Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines

被引:0
|
作者
Lu, Hailiang [1 ]
Wen, Xishan [1 ]
Zhang, Chengwei [1 ]
Tong, Xuefang [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] SGCC, Wuhan High Voltage Res Inst, Lightning Protect Res Div, Wuhan, Peoples R China
关键词
flashover; HVDC; double circut line; backflash; lightning performance; ATP; OVERHEAD LINES; VOLTAGES;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Adopting +/-500kV HVDC double circuit transmission lines to transmit power can both economize line corridor and add unit corridor aera transmission capacity, so +/-500kV HVDC double circuit transmission lines are more and more adopted. Because the length of double circuit transmission lines is high, it is more likely to be attacked by lightning stroke, so lightning performance for double circuit transmission lines is studied in this paper. Applying ATP can calculate backflashvoer withstand levle when the datas like tower height, polarity configuration modes, soil resistivity and grounding resistance are changed. In the calculation, the insulators' behavior is judged by comparing the insulators' volt-time curves to the overvoltage, the system voltage and the induced voltage's influence on lightning withstanding level is considered.
引用
收藏
页码:3535 / +
页数:2
相关论文
共 50 条
  • [41] DEVELOPMENT OF A SYSTEM FOR MEASURING LIGHTNING VOLTAGE WAVE-FORMS ON INSULATOR STRINGS FOR 500KV OVERHEAD TRANSMISSION-LINES
    IWAMA, T
    SUMIYA, Y
    KIMATA, R
    KAWAMURA, T
    IEEE TRANSACTIONS ON POWER DELIVERY, 1990, 5 (04) : 1977 - 1982
  • [42] Evaluation of the backflashover performance of 150 kV and 400 kV double-circuit overhead transmission lines as affected by lightning attachment models and peak current distributions
    Datsios, Zacharias G.
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 235
  • [43] Research on Safety Protection for Live Working on ±500kV DC Transmission Line with AC and DC Multi-circuit Transmission Lines
    Xie, Yan
    Li, Mu
    Zheng, Changzheng
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN MATERIALS, MECHATRONICS AND CIVIL ENGINEERING (ICAMMCE 2017), 2017, 121 : 53 - 56
  • [44] Probabilistic Ampacity Rating of 500kV Overhead Transmission Lines in Zhejiang province
    Zhou, Xiangxian
    Wang, Shaohua
    Li, Te
    Cao, Junping
    Zou, Yang
    Xiang, Xinyu
    2018 3RD IEEE INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM), 2018, : 98 - 103
  • [45] Research on the Motion System of the Inspection Robot for 500kV Power Transmission Lines
    Fang, L. J.
    Wang, H. G.
    2010 1ST INTERNATIONAL CONFERENCE ON APPLIED ROBOTICS FOR THE POWER INDUSTRY, 2010,
  • [46] Analysis of lightning-induced current and voltages on 500 kV EHV double circuit transmission lines of type DL3° andd DT 20° in lightning protection system
    Jaipradidtham, C
    TENCON 2004 - 2004 IEEE REGION 10 CONFERENCE, VOLS A-D, PROCEEDINGS: ANALOG AND DIGITAL TECHNIQUES IN ELECTRICAL ENGINEERING, 2004, : C385 - C388
  • [47] LIGHTNING PERFORMANCE OF MULTI-CIRCUIT TRANSMISSION-LINES
    SARGENT, MA
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1972, PA91 (04): : 1730 - &
  • [48] Lightning performance of 500-kV double-circuit line schemes for the three-gorge project
    Huang, WG
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 736 - 743
  • [49] Studying of Lightning Surge Transient Effect on 500 kV Quadruple Circuit Transmission Line
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung S.
    Ayu, Rica S.
    2016 6TH INTERNATIONAL ANNUAL ENGINEERING SEMINAR (INAES), 2016, : 276 - 279
  • [50] 500kV Transmission Line Lightning Transformation Evaluation Based on Improved Analytic Hierarchy Process
    Duan, R. C.
    Wang, F. H.
    Liu, Y. D.
    Huang, R. H.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,