A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators

被引:9
|
作者
Jirschik, Mario [1 ]
Keyl, Cornelius [1 ]
Beyersdorf, Friedhelm [1 ]
机构
[1] Univ Herzzentrum Freiburg Bad Krozingen, Dept Cardiovasc Surg, D-79189 Bad Krozingen, Germany
来源
PERFUSION-UK | 2009年 / 24卷 / 06期
关键词
extracorporeal circulation; oxygenator; microbubble; gaseous microemboli; cardiopulmonary bypass; CORONARY-BYPASS SURGERY; PERFUSIONIST INTERVENTIONS; CARDIOPULMONARY BYPASS; MICROEMBOLI;
D O I
10.1177/0267659109358206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Microbubbles generated during heart surgery on extracorporeal circulation have been implicated as a possible cause of postoperative neurocognitive dysfunction and negative outcome. The main sources of microbubbles in the extracorporeal circuit are air leaking from the venous cannulation site, air delivered by drug and volume administration, during the taking of blood samples, during hemofiltration, and by using vacuum-assisted venous drainage (VAVD). Membrane oxygenators, although not designed for the elimination of gaseous microbubbles, can eliminate much of this air. Aim of the study/hypothesis: The aim of this study was to test the hypothesis that the amount of microbubbles passing through the oxygenator varies depending on the oxygenator design. Methods: one hundred patients undergoing aortic valve replacement with cardiopulmonary bypass (CPB) were included in a retrospective clinical trial assessing the bubble elimination of the two oxygenators routinely used in our clinic. The oxygenators (Quadrox-iAdult/Polystan Safe Maxi) are manufactured with the same hollow-fiber material, but display different designs. Bubbles were detected by a two-channel ultrasound bubble counter. The probes were placed directly at the inlet and the outlet of the oxygenators. The filtration index was calculated by the bubble counter as a measure of the percentage reduction of bubble volume and number. Results: The Quadrox has a significantly higher filtration index (92.3% [ 89.7; 95.1], median [25(th), 75(th) percentile]) than the Polystan (74.9% [64.2; 80.9], p<0.001), indicating the superior ability of the Quadrox to eliminate microbubbles. Conclusion: Our study demonstrates major differences in the capacity of bubble elimination of the oxygenators being investigated, possibly depending on oxygenator design.
引用
收藏
页码:423 / 427
页数:5
相关论文
共 50 条
  • [41] A clinical comparison of glycol and water-based heater-cooler systems for cardiopulmonary bypass
    Ohlrich, Kelly
    Kwon, Jennie
    Hill, Morgan A.
    Ayala, Mckenzie
    Stone, Amber
    Bruner, Samantha
    Pollard, Melissa
    Dell'Aiera, Laura
    Fitzgerald, David
    Kilic, Arman
    PERFUSION-UK, 2024, : 947 - 954
  • [42] Comparison of Different Doses of ε-Aminocaproic Acid in Children for Tetralogy of Fallot Surgery: Clinical Efficacy and Safety
    Sarupria, Anju
    Makhija, Neeti
    Lakshmy, Ramakrishnan
    Kiran, Usha
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (01) : 23 - 29
  • [43] Pulsatile versus non-pulsatile perfusion in coronary artery bypass operation: The comparison of laboratory and clinical outcomes
    Shahandashti, Farshad Jalili
    Asadian, Sanaz
    Habibi, Neda
    Gorjipour, Farhad
    Jalali, Amirhossein
    Toloueitabar, Yaser
    PERFUSION-UK, 2023, 38 (05): : 1053 - 1061
  • [44] Cardiac surgery in the elderly:: Comparison of medium-term clinical outcomes in octogenarians and the elderly from 75 to 79 years
    Javier Lopez-Rodriguez, F.
    Gonzalez-Santos, Jose M.
    y Maria Bueno, M. Jose Dalmau
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (06): : 579 - 588
  • [45] The comparison of albumin and 6% hydroxyethyl starches (130/0.4) in cardiac surgery: a meta-analysis of randomized controlled clinical trials
    Wei, Ling
    Li, Dongping
    Sun, Lin
    BMC SURGERY, 2021, 21 (01)
  • [46] Comparison of 4% Albumin and Ringer's Acetate on Hemodynamics in On-pump Cardiac Surgery: An Exploratory Analysis of a Randomized Clinical Trial
    Vlasov, Hanna
    Wilkman, Erika
    Petaja, Liisa
    Suojaranta, Raili
    Hiippala, Seppo
    Tolonen, Hanna
    Jormalainen, Mikko
    Raivio, Peter
    Juvonen, Tatu
    Pesonen, Eero
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (10) : 2269 - 2277
  • [47] Capillary leak syndrome in children who undergo cardiopulmonary bypass:: clinical outcome in comparison with complement activation and C1 inhibitor
    Stiller, B
    Sonntag, J
    Dähnert, I
    Alexi-Meskishvili, V
    Hetzer, R
    Fischer, T
    Lange, PE
    INTENSIVE CARE MEDICINE, 2001, 27 (01) : 193 - 200
  • [48] Comparison of Renal Function in Coronary Artery Bypass Graft Surgery with Pulsatile versus Non-pulsatile Perfusion: A Randomized Clinical Trial
    Mali, Shahriar
    Montazerghaem, Hossein
    Salehi, Sahra
    Jambarsang, Sara
    Tajamolian, Ahmad
    INTERNATIONAL CARDIOVASCULAR RESEARCH JOURNAL, 2021, 15 (03) : 105 - 110
  • [49] A clinical comparison of the effects of six disposable cardiopulmonary bypass circuits on bleeding and coagulation: a quality assurance project; [Une comparaison clinique des effets de six circuits de circulation extracorporelle à usage unique sur les saignements et la coagulation : un projet d’assurance qualité]
    Sunpreet Takhar
    Selene Martinez-Perez
    Brian Beairsto
    Raphael Derman
    Cyril Serrick
    Margarita Otalora-Esteban
    Cielo Bingley
    Stuart A. McCluskey
    Keyvan Karkouti
    Justyna Bartoszko
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2025, 72 (2): : 319 - 333
  • [50] Analysis of clinical outcome and postoperative organ function effects in a propensity-matched comparison between conventional and minimally invasive mitral valve surgery
    Missault, Sophie
    Van Causenbroeck, Jerome
    Vandewiele, Korneel
    Czapla, Jens
    Philipsen, Tine
    Francois, Katrien
    Bove, Thierry
    JOURNAL OF CARDIAC SURGERY, 2020, 35 (12) : 3276 - 3285