enhanced MRI to saturation pulse efficiency, noise and t1 measurement error: Comparison of nonlinearity correction methods

被引:13
作者
Broadbent, David A. [1 ,2 ,3 ]
Biglands, John D. [1 ,2 ,3 ]
Ripley, David P. [1 ,3 ]
Higgins, David M. [4 ]
Greenwood, John P. [1 ,3 ]
Plein, Sven [1 ,3 ]
Buckley, David L. [1 ,3 ]
机构
[1] Univ Leeds, Div Biomed Imaging, Leeds LS2 9JT, W Yorkshire, England
[2] Leeds Teaching Hosp NHS Trust, Dept Med Phys & Engn, Leeds, W Yorkshire, England
[3] Univ Leeds, Multidisciplinary Cardiovasc Res Ctr, Leeds LS2 9JT, W Yorkshire, England
[4] Philips Healthcare, Guildford, Surrey, England
基金
美国国家卫生研究院;
关键词
cardiovascular magnetic resonance; perfusion; myocardial blood flow; simulation; quantification; nonlinearity correction; ARTERIAL INPUT FUNCTION; MAGNETIC-RESONANCE; BLOOD-FLOW; PERFUSION; HEART; QUANTIFICATION; VOLUME; ACCURATE;
D O I
10.1002/mrm.25726
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo compare methods designed to minimize or correct signal nonlinearity in quantitative myocardial dynamic contrast-enhanced (DCE) MRI. MethodsDCE-MRI studies were simulated and data acquired in eight volunteers. Signal nonlinearity was corrected using either a dual-bolus approach or model-based correction using proton-density weighted imaging (conventional or dual-sequence acquisition) or T-1 data (native or bookend). Scanning of healthy and infarcted myocardium at 3 T was simulated, including noise, saturation imperfection and T-1 measurement error. Data were analyzed using model-based deconvolution with a one-compartment (mono-exponential) model. ResultsSubstantial variation between methods was demonstrated in volunteers. In simulations the dual-bolus method proved stable for realistic levels of saturation efficiency but demonstrated bias due to residual nonlinearity. Model-based methods performed ideally in the absence of confounding error sources and were generally robust to noise or saturation imperfection, except for native T-1 based correction which was highly sensitive to the latter. All methods demonstrated large variation in accuracy above an over-saturation level where baseline signal was nulled. For the dual-sequence approach this caused substantial bias at the saturation efficiencies observed in volunteers. ConclusionThe choice of nonlinearity correction method in myocardial DCE-MRI impacts on accuracy and precision of estimated parameters, particularly in the presence of nonideal saturation. Magn Reson Med 75:1290-1300, 2016. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1290 / 1300
页数:11
相关论文
共 43 条
[1]   Evaluation of the effect of myocardial segmentation errors on myocardial blood flow estimates from DCE-MRI [J].
Biglands, J. ;
Magee, D. ;
Boyle, R. ;
Larghat, A. ;
Plein, S. ;
Radjenovic, A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08) :2423-2443
[2]   Myocardial Blood Flow at Rest and Stress Measured with Dynamic Contrast-Enhanced MRI: Comparison of a Distributed Parameter Model with a Fermi Function Model [J].
Broadbent, David A. ;
Biglands, John D. ;
Larghat, Abdulghani ;
Sourbron, Steven P. ;
Radjenovic, Aleksandra ;
Greenwood, John P. ;
Plein, Sven ;
Buckley, David L. .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) :1591-1597
[3]   Theory-based signal calibration with single-point T1 measurements for first-pass quantitative perfusion MRI studies [J].
Cernicanu, Alexandru ;
Axel, Leon .
ACADEMIC RADIOLOGY, 2006, 13 (06) :686-693
[4]   Cardiovascular magnetic resonance perfusion imaging at 3-Tesla for the detection of coronary artery disease - A comparison with 1.5-Tesla [J].
Cheng, Adrian S. H. ;
Pegg, Tammy J. ;
Karamitsos, Theodoros D. ;
Searle, Nick ;
Jerosch-Herold, Michael ;
Choudhury, Robin P. ;
Adrian, P. Banning ;
Neubauer, Stefan ;
Robson, Matthew D. ;
Selvanayagam, Joseph B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (25) :2440-2449
[5]   Absolute myocardial perfusion in canines measured by using dual-bolus first-pass MR imaging [J].
Christian, TF ;
Rettmann, DW ;
Aletras, AH ;
Liao, SL ;
Taylor, JL ;
Balaban, RS ;
Arai, AE .
RADIOLOGY, 2004, 232 (03) :677-684
[6]   Improvement in breast lesion characterization with dynamic contrast-enhanced MRI using pharmacokinetic modeling and bookend T1 measurements [J].
Cron, GO ;
Kelcz, F ;
Santyr, GE .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (05) :1066-1070
[7]  
Cron GO, 1999, MAGNET RESON MED, V42, P746, DOI 10.1002/(SICI)1522-2594(199910)42:4<746::AID-MRM17>3.0.CO
[8]  
2-U
[9]   Reference values for healthy human myocardium using a T1 mapping methodology: results from the International T1 Multicenter cardiovascular magnetic resonance study [J].
Dabir, Darius ;
Child, Nicholas ;
Kalra, Ashwin ;
Rogers, Toby ;
Gebker, Rolf ;
Jabbour, Andrew ;
Plein, Sven ;
Yu, Chung-Yao ;
Otton, James ;
Kidambi, Ananth ;
McDiarmid, Adam ;
Broadbent, David ;
Higgins, David M. ;
Schnackenburg, Bernhard ;
Foote, Lucy ;
Cummins, Ciara ;
Nagel, Eike ;
Puntmann, Valentina O. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2014, 16
[10]   Water diffusion and exchange as they influence contrast enhancement [J].
Donahue, KM ;
Weisskoff, RM ;
Burstein, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (01) :102-110