A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators

被引:9
|
作者
Jirschik, Mario [1 ]
Keyl, Cornelius [1 ]
Beyersdorf, Friedhelm [1 ]
机构
[1] Univ Herzzentrum Freiburg Bad Krozingen, Dept Cardiovasc Surg, D-79189 Bad Krozingen, Germany
来源
PERFUSION-UK | 2009年 / 24卷 / 06期
关键词
extracorporeal circulation; oxygenator; microbubble; gaseous microemboli; cardiopulmonary bypass; CORONARY-BYPASS SURGERY; PERFUSIONIST INTERVENTIONS; CARDIOPULMONARY BYPASS; MICROEMBOLI;
D O I
10.1177/0267659109358206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Microbubbles generated during heart surgery on extracorporeal circulation have been implicated as a possible cause of postoperative neurocognitive dysfunction and negative outcome. The main sources of microbubbles in the extracorporeal circuit are air leaking from the venous cannulation site, air delivered by drug and volume administration, during the taking of blood samples, during hemofiltration, and by using vacuum-assisted venous drainage (VAVD). Membrane oxygenators, although not designed for the elimination of gaseous microbubbles, can eliminate much of this air. Aim of the study/hypothesis: The aim of this study was to test the hypothesis that the amount of microbubbles passing through the oxygenator varies depending on the oxygenator design. Methods: one hundred patients undergoing aortic valve replacement with cardiopulmonary bypass (CPB) were included in a retrospective clinical trial assessing the bubble elimination of the two oxygenators routinely used in our clinic. The oxygenators (Quadrox-iAdult/Polystan Safe Maxi) are manufactured with the same hollow-fiber material, but display different designs. Bubbles were detected by a two-channel ultrasound bubble counter. The probes were placed directly at the inlet and the outlet of the oxygenators. The filtration index was calculated by the bubble counter as a measure of the percentage reduction of bubble volume and number. Results: The Quadrox has a significantly higher filtration index (92.3% [ 89.7; 95.1], median [25(th), 75(th) percentile]) than the Polystan (74.9% [64.2; 80.9], p<0.001), indicating the superior ability of the Quadrox to eliminate microbubbles. Conclusion: Our study demonstrates major differences in the capacity of bubble elimination of the oxygenators being investigated, possibly depending on oxygenator design.
引用
收藏
页码:423 / 427
页数:5
相关论文
共 50 条
  • [21] Elimination of sevoflurane is reduced in plasma-tight compared to conventional membrane oxygenators
    Prasser, C.
    Zelenka, M.
    Gruber, M.
    Philipp, A.
    Keyser, A.
    Wiesenack, C.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (02) : 152 - 157
  • [22] Clinical evaluation of five commercially available adult oxygenators in terms of pressure drop during normothermic and hypothermic cardiopulmonary bypass
    Ji, Bingyang
    Wang, Hongyue
    Miao, Na
    Xing, Jialin
    Liu, Wei
    Liu, Ruifang
    Long, Cun
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (05) : 310 - 316
  • [23] Clinical Evaluation of New Generation Oxygenators With Integrated Arterial Line Filters for Cardiopulmonary Bypass
    Onorati, Francesco
    Santini, Francesco
    Raffin, Federica
    Menon, Tiziano
    Graziani, Maria S.
    Chiominto, Bartolomeo
    Milano, Aldo
    Faggian, Giuseppe
    Mazzucco, Alessandro
    ARTIFICIAL ORGANS, 2012, 36 (10) : 875 - 885
  • [24] Pressure drop, shear stress, and activation of leukocytes during cardiopulmonary bypass: A comparison between hollow fiber and flat sheet membrane oxygenators
    Gu, YJ
    Boonstra, PW
    Graaff, R
    Rijnsburger, AA
    Mungroop, H
    van Oeveren, W
    ARTIFICIAL ORGANS, 2000, 24 (01) : 43 - 48
  • [25] Evaluation of the effects of three designs of oxygenators with integrated filters on clinical and haematological outcomes at an Australasian cardiothoracic unit
    Prakash, Minesh
    Sharma, Varun
    Oh, Timothy
    Lo, Casey
    Parkinson, Grant
    McCormack, David
    Conaglen, Paul
    Lin, Zaw
    Kejriwal, Nand
    Meikle, Felicity
    Peplow, Emma
    Bhana, Jack
    El Gamel, Adam
    PERFUSION-UK, 2023, 38 (05): : 983 - 992
  • [26] Comparison Between D901 Lilliput 1 and Kids D100 Neonatal Oxygenators: Toward Bypass Circuit Miniaturization
    De Rita, Fabrizio
    Marchi, Diego
    Lucchese, Gianluca
    Barozzi, Luca
    Dissegna, Roberta
    Menon, Tiziano
    Faggian, Giuseppe
    Mazzucco, Alessandro
    Luciani, Giovanni Battista
    ARTIFICIAL ORGANS, 2013, 37 (01) : E24 - E28
  • [27] Comparison of the effect of membrane sizes and fibre arrangements of two membrane oxygenators on the inflammatory response, oxygenation and decarboxylation in a rat model of extracorporeal membrane oxygenation
    Edinger, Fabian
    Schneck, Emmanuel
    Schulte, Charlotte
    Gehron, Johannes
    Mueller, Sabrina
    Sander, Michael
    Koch, Christian
    BMC CARDIOVASCULAR DISORDERS, 2020, 20 (01)
  • [28] Performance comparison of swirl-venturi bubble generator and conventional venturi bubble generator
    Wang, Xinyan
    Shuai, Yun
    Zhou, Xiaorui
    Huang, Zhengliang
    Yang, Yao
    Sun, Jingyuan
    Zhang, Haomiao
    Wang, Jingdai
    Yang, Yongrong
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2020, 154
  • [29] Comparison of the clinical application of reactive oxygen species and inflammatory markers in patients with endocarditis
    Ostrowski, Stanislaw
    Marcinkiewicz, Anna
    Nowak, Dariusz
    Zwolinski, Radoslaw
    Jaszewski, Ryszard
    ARCHIVES OF MEDICAL SCIENCE, 2012, 8 (02) : 244 - 249
  • [30] Comparison of extracapillary and endocapillary blood flow oxygenators for open heart surgery in dogs: Efficiency of gas exchange and platelet conservation
    Hoshi, K
    Tanaka, R
    Shibazaki, A
    Nagashima, Y
    Hirao, H
    Namiki, R
    Takashima, K
    Noishiki, Y
    Yamane, Y
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2003, 65 (03) : 357 - 361