Impact of communication delay on distributed load frequency control (dis-LFC) in multi-area power system (MAPS)

被引:0
作者
Imam, Auwal Mustapha [1 ,2 ,3 ]
Chaudhary, Kashif [1 ,3 ]
Kunya, Abdullahi Bala [4 ]
Rizvi, Zuhaib [1 ]
Ali, Jalil [1 ,3 ]
机构
[1] UTM, Ctr Laser, ISI SIR, Johor Baharu 81300, Malaysia
[2] Fed Univ Birnin Kebbi, Dept Phys Elect, Kebbi State 862104, Nigeria
[3] UTM, Fac Sci, Dept Phys, Johor Baharu 81300, Malaysia
[4] ABU, Dept Elect Engn, Zaria 1045, Nigeria
来源
MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES | 2019年 / 15卷 / 04期
关键词
Control Area (CA); communication delay; LFC; MPC; MAIPS; MODEL-PREDICTIVE CONTROL;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper, impact of communication delay on distributed load frequency control (dis-LFC) of multiarea interconnected power system (MAIPS) is investigated. Load frequency control (LFC), as one of ancillary services, is aimed at maintaining system frequency and inter-area tie-line power close to the scheduled values, by load reference set-point manipulation and consideration of the system constraints. Centralized LFC (cen-LFC) requires inherent communication bandwidth limitations, stability and computational complexity, as such, it is not a good technique for the control of large-scale and geographically wide power systems. To decrease the system dimensionality and increase performance efficiency, distributed and decentralized control techniques are adopted. In distributed LFC (dis-LFC) of MAIPS, each control area (CA) is equipped with a local controller and are made to exchange their control actions by communication with controllers in the neighboring areas. The delay in this communication can affect the performance of the LFC scheme and in a worst case deteriorates power system stability. To investigate the impact of this delay, model predictive controller (MPC) is employed in the presence of constraints and external disturbances to serve as LFC tracking control. The scheme discretizes the system and solves an on-line optimization at each time sample. The system is subjected to communication delay between the CAs, and the response to the step load perturbation with and without the delay. Time-based simulations were used on a three-area MAIPS in MATLAB/SIMULINK environment to verify the investigations. The overshoot and settling time in the results reveals deterioration of the control performance with delay. Also, the dis-LFC led to zero steady states errors for frequency deviations and enhanced the MAIPS' performance. With this achievement, MPC proved its constraints handling capability, online rolling optimization and ability to predict future behavior of systems.
引用
收藏
页码:626 / 632
页数:7
相关论文
共 50 条
[41]   Robust Cooperative Load Frequency Control for Enhancing Wind Energy Integration in Multi-Area Power Systems [J].
Hu, Zhijian ;
Zhang, Kun ;
Su, Rong ;
Wang, Ruiping .
IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2025, 22 :1508-1518
[42]   Robust Cooperative Load Frequency Control for Enhancing Wind Energy Integration in Multi-Area Power Systems [J].
Hu, Zhijian ;
Zhang, Kun ;
Su, Rong ;
Wang, Ruiping .
IEEE TRANSACTIONS ON AUTOMATION SCIENCE AND ENGINEERING, 2025, 22 :1508-1518
[43]   Hysteresis modulation-based sliding mode load frequency controller for multi-area power system [J].
Mahendran, Mahesh Veluchamy ;
Vijayan, Velappan .
INTERNATIONAL JOURNAL OF ADAPTIVE CONTROL AND SIGNAL PROCESSING, 2022, 36 (07) :1702-1723
[44]   Model-predictive control-based hybrid optimized load frequency control of multi-area power systems [J].
Mahendran, M., V ;
Vijayan, V. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (09) :1521-1537
[45]   A new method for optimization of Load Frequency Control parameters in multi-area power systems using Genetic Algorithms [J].
Rasolomampionona, Desire ;
Klos, Mariusz ;
Cirit, Can ;
Montegiglio, Pasquale ;
De Tuglie, Enrico Elio .
2022 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2022 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2022,
[46]   DMPC-based load frequency control of multi-area power systems with heterogeneous energy storage system considering SoC consensus [J].
Huang, Chongxin ;
Yang, Manting ;
Ge, Hui ;
Deng, Song ;
Chen, Chunyu .
ELECTRIC POWER SYSTEMS RESEARCH, 2024, 228
[47]   Anti-Windup Load Frequency Controller Design for Multi-Area Power System with Generation Rate Constraint [J].
Huang, Chongxin ;
Yue, Dong ;
Xie, Xiangpeng ;
Xie, Jun .
ENERGIES, 2016, 9 (05)
[48]   Adaptive LFC Incorporating Modified Virtual Rotor to Regulate Frequency and Tie-Line Power Flow in Multi-Area Microgrids [J].
Abubakr, Hussein ;
Guerrero, Josep M. ;
Vasquez, Juan C. ;
Mohamed, Tarek Hassan ;
Mahmoud, Karar ;
Darwish, Mohamed M. F. ;
Dahab, Yasser Ahmed .
IEEE ACCESS, 2022, 10 :33248-33268
[49]   Voltage Coordination in Multi-Area Power Systems via Distributed Model Predictive Control [J].
Moradzadeh, Mohammad ;
Boel, Rene ;
Vandevelde, Lieven .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (01) :513-521
[50]   Dandelion Optimizer-Based Combined Automatic Voltage Regulation and Load Frequency Control in a Multi-Area, Multi-Source Interconnected Power System with Nonlinearities [J].
Ali, Tayyab ;
Malik, Suheel Abdullah ;
Daraz, Amil ;
Aslam, Sheraz ;
Alkhalifah, Tamim .
ENERGIES, 2022, 15 (22)