Impact of communication delay on distributed load frequency control (dis-LFC) in multi-area power system (MAPS)

被引:0
作者
Imam, Auwal Mustapha [1 ,2 ,3 ]
Chaudhary, Kashif [1 ,3 ]
Kunya, Abdullahi Bala [4 ]
Rizvi, Zuhaib [1 ]
Ali, Jalil [1 ,3 ]
机构
[1] UTM, Ctr Laser, ISI SIR, Johor Baharu 81300, Malaysia
[2] Fed Univ Birnin Kebbi, Dept Phys Elect, Kebbi State 862104, Nigeria
[3] UTM, Fac Sci, Dept Phys, Johor Baharu 81300, Malaysia
[4] ABU, Dept Elect Engn, Zaria 1045, Nigeria
来源
MALAYSIAN JOURNAL OF FUNDAMENTAL AND APPLIED SCIENCES | 2019年 / 15卷 / 04期
关键词
Control Area (CA); communication delay; LFC; MPC; MAIPS; MODEL-PREDICTIVE CONTROL;
D O I
暂无
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper, impact of communication delay on distributed load frequency control (dis-LFC) of multiarea interconnected power system (MAIPS) is investigated. Load frequency control (LFC), as one of ancillary services, is aimed at maintaining system frequency and inter-area tie-line power close to the scheduled values, by load reference set-point manipulation and consideration of the system constraints. Centralized LFC (cen-LFC) requires inherent communication bandwidth limitations, stability and computational complexity, as such, it is not a good technique for the control of large-scale and geographically wide power systems. To decrease the system dimensionality and increase performance efficiency, distributed and decentralized control techniques are adopted. In distributed LFC (dis-LFC) of MAIPS, each control area (CA) is equipped with a local controller and are made to exchange their control actions by communication with controllers in the neighboring areas. The delay in this communication can affect the performance of the LFC scheme and in a worst case deteriorates power system stability. To investigate the impact of this delay, model predictive controller (MPC) is employed in the presence of constraints and external disturbances to serve as LFC tracking control. The scheme discretizes the system and solves an on-line optimization at each time sample. The system is subjected to communication delay between the CAs, and the response to the step load perturbation with and without the delay. Time-based simulations were used on a three-area MAIPS in MATLAB/SIMULINK environment to verify the investigations. The overshoot and settling time in the results reveals deterioration of the control performance with delay. Also, the dis-LFC led to zero steady states errors for frequency deviations and enhanced the MAIPS' performance. With this achievement, MPC proved its constraints handling capability, online rolling optimization and ability to predict future behavior of systems.
引用
收藏
页码:626 / 632
页数:7
相关论文
共 50 条
  • [31] Multi-area interconnected power system load frequency control using ELQR based state feedback gain controller
    Kumari, Naresh
    Malik, Nitin
    Jha, A. N.
    [J]. EVOLVING SYSTEMS, 2019, 10 (04) : 635 - 647
  • [32] A novel neuro-optimal approach for decentralized LFC design in multi-area power system
    Ansarian, M.
    Shakouri, H.
    Nazarzadeh, J.
    Sadeghzadeh, S. M.
    [J]. FIRST INTERNATIONAL POWER & ENERGY CONFERENCE (PECON 2006), PROCEEDINGS, 2006, : 167 - 172
  • [33] LFC and stabilization of multi-area interconnected power system by decentralized control of a SMES and Solid-State Phase Shifters
    Ngamroo, I
    Mitani, Y
    Tsuji, K
    [J]. PROCEEDINGS OF EMPD '98 - 1998 INTERNATIONAL CONFERENCE ON ENERGY MANAGEMENT AND POWER DELIVERY, VOLS 1 AND 2 AND SUPPLEMENT, 1998, : 85 - 90
  • [34] Load frequency predictive control for power systems concerning wind turbine and communication delay
    Tang, Xiaoming
    Wu, Yun
    Li, Yu
    Wen, Yiyu
    [J]. OPTIMAL CONTROL APPLICATIONS & METHODS, 2023, 44 (01) : 205 - 222
  • [35] Automatic Generation Control of Multi-area Power System with Network Constraints and Communication Delays
    Patel, Ragini
    Meegahapola, Lasantha
    Wang, Liuping
    Yu, Xinghuo
    McGrath, Brendan
    [J]. JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2020, 8 (03) : 454 - 463
  • [36] A new control scheme for PID load frequency controller of single-area and multi-area power systems
    Padhan, Dola Gobinda
    Majhi, Somanath
    [J]. ISA TRANSACTIONS, 2013, 52 (02) : 242 - 251
  • [37] Multi-Area Model Predictive Load Frequency Control: A Decentralized Approach
    Kumtepeli, Volkan
    Wang, Youyi
    Tripathi, Anshuman
    [J]. 2016 ASIAN CONFERENCE ON ENERGY, POWER AND TRANSPORTATION ELECTRIFICATION (ACEPT), 2016,
  • [38] Resilient fixed-order distributed dynamic output feedback load frequency control design for interconnected multi-area power systems
    Azarbahram, Ali
    Amini, Amir
    Sojoodi, Mandi
    [J]. IEEE-CAA JOURNAL OF AUTOMATICA SINICA, 2019, 6 (05) : 1139 - 1151
  • [39] H∞ Prediction Triggering Control of Multi-area Power Systems Load Frequency Control Under DoS Attacks
    Cheng, Zihao
    Yue, Dong
    Lan, Xinli
    Huang, Chongxin
    Hu, Songlin
    [J]. ADVANCED COMPUTATIONAL METHODS IN ENERGY, POWER, ELECTRIC VEHICLES, AND THEIR INTEGRATION, LSMS 2017, PT 3, 2017, 763 : 477 - 487
  • [40] Population extremal optimization-based extended distributed model predictive load frequency control of multi-area interconnected power systems
    Chen, Min-Rong
    Zeng, Guo-Qiang
    Xie, Xiao-Qing
    [J]. JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2018, 355 (17): : 8266 - 8295