A clinical comparison of bubble elimination in Quadrox and Polystan oxygenators

被引:9
|
作者
Jirschik, Mario [1 ]
Keyl, Cornelius [1 ]
Beyersdorf, Friedhelm [1 ]
机构
[1] Univ Herzzentrum Freiburg Bad Krozingen, Dept Cardiovasc Surg, D-79189 Bad Krozingen, Germany
来源
PERFUSION-UK | 2009年 / 24卷 / 06期
关键词
extracorporeal circulation; oxygenator; microbubble; gaseous microemboli; cardiopulmonary bypass; CORONARY-BYPASS SURGERY; PERFUSIONIST INTERVENTIONS; CARDIOPULMONARY BYPASS; MICROEMBOLI;
D O I
10.1177/0267659109358206
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Microbubbles generated during heart surgery on extracorporeal circulation have been implicated as a possible cause of postoperative neurocognitive dysfunction and negative outcome. The main sources of microbubbles in the extracorporeal circuit are air leaking from the venous cannulation site, air delivered by drug and volume administration, during the taking of blood samples, during hemofiltration, and by using vacuum-assisted venous drainage (VAVD). Membrane oxygenators, although not designed for the elimination of gaseous microbubbles, can eliminate much of this air. Aim of the study/hypothesis: The aim of this study was to test the hypothesis that the amount of microbubbles passing through the oxygenator varies depending on the oxygenator design. Methods: one hundred patients undergoing aortic valve replacement with cardiopulmonary bypass (CPB) were included in a retrospective clinical trial assessing the bubble elimination of the two oxygenators routinely used in our clinic. The oxygenators (Quadrox-iAdult/Polystan Safe Maxi) are manufactured with the same hollow-fiber material, but display different designs. Bubbles were detected by a two-channel ultrasound bubble counter. The probes were placed directly at the inlet and the outlet of the oxygenators. The filtration index was calculated by the bubble counter as a measure of the percentage reduction of bubble volume and number. Results: The Quadrox has a significantly higher filtration index (92.3% [ 89.7; 95.1], median [25(th), 75(th) percentile]) than the Polystan (74.9% [64.2; 80.9], p<0.001), indicating the superior ability of the Quadrox to eliminate microbubbles. Conclusion: Our study demonstrates major differences in the capacity of bubble elimination of the oxygenators being investigated, possibly depending on oxygenator design.
引用
收藏
页码:423 / 427
页数:5
相关论文
共 50 条
  • [11] Comparison of complement consumption and platelet accumulation between membrane oxygenators coated with a polymer or heparin
    Tagaya, Masashi
    Murataka, Takuo
    Okano, Shinya
    Handa, Hiroki
    Takahashi, Shunsuke
    PERFUSION-UK, 2024, 39 (06): : 1143 - 1151
  • [12] A clinical evaluation of the Maquet Quadrox-i Neonatal oxygenator with integrated arterial filter
    Ginther, R. M., Jr.
    Gorney, R.
    Cruz, R.
    PERFUSION-UK, 2013, 28 (03): : 194 - 199
  • [13] Evaluation of Quadrox-i and Capiox FX neonatal oxygenators with integrated arterial filters in eliminating gaseous microemboli and retaining hemodynamic properties during simulated cardiopulmonary bypass
    Lin, J.
    Dogal, N. M.
    Mathis, R. K.
    Qiu, F.
    Kunselman, A.
    Uendar, A.
    PERFUSION-UK, 2012, 27 (03): : 235 - 243
  • [14] Clinical evaluation of the air-handling properties of contemporary oxygenators with integrated arterial filter
    Stehouwer, Marco C.
    Legg, Kristina R.
    de Vroege, Roel
    Kelder, Johannes C.
    Hofman, Erik
    de Mol, Bastian A.
    Bruins, Peter
    PERFUSION-UK, 2017, 32 (02): : 118 - 125
  • [15] A Comparison of the Arterial Blood Concentration of Isoflurane During Cardiopulmonary Bypass Between 2 Polypropylene Oxygenators
    Alston, R. Peter
    Kitchen, Cathy
    McKenzie, Christopher
    Homer, Natalie
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2020, 34 (05) : 1184 - 1190
  • [16] Pulsatile flow decreases gaseous micro-bubble filtering properties of oxygenators without integrated arterial filters during cardiopulmonary bypass
    Milano, Aldo D.
    Dodonov, Mikhail
    Onorati, Francesco
    Menon, Tiziano
    Gottin, Leonardo
    Malerba, Giovanni
    Mazzucco, Alessandro
    Faggian, Giuseppe
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2013, 17 (05) : 811 - 817
  • [17] A retrospective comparison of blood transfusion requirements during cardiopulmonary bypass with two different small adult oxygenators
    Lahanas, A.
    Argerakis, P. W.
    Johnson, K. A.
    Burdan, M. L.
    Ozdirik, J. E.
    PERFUSION-UK, 2013, 28 (06): : 541 - 545
  • [18] Clinical evaluation of emboli removal by integrated versus non-integrated arterial filters in new generation oxygenators
    Jabur, Ghazwan N. S.
    Sidhu, Karishma
    Willcox, Timothy W.
    Mitchell, Simon J.
    PERFUSION-UK, 2016, 31 (05): : 409 - 417
  • [19] A clinical study for the durability of oxygenators on cardiopulmonary support
    Usui, A
    Murakami, F
    Ooshima, H
    Tomita, Y
    Yoshida, K
    Hibi, M
    Kawamura, M
    Muras, M
    ARTIFICIAL ORGANS, 1997, 21 (07) : 772 - 778
  • [20] In Vitro Comparison of Pediatric Oxygenators With and Without Integrated Arterial Filters in Maintaining Optimal Hemodynamic Stability and Managing Gaseous Microemboli
    Moroi, Morgan
    Force, Madison
    Wang, Shigang
    Kunselman, Allen R.
    Undar, Akif
    ARTIFICIAL ORGANS, 2018, 42 (04) : 420 - 431