Lightning Backflash Performance for ±500kV Double Circuit Transmission Lines

被引:0
|
作者
Lu, Hailiang [1 ]
Wen, Xishan [1 ]
Zhang, Chengwei [1 ]
Tong, Xuefang [2 ]
机构
[1] Wuhan Univ, Sch Elect Engn, Wuhan 430072, Peoples R China
[2] SGCC, Wuhan High Voltage Res Inst, Lightning Protect Res Div, Wuhan, Peoples R China
关键词
flashover; HVDC; double circut line; backflash; lightning performance; ATP; OVERHEAD LINES; VOLTAGES;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Adopting +/-500kV HVDC double circuit transmission lines to transmit power can both economize line corridor and add unit corridor aera transmission capacity, so +/-500kV HVDC double circuit transmission lines are more and more adopted. Because the length of double circuit transmission lines is high, it is more likely to be attacked by lightning stroke, so lightning performance for double circuit transmission lines is studied in this paper. Applying ATP can calculate backflashvoer withstand levle when the datas like tower height, polarity configuration modes, soil resistivity and grounding resistance are changed. In the calculation, the insulators' behavior is judged by comparing the insulators' volt-time curves to the overvoltage, the system voltage and the induced voltage's influence on lightning withstanding level is considered.
引用
收藏
页码:3535 / +
页数:2
相关论文
共 50 条
  • [21] LIGHTNING ARRESTERS DEVELOPED FOR 500 KV TRANSMISSION-LINES
    OHKI, Y
    YASUFUKU, S
    IEEE ELECTRICAL INSULATION MAGAZINE, 1994, 10 (04) : 61 - 62
  • [22] Lightning Performance of 275 kV Transmission Lines
    Bhattarai, R.
    Rashedin, R.
    Venkatesan, S.
    Haddad, A.
    Griffiths, H.
    Harid, N.
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 983 - 987
  • [23] Electric Field Distribution Calculation and Analysis of Composite Insulators Operating on Double Circuit Transposition Tower in 500kV Transmission Lines
    Guo, Chenjun
    Liu, Lishuai
    Yu, Hong
    Ma, Yi
    Mei, Hongwei
    Wang, Liming
    2019 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE 2019), 2019, : 486 - 489
  • [24] Design and Testing of 500kV Double Circuit Monopoles for the Heartland Transmission Project in Edmonton, Alberta
    Kumar, Kishor
    Dwyer, Jason
    ELECTRICAL TRANSMISSION AND SUBSTATION STRUCTURES 2015: TECHNICAL CHALLENGES AND INNOVATIVE SOLUTIONS IN GRID MODERNIZATION, 2015, : 337 - 350
  • [25] Lightning transient simulation of double circuit transmission lines
    Wang, Qingping
    Chen, Chaoying
    Gaodianya Jishu/High Voltage Engineering, 2001, 27 (06):
  • [26] Influence of AC transmission lines on parallelly erected ±500 kV HVDC double circuit transmission lines and suppression measure
    Li, Tao
    Li, Xin-Nian
    Jiang, Wei-Ping
    Gao, Jian
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (19): : 70 - 75
  • [27] Assessment of Lightning Backflash Outage Rate of Quadruple-circuit Transmission Lines due to Subsequent Strokes
    Huang, Bo
    Fu, Zhengcai
    Jiang, Anfeng
    Wang, Guoli
    Li, Ruihai
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 917 - 921
  • [28] The study of ground distance protection of 500kV quadruple-circuit transmission lines On the same tower
    Sun, Shujie
    Tai, Nengling
    Bo, Zhinqian
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 436 - +
  • [29] Research on lightning performance of insulated ground wire in 500kV extra high voltage transmission line
    Ma, Yutang
    Chen, Kui
    Ma, Yi
    Wang, Lei
    Cao, Xiaobin
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 768 - 771
  • [30] Observation of lightning at 500-kV transmission lines (Part 1)
    Ouchi, Katsuhiro, 1600, Scripta Technica Inc, New York, NY, United States (130):