Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines

被引:0
|
作者
Lu, Hailiang [1 ]
Wen, Xishan [1 ]
Zhang, Chengwei [1 ]
Tong, Xuefang [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] SGCC, Wuhan High Voltage Res Inst, Lightning Protect Res Div, Wuhan, Peoples R China
关键词
flashover; HVDC; double circut line; backflash; lightning performance; ATP; OVERHEAD LINES; VOLTAGES;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Adopting +/-500kV HVDC double circuit transmission lines to transmit power can both economize line corridor and add unit corridor aera transmission capacity, so +/-500kV HVDC double circuit transmission lines are more and more adopted. Because the length of double circuit transmission lines is high, it is more likely to be attacked by lightning stroke, so lightning performance for double circuit transmission lines is studied in this paper. Applying ATP can calculate backflashvoer withstand levle when the datas like tower height, polarity configuration modes, soil resistivity and grounding resistance are changed. In the calculation, the insulators' behavior is judged by comparing the insulators' volt-time curves to the overvoltage, the system voltage and the induced voltage's influence on lightning withstanding level is considered.
引用
收藏
页码:3535 / +
页数:2
相关论文
共 50 条
  • [31] Lightning study and experience on the first 500kV Transmission Line Arrester in Malaysia
    Rawi, Iryani Mohamed
    Ab Kadir, M. Z. A.
    Azis, Norhafiz
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 1106 - 1109
  • [32] Observation of lightning at 500-kV transmission lines (Part 1)
    Ouchi, K
    Kikuchi, TK
    Ozawa, A
    Tamura, Y
    Nakada, M
    ELECTRICAL ENGINEERING IN JAPAN, 2000, 130 (02) : 59 - 67
  • [33] Analysis on lightning overvoltage of 500kV substation
    Shao Yu
    Shao Ming
    Shi Feng
    Wang Kun
    MECHATRONICS, ROBOTICS AND AUTOMATION, PTS 1-3, 2013, 373-375 : 1541 - 1545
  • [34] Phase Arrangement for 500kV Quadruple Circuit Transmission Line in Indonesia
    Kusuma, Aristo Adi
    Pramana, Putu Agus Aditya
    Munir, Buyung S.
    2016 INTERNATIONAL CONFERENCE ON SMART GREEN TECHNOLOGY IN ELECTRICAL AND INFORMATION SYSTEMS (ICSGTEIS), 2016, : 33 - 37
  • [35] Assessment of Lightning Shielding Performance of Double-Circuit UHV Overhead Transmission Lines
    He, Hengxin
    He, Junjia
    Xie, ShiJun
    Yao, Shuai
    Zhang, Dandan
    Dong, Manling
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [36] Numerical simulation of windage yaw of 500kV uhv transmission lines
    Liu, Xiao-Hui
    Yan, Bo
    Lin, Xue-Song
    Li, Wen-Yun
    Gongcheng Lixue/Engineering Mechanics, 2009, 26 (01): : 244 - 249
  • [37] Investigation on bird damage to composite insulators of 500kV transmission lines
    Investigation on bird damage to composite insulators of 500kV transmission lines
    Liang, X.-M., 2005, Power System Technology Press (29)
  • [38] Flashover pattern analysis for 275 kV double circuit transmission lines during direct lightning strikes
    Ahmed, Nasiru Yahaya
    Illias, Hazlee Azil
    Mokhlis, Hazlie
    Fahmi, Daniar
    Abdullah, Noradlina
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 228
  • [39] Research on electromagnetic environment of ±800 kV and ±500 kV double-circuit DC transmission lines on the same tower
    Wu, Gaobo
    Li, Jian
    Chen, Yuan
    Luo, Chujun
    Wang, Rusong
    Lin, Fang
    Dianwang Jishu/Power System Technology, 2015, 39 (09): : 2532 - 2538
  • [40] Probability parameter estimation of outage rate effects for lightning overvoltage analysis on 500 kV EHV double circuit transmission lines using neural networks
    Jaipradidtham, C.
    IPEC: 2005 INTERNATIONAL POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2005, : 803 - 808