Imperfection study on lateral thermal buckling of subsea pipeline triggered by a distributed buoyancy section

被引:10
作者
Wang, Zhenkui [1 ,2 ]
Tang, Yougang [1 ]
Soares, C. Guedes [3 ]
机构
[1] Tianjin Univ, Sch Civil Engn, State Key Lab Hydraul Engn Simulat & Safety, Tianjin 300350, Peoples R China
[2] UCL, Dept Civil Environm & Geomat Engn, London WC1E 6BT, England
[3] Univ Lisbon, Inst Super Tecn, Ctr Marine Technol & Ocean Engn CENTEC, Lisbon, Portugal
基金
中国国家自然科学基金;
关键词
Subsea pipelines; Initial imperfection; Lateral buckling; Distributed buoyancy section;
D O I
10.1016/j.marstruc.2020.102916
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Controlled lateral buckling is triggered by distributed buoyancy section at predesigned sites to release the axial force induced by high temperature and high pressure in subsea pipelines. Due to the larger diameter and smaller submerged weight of distributed buoyancy section, compared to the normal pipe section, imperfections are more easily introduced at the location of distributed buoyancy section. In this study, an analytical model is proposed to simulate lateral buckling triggered by a distributed buoyancy section for an imperfect subsea pipeline, which is validated by test data. Semi-analytical solutions are derived. First, snap-through buckling behaviour is discussed. Then the influence of initial imperfections on buckled configurations, post-buckling behaviour, displacement amplitude and maximum stress is discussed in detail. The results show that there is no snap-through phenomenon for large amplitude of initial imperfections, which appears only when the amplitude of imperfection is small enough. The displacement amplitude increases with the amplitude of initial imperfections, and it first increases and then decreases with wavelength of initial imperfection. Compared to a perfect pipeline, the maximum stress amplifies for relative small wavelength of initial imperfections. Therefore, a large enough wavelength of initial imperfection should be introduced.
引用
收藏
页数:17
相关论文
共 32 条
  • [1] [Anonymous], 2018, DNVGL-RP-F110
  • [2] Antunes BR, 2010, INT C OC OFFSH ARCT
  • [3] A simplified model of upheaval thermal buckling of subsea pipelines
    Croll, JGA
    [J]. THIN-WALLED STRUCTURES, 1997, 29 (1-4) : 59 - 78
  • [4] DE Oliveira Cardoso C., 2015, 25 INT OC POL ENG C, P15
  • [5] IN-SERVICE BUCKLING OF HEATED PIPELINES
    HOBBS, RE
    [J]. JOURNAL OF TRANSPORTATION ENGINEERING-ASCE, 1984, 110 (02): : 175 - 189
  • [6] Study on lateral buckling characteristics of a submarine pipeline with a single arch symmetric initial imperfection
    Hong, Zhaohui
    Liu, Run
    Liu, Wenbin
    Yan, Shuwang
    [J]. OCEAN ENGINEERING, 2015, 108 : 21 - 32
  • [7] On lateral and upheaval buckling of subsea pipelines
    Karampour, Hassan
    Albermani, Faris
    Gross, Julien
    [J]. ENGINEERING STRUCTURES, 2013, 52 : 317 - 330
  • [8] Solution methods for the growth of a repeating imperfection in the line of a strut on a nonlinear foundation
    Lagrange, R.
    Averbuch, D.
    [J]. INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2012, 63 (01) : 48 - 58
  • [9] An analytical solution to lateral buckling control of subsea pipelines by distributed buoyancy sections
    Li, Gang
    Zhan, Lichao
    Li, Hao
    [J]. THIN-WALLED STRUCTURES, 2016, 107 : 221 - 230
  • [10] Laboratory tests and thermal buckling analysis for pipes buried in Bohai soft clay
    Liu, Run
    Basu, Prasenjit
    Xiong, Hao
    [J]. MARINE STRUCTURES, 2015, 43 : 44 - 60