Intra-aneurysmal hemodynamics in a large middle cerebral artery aneurysm with wall atherosclerosis

被引:15
作者
Tateshima, Satoshi [1 ,2 ]
Tanishita, Kazuo [3 ]
Omura, Hiroyoshi [3 ]
Sayre, James [5 ]
Villablanca, J. Pablo [2 ,4 ]
Martin, Neil [2 ,6 ]
Vinuela, Fernando [2 ]
机构
[1] Univ Calif Los Angeles, Med Ctr, Dept Radiol Sci, Div Intervent Neuroradiol, Los Angeles, CA 90095 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[3] Keio Univ, Fac Sci & Technol, Dept Syst Design Engn, Yokohama, Kanagawa 2235522, Japan
[4] Univ Calif Los Angeles, Div Diagnost Neuroradiol, Med Ctr, Los Angeles, CA 90095 USA
[5] Univ Calif Los Angeles, Los Angeles Sch Publ Hlth, Dept Biostat, Los Angeles, CA 90095 USA
[6] Univ Calif Los Angeles, Med Ctr, Div Neurosurg, Los Angeles, CA 90095 USA
来源
SURGICAL NEUROLOGY | 2008年 / 70卷 / 05期
关键词
Hemodynamics; Atherosclerosis; Remodeling; Cerebral aneurysm; Wall shear stress;
D O I
10.1016/j.surneu.2008.03.035
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The remodeling of arterial extra-cellular matrix induced by hemodynamic stimuli is involved in the process of atherosclerosis in the carotid and cerebral arteries. Scarce information is available on the relationship between atherosclerotic changes in brain aneurysms itself and its intra-aneurysmal hemodynamics. Methods: Surgical exploration of a large MCA aneurysm depicted extensive atherosclerotic changes. in the aneurysm wall. Computational tomographic angiography of this aneurysm was used to create an in vitro aneurysm model. This model was used to perform intra-aneurysmal flow measurement using particle imaging velocimetry and LDV. Intra-aneurysmal hemodynamic pattern with wall shear stress distribution was compared between areas with and without atherosclerotic changes. Results: No high oscillation of wall shear stress was observed on the atherosclerotic plaque area. However, the magnitude of wall shear stress tended to be higher in the area without atherosclerotic changes than the area with those changes (P<.001). There was no atherosclerotic change at the aneurysm inflow zone, where relatively fast flow velocity and higher magnitude of wall shear stress was noted. Conclusions: This single case of atherosclerosis in an aneurysm shows some similarity in hemodynamic values observed in cases of carotid atherosclerotic plaques. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:454 / 462
页数:9
相关论文
共 24 条
  • [11] PULSATILE FLOW AND ATHEROSCLEROSIS IN THE HUMAN CAROTID BIFURCATION - POSITIVE CORRELATION BETWEEN PLAQUE LOCATION AND LOW AND OSCILLATING SHEAR-STRESS
    KU, DN
    GIDDENS, DP
    ZARINS, CK
    GLAGOV, S
    [J]. ARTERIOSCLEROSIS, 1985, 5 (03): : 293 - 302
  • [12] Shear-stress effect on mitochondrial membrane potential and albumin uptake in cultured endothelial cells
    Kudo, S
    Morigaki, R
    Saito, J
    Ikeda, M
    Oka, K
    Tanishita, K
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2000, 270 (02) : 616 - 621
  • [13] LDV measurements in lateral model aneurysms of various sizes
    Liou, TM
    Chang, WC
    Liao, CC
    [J]. EXPERIMENTS IN FLUIDS, 1997, 23 (04) : 317 - 324
  • [14] Mantha A, 2006, AM J NEURORADIOL, V27, P1113
  • [15] Mouse model of cerebral aneurysm - Experimental induction by renal hypertension and local hemodynamic changes
    Morimoto, M
    Miyamoto, S
    Mizoguchi, A
    Kume, N
    Kita, T
    Hashimoto, N
    [J]. STROKE, 2002, 33 (07) : 1911 - 1915
  • [16] Ischaemic complication following obliteration of unruptured cerebral aneurysms with atherosclerotic or calcified neck
    Ohno, K
    Arai, T
    Isotani, E
    Nariai, T
    Hirakawa, K
    [J]. ACTA NEUROCHIRURGICA, 1999, 141 (07) : 699 - 706
  • [17] Pannu H, 2006, J NEUROSURG, V105, P418, DOI 10.3171/jns.2006.105.3.418
  • [18] COMPARATIVE-STUDY OF TRANSCRANIAL COLOR DUPLEX SONOGRAPHY AND TRANSCRANIAL DOPPLER SONOGRAPHY IN ADULTS
    SCHONING, M
    BUCHHOLZ, R
    WALTER, J
    [J]. JOURNAL OF NEUROSURGERY, 1993, 78 (05) : 776 - 784
  • [19] Tateshima S, 2007, AM J NEURORADIOL, V28, P622
  • [20] Intraaneurysmal flow dynamics study featuring an acrylic aneurysm model manufactured using a computerized tomography angiogram as a mold
    Tateshima, S
    Murayama, Y
    Villablanca, JP
    Morino, T
    Takahashi, H
    Yamauchi, T
    Tanishita, K
    Viñuela, F
    [J]. JOURNAL OF NEUROSURGERY, 2001, 95 (06) : 1020 - 1027