Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker with a Single Scan

被引:5
|
作者
Liang, X.
Gong, S.
Zhou, Q.
Zhang, Z.
Xie, Y.
Niu, T.
机构
关键词
D O I
10.1118/1.4956119
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-F-J-211
引用
收藏
页码:3457 / 3457
页数:1
相关论文
共 50 条
  • [1] Scatter Correction for Clinical Cone-Beam CT System Using An Optimized Stationary Beam Blocker in a Single Scan
    Liang, X.
    Luo, C.
    Zhang, Z.
    Xie, Y.
    Niu, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E170 - E170
  • [2] Scatter correction for a clinical cone-beam CT system using an optimized stationary beam blocker in a single scan
    Liang, Xiaokun
    Jiang, Yangkang
    Zhao, Wei
    Zhang, Zhicheng
    Luo, Chen
    Xiong, Jing
    Yu, Shaode
    Yang, Xiaoming
    Sun, Jihong
    Zhou, Qinxuan
    Niu, Tianye
    Xie, Yaoqin
    MEDICAL PHYSICS, 2019, 46 (07) : 3165 - 3179
  • [3] Single-scan scatter correction for cone-beam CT using a stationary beam blocker: a preliminary study
    Niu, Tianye
    Zhu, Lei
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [4] Low-Dose and Scatter-Free Cone-Beam CT Imaging Using a Stationary Beam Blocker in a Single Scan: Phantom Studies
    Dong, Xue
    Petrongolo, Michael
    Niu, Tianye
    Zhu, Lei
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013
  • [5] Single Scan Scatter Correction in Cone Beam CT Using a Stationary Boundary Blocker and Compressed Sensing-based Scatter Estimation
    Meng, B.
    Lee, H.
    Xing, L.
    Fahimian, B. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S82 - S83
  • [6] Single-Scan Scatter Correction for Volumetric CT Using a Stationary Beam Blocker: Phantom Studies
    Niu, T.
    Zhu, L.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [7] Scatter measurement and correction method for cone-beam CT based on single grating scan
    Huang, Kuidong
    Shi, Wenlong
    Wang, Xinyu
    Dong, Yin
    Chang, Taoqi
    Zhang, Hua
    Zhang, Dinghua
    OPTICAL ENGINEERING, 2017, 56 (06)
  • [8] Development of a beam stop array system with dual scan mode for scatter correction of cone-beam CT
    So Hyun Ahn
    Jinho Choi
    Kyu Chan Lee
    Siyong Kim
    Rena Lee
    Journal of the Korean Physical Society, 2014, 64 : 1220 - 1229
  • [9] Development of a Beam Stop Array System with Dual Scan Mode for Scatter Correction of Cone-beam CT
    Ahn, So Hyun
    Choi, Jinho
    Lee, Kyu Chan
    Kim, Siyong
    Lee, Rena
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (08) : 1220 - 1229
  • [10] A Moving Blocker System for Cone-Beam Computed Tomography Scatter Correction
    Ouyang, L.
    Song, K.
    Solberg, T.
    Wang, J.
    MEDICAL PHYSICS, 2013, 40 (06)