A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators

被引:9
|
作者
Jirschik, Mario [1 ]
Keyl, Cornelius [1 ]
Beyersdorf, Friedhelm [1 ]
机构
[1] Univ Herzzentrum Freiburg Bad Krozingen, Dept Cardiovasc Surg, D-79189 Bad Krozingen, Germany
来源
PERFUSION-UK | 2009年 / 24卷 / 06期
关键词
extracorporeal circulation; oxygenator; microbubble; gaseous microemboli; cardiopulmonary bypass; CORONARY-BYPASS SURGERY; PERFUSIONIST INTERVENTIONS; CARDIOPULMONARY BYPASS; MICROEMBOLI;
D O I
10.1177/0267659109358206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Microbubbles generated during heart surgery on extracorporeal circulation have been implicated as a possible cause of postoperative neurocognitive dysfunction and negative outcome. The main sources of microbubbles in the extracorporeal circuit are air leaking from the venous cannulation site, air delivered by drug and volume administration, during the taking of blood samples, during hemofiltration, and by using vacuum-assisted venous drainage (VAVD). Membrane oxygenators, although not designed for the elimination of gaseous microbubbles, can eliminate much of this air. Aim of the study/hypothesis: The aim of this study was to test the hypothesis that the amount of microbubbles passing through the oxygenator varies depending on the oxygenator design. Methods: one hundred patients undergoing aortic valve replacement with cardiopulmonary bypass (CPB) were included in a retrospective clinical trial assessing the bubble elimination of the two oxygenators routinely used in our clinic. The oxygenators (Quadrox-iAdult/Polystan Safe Maxi) are manufactured with the same hollow-fiber material, but display different designs. Bubbles were detected by a two-channel ultrasound bubble counter. The probes were placed directly at the inlet and the outlet of the oxygenators. The filtration index was calculated by the bubble counter as a measure of the percentage reduction of bubble volume and number. Results: The Quadrox has a significantly higher filtration index (92.3% [ 89.7; 95.1], median [25(th), 75(th) percentile]) than the Polystan (74.9% [64.2; 80.9], p<0.001), indicating the superior ability of the Quadrox to eliminate microbubbles. Conclusion: Our study demonstrates major differences in the capacity of bubble elimination of the oxygenators being investigated, possibly depending on oxygenator design.
引用
收藏
页码:423 / 427
页数:5
相关论文
共 50 条
  • [31] A clinical comparison of the effects of six disposable cardiopulmonary bypass circuits on bleeding and coagulation: a quality assurance project
    Takhar, Sunpreet
    Martinez-Perez, Selene
    Beairsto, Brian
    Derman, Raphael
    Serrick, Cyril
    Otalora-Esteban, Margarita
    Bingley, Cielo
    Mccluskey, Stuart A.
    Karkouti, Keyvan
    Bartoszko, Justyna
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2025, 72 (02): : 319 - 333
  • [32] Pulsatile and nonpulsatile extracorporeal circulation using Capiox(R)E Terumo oxygenator: A comparison study with Ultrox(R) and Maxima(R) membrane oxygenators
    Minami, K
    Bairaktaris, A
    Murray, E
    Weitkemper, H
    Dramburg, W
    Korfer, R
    JOURNAL OF CARDIOVASCULAR SURGERY, 1997, 38 (03) : 227 - 232
  • [33] A survey on air bubble detector placement in the CPB circuit: a 2011 cross-sectional analysis of the practice of Certified Clinical Perfusionists
    Kelting, T.
    Searles, B.
    Darling, E.
    PERFUSION-UK, 2012, 27 (04): : 345 - 351
  • [34] Comparison of the effectiveness and safety of a new de-airing technique with a standardized carbon dioxide insufflation technique in open left heart surgery: A randomized clinical trial
    Al-Rashidi, Faleh
    Landenhed, Maya
    Blomquist, Sten
    Hoeglund, Peter
    Karlsson, Per-Axel
    Pierre, Leif
    Koul, Bansi
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 141 (05) : 1128 - 1133
  • [35] Ozone micro-bubble aeration using the ceramic ultrafiltration membrane with superior oxidation performance for 2, 4-D elimination
    Han, Wei-Ran
    Wang, Wen-Long
    Qiao, Tie-Jun
    Wang, Wei
    Su, Hang
    Xu, Chen-Xin
    Wu, Qian-Yuan
    WATER RESEARCH, 2023, 237
  • [36] Comparison of Clinical Scoring Tools to Predict Heparin-Induced Thrombocytopenia in Cardiac Surgery
    Allan, Kari A.
    Crow, Jessica R.
    Chasler, Jessica E.
    Athale, Janhavi
    Lindsley, John P.
    Shermock, Kenneth M.
    Streiff, Michael
    Whitman, Glenn J. R.
    Dane, Kathryn E.
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2022, 34 (02) : 570 - 580
  • [37] Innovative experimental animal models for real-time comparison of antithrombogenicity between two oxygenators using dual extracorporeal circulation circuits and indocyanine green fluorescence imaging
    Sakurai, Hironobu
    Fujiwara, Tatsuki
    Ohuchi, Katsuhiro
    Hijikata, Wataru
    Inoue, Yusuke
    Maruyama, Osamu
    Tahara, Tomoki
    Yokota, Sachie
    Tanaka, Yui
    Takewa, Yoshiaki
    Mizuno, Tomohiro
    Arai, Hirokuni
    ARTIFICIAL ORGANS, 2023, 47 (01) : 77 - 87
  • [38] Comparison of continuous infusion and intermittent bolus administration of Cisatracurium in cardiac surgery: a randomized clinical trial
    Mirinejad, Moosa
    Yaghoubi, Ali Reza
    Azarfarin, Rasoul
    Asl, Azin Alizadeh
    RAWAL MEDICAL JOURNAL, 2007, 32 (01):
  • [39] MEMBRANE VERSUS BUBBLE OXYGENATOR IN HYPERTHERMIC REGIONAL PERFUSION - A PROSPECTIVE RANDOMIZED CLINICAL-STUDY
    HUBER, R
    MENNICKE, C
    HEITMANN, KU
    HELLING, HJ
    HUBER, PM
    EUROPEAN SURGICAL RESEARCH, 1994, 26 (04) : 210 - 220
  • [40] Comparison of Epsilon Aminocaproic Acid and Tranexamic Acid in Thoracic Aortic Surgery: Clinical Efficacy and Safety
    Makhija, Neeti
    Sarupria, Anju
    Choudhary, Shiv Kumar
    Das, Sambhunath
    Lakshmy, Ramakrishnan
    Kiran, Usha
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2013, 27 (06) : 1201 - 1207