摘要
Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.
引用
收藏
页码:5773 / 5776
页数:4
相关论文
共 15 条
[1]  
Alwan A, 2015, Global Status Report on Noncommunicable Diseases 2014
[2]  
[Anonymous], 2014, IEEE Std 1687-2014, DOI [DOI 10.1109/IEEESTD.2014.6804630, 10.1109/IEEESTD.2014.6755433, DOI 10.1109/IEEESTD.2014.6837414]
[3]   EFFECTS OF HYPERTENSION ON VISCOELASTICITY OF CAROTID AND FEMORAL ARTERIES IN HUMANS [J].
ARMENTANO, R ;
MEGNIEN, JL ;
SIMON, A ;
BELLENFANT, F ;
BARRA, J ;
LEVENSON, J .
HYPERTENSION, 1995, 26 (01) :48-54
[4]   Smooth muscle smart filtering helps to more efficiently protect the arterial wall [J].
Armentano, Ricardo L. ;
Barra, Juan Gabriel ;
Pessana, Franco Martin ;
Craiem, Damian O. ;
Graf, Sebastian ;
Santana, Daniel Bia ;
Sanchez, Ramiro A. .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2007, 26 (01) :62-70
[5]   Smooth muscle tone and arterial wall viscosity - An in vivo in vitro study [J].
Boutouyrie, P ;
Boumaza, S ;
Challande, P ;
Lacolley, P ;
Laurent, S .
HYPERTENSION, 1998, 32 (02) :360-364
[6]   Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration [J].
Chen, W ;
Kobayashi, T ;
Ichikawa, S ;
Takeuchi, Y ;
Togawa, T .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :569-574
[7]  
Ding X R, 2015, CONTINUOUS CUFFLESS
[8]   ARTERIAL TONOMETRY - REVIEW AND ANALYSIS [J].
DRZEWIECKI, GM ;
MELBIN, J ;
NOORDERGRAAF, A .
JOURNAL OF BIOMECHANICS, 1983, 16 (02) :141-152
[9]   MEASUREMENTS OF YOUNGS MODULUS OF ELASTICITY OF THE CANINE AORTA WITH ULTRASOUND [J].
HUGHES, DJ ;
BABBS, CF ;
GEDDES, LA ;
BOURLAND, JD .
ULTRASONIC IMAGING, 1979, 1 (04) :356-367
[10]  
Luo N, 2015, ADV FUNCTIONAL MAT