Preparation and characterization of copper nanoparticles/zinc oxide composite modified electrode and its application to glucose sensing

被引:76
作者
Kumar, S. Ashok [1 ,2 ]
Cheng, Hui-Wen [1 ]
Chen, Shen-Ming [1 ]
Wang, Sea-Fue [2 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
[2] Natl Taipei Univ Technol, Dept Mat & Mineral Resources Engn, Taipei 106, Taiwan
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2010年 / 30卷 / 01期
关键词
Glucose sensor; Non-enzymatic sensors; Copper nanoparticles; Zinc oxide; Modified electrode; WALL CARBON NANOTUBES; GOLD NANOPARTICLES; ZINC-OXIDE; SOL-GEL; ELECTROCHEMICAL DETECTION; HYDROGEN-PEROXIDE; MULTILAYER FILMS; BIOSENSOR; SENSOR; FABRICATION;
D O I
10.1016/j.msec.2009.09.001
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
We report a new method for selective detection of D(+)-glucose using a copper nanoparticles (Cu-NPs) attached zinc oxide (ZnO) film coated electrode. The ZnO and Cu-NPs were electrochemically deposited onto indium tin oxide (ITO) coated glass electrode and glassy carbon electrode (GCE) by layer-by-layer. In result, Cu-NPs/ZnO composite film topography was characterized by scanning electron microscopy (SEM) and atomic force microscopy (AFM). respectively. SEM and AFM confirmed the presence of nanometer sized Cu-NPs/ZnO composite particles on the electrode surface. In addition, X-ray diffraction pattern revealed that Cu-NPs and ZnO films were attached onto the electrode surface. Indeed, the Cu-NPs/ZnO composite modified electrode showed excellent electrocatalytic activity for glucose oxidation in alkaline (0.1 M NaOH) solution. Further, we utilized the Cu-NPs/ZnO composite modified electrode as an electrochemical sensor for detection of glucose. This glucose sensor showed a linear relationship in the range from 1 x 10(-6) M to 1.53 x 10(-3) M and the detection limit (S/N = 3) was found to be 2 x 10(-7) M. The Cu-NPs/ZnO composite as a non-enzymatic glucose sensor presents a number of attractive features such as high sensitivity, stability, reproducibility, selectivity and fast response. The applicability of the proposed method to the determination of glucose in human urine samples was demonstrated with satisfactory results. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:86 / 91
页数:6
相关论文
共 41 条
[1]   The use of copper(II) oxide nanorod bundles for the non-enzymatic voltammetric sensing of carbohydrates and hydrogen peroxide [J].
Batchelor-McAuley, Christopher ;
Du, Yi ;
Wildgoose, Gregory G. ;
Compton, Richard G. .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) :230-235
[2]   Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane [J].
Chen, XH ;
Hu, YB ;
Wilson, GS .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1005-1013
[3]   Amperometric glucose biosensor based on boron-doped carbon nanotubes modified electrode [J].
Chen, Xiaoli ;
Chen, Jinhua ;
Deng, Chunyan ;
Xiao, Chunhui ;
Yang, Yanmin ;
Nie, Zhou ;
Yao, Shouzhuo .
TALANTA, 2008, 76 (04) :763-767
[4]   Enzyme immobilisation on electroactive nanostructured membranes (ENM): Optimised architectures for biosensing [J].
Crespilho, Frank N. ;
Ghica, M. Emilia ;
Gouveia-Caridade, Carla ;
Oliveira, Osvaldo N., Jr. ;
Brett, Christopher M. A. .
TALANTA, 2008, 76 (04) :922-928
[5]   A simple method to fabricate a chitosan-gold nanoparticles film and its application in glucose biosensor [J].
Du, Ying ;
Luo, Xi-Liang ;
Xu, Jing-Juan ;
Chen, Hong-Yuan .
BIOELECTROCHEMISTRY, 2007, 70 (02) :342-347
[6]   Amperometric detection of glucose using self-catalytic carbon paste electrodes [J].
Evans, RG ;
Banks, CE ;
Compton, RG .
ANALYST, 2004, 129 (05) :428-431
[7]   Oxidation and photo-induced oxidation of glucose at a polyaniline film modified by copper particles [J].
Farrell, ST ;
Breslin, CB .
ELECTROCHIMICA ACTA, 2004, 49 (25) :4497-4503
[8]   Electrochemical glucose sensor based on one-step construction of gold nanoparticle-chitosan composite film [J].
Feng, Duan ;
Wang, Fang ;
Chen, Zilin .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (02) :539-544
[9]   A new chemically amplified electrochemical system for the detection of biological affinity reactions: direct and competitive biotin assay [J].
Guo, LH ;
Yang, XQ .
ANALYST, 2005, 130 (07) :1027-1031
[10]  
Izaki M, 1996, APPL PHYS LETT, V68, P2439, DOI 10.1063/1.116160