Two-dimensional echocardiographic measures of left ventricular dimensions agree with M-mode measurements in dogs

被引:2
|
作者
Rishniw, M. [1 ,2 ]
Corda, A. [3 ]
Spina, F. [4 ]
Caivano, D. [5 ]
机构
[1] Cornell Univ, Coll Vet Med, Dept Clin Sci, Ithaca, NY 14853 USA
[2] Vet Informat Network, Davis, CA 95616 USA
[3] Univ Sassari, Dept Vet Med, Via Vienna 2, I-07100 Sassari, Italy
[4] Vet Hosp Etiopia, Rome, Italy
[5] Univ Perugia, Dept Vet Med, Via San Costanzo 4, I-06126 Perugia, Italy
关键词
Canine; Echocardiography; Cardiac mensuration; Cardiomegaly;
D O I
10.1016/j.jvc.2020.12.001
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Introduction: Clinicians measure left ventricular dimensions in dogs from both M-mode and two-dimensional images. Little information currently exists as to whether these two methods provide measurements similar enough to be interchangeable. Animals: The animals included in this study are 206 client-owned dogs: 68 healthy, 105 with myxomatous mitral valve disease, 33 with other cardiac or extracardiac disease. Materials and methods: Investigators measured left ventricular diastolic and systolic dimensions from archived M-mode and two-dimensional images obtained from the right parasternal short-axis view. Agreement between the pairs of measure-ments was examined using limits of agreement (Bland-Altman) plots. Results: Left ventricular diastolic dimensions showed no fixed or proportional bias but did show heteroscedasticity. Ninety-five percent limits of agreement for normalized differences approximated +/- 10%; 95% of the absolute differences for any pair of measurements were <3.9 mm regardless of bodyweight and <2.7 mm for dogs <15 kg. Left ventricular systolic dimensions showed slight proportional bias, with two-dimensional measurements being progressively larger than M-mode measurements as ventricular size increased. Ninety-five percent limits of agree-ment for normalized differences approximated +/- 20%; 95% of the absolute differ-ences for any pair of measurements were <4.6 mm regardless of bodyweight and <3.5 mm for dogs <15 kg. Mitral valve disease did not appreciably affect these find-ings. Conclusions: Left ventricular internal dimensions in dogs with and without cardiac disease measured from two-dimensional right parasternal short-axis images are in-terchangeable with those measured from M-mode images using the same view. (C) 2020 Published by Elsevier B.V.
引用
收藏
页码:69 / 75
页数:7
相关论文
共 50 条
  • [21] Normative Left Ventricular M-Mode Echocardiographic Values in Preterm Infants up to 2 kg
    Choudhry, Swati
    Salter, Amber
    Cunningham, Tyler W.
    Levy, Philip T.
    Nguyen, Hoang H.
    Wallendorf, Michael
    Singh, Gautam K.
    Johnson, Mark C.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2017, 30 (08) : 781 - +
  • [22] Two-dimensional, M-mode and Doppler-derived echocardiographic parameters in sedated healthy growing female sheep
    Poser, H.
    Semplicini, L.
    De Benedictis, G. M.
    Gerardi, G.
    Contiero, B.
    Maschietto, N.
    Valerio, E.
    Milanesi, O.
    Semplicini, A.
    Bernardini, D.
    LABORATORY ANIMALS, 2013, 47 (03) : 194 - 202
  • [23] Allometric scaling of M-mode cardiac measurements in normal adult dogs
    Cornell, CC
    Kittleson, MD
    Della Torre, P
    Häggström, J
    Lombard, CW
    Pedersen, HD
    Vollmar, A
    Wey, A
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2004, 18 (03) : 311 - 321
  • [24] Two-dimensional echocardiographic left-atrial-to-aortic ratio in healthy adult dogs: a reexamination of reference intervals
    Rishniw, M.
    Caivano, D.
    Dickson, D.
    Vatne, L.
    Harris, J.
    Matos, J. N.
    JOURNAL OF VETERINARY CARDIOLOGY, 2019, 26 : 29 - 38
  • [25] Two-Dimensional- and M-Mode Echocardiographic Measurements and Indices of Cardiac Function in Spanish Colts and Fillies of Different Age
    Rovirao, S.
    Munoz, A.
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2009, 71 (07) : 957 - 964
  • [26] Color M-Mode Echocardiography Derived Left Ventricular Diastolic Indices in Infants Strongly Correlate With Left Ventricular Linear Dimensions
    Erickson, Collin T.
    Meyers, Brett
    Li Ling
    Craft, Mary
    Vlachos, Pavlos
    Danford, David A.
    Kutty, Shelby
    CIRCULATION, 2018, 138
  • [27] M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHIC REFERENCE VALUES FOR THREE HUNGARIAN DOG BREEDS: HUNGARIAN VIZSLA, MUDI AND HUNGARIAN GREYHOUND
    Voros, Karoly
    Hetyey, Csaba
    Reiczigel, Jeno
    Czirok, Gabor Nagy
    ACTA VETERINARIA HUNGARICA, 2009, 57 (02) : 217 - 227
  • [28] COMPUTERIZED M-MODE ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN PATIENTS WITH FAMILIAL AMYLOID POLYNEUROPATHY
    HONGO, M
    MISAWA, T
    KINOSHITA, O
    YAMADA, H
    KONO, J
    OKUBO, S
    SEKIGUCHI, M
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1990, 54 (01): : 32 - 42
  • [29] Two-dimensional echocardiographic estimates of left atrial volumes obtained from two different views in dogs are similar but not interchangeable
    Caivano, D.
    Rishniw, M.
    Birettoni, F.
    Nisini, N.
    Porciello, F.
    VETERINARY JOURNAL, 2023, 293
  • [30] Left ventricular M-mode prediction intervals in 7651 dogs: Population-wide and selected breed-specific values
    Esser, Lilith Carla
    Borkovec, Martin
    Bauer, Alexander
    Haggstrom, Jens
    Wess, Gerhard