Four-corner fusion: comparison of patient satisfaction and functional outcome of conventional K-wire technique vs. a new locking plate

被引:23
作者
Hernekamp, J. F. [1 ]
Reinecke, A. [1 ]
Neubrech, F. [1 ]
Bickert, B. [1 ]
Kneser, U. [1 ]
Kremer, T. [1 ]
机构
[1] Heidelberg Univ, BG Trauma Ctr Ludwigshafen, Burn Ctr, Dept Hand Plast & Reconstruct Surg, Ludwig Guttmann Str 13, D-67061 Ludwigshafen, Germany
关键词
Limited wrist arthrodesis; Four-corner fusion; Locking plate; K-wires; SCAPHOLUNATE ADVANCED COLLAPSE; MIDCARPAL ARTHRODESIS; SCAPHOID NONUNION; WRIST ARTHRODESIS; SNAC-WRIST; COMPLICATIONS; INTERCARPAL; FIXATION;
D O I
10.1007/s00402-016-2416-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Four-corner fusion is a standard procedure for advanced carpal collapse. Several operative techniques and numerous implants for osseous fixation have been described. Recently, a specially designed locking plate (AptusA (c), Medartis, Basel, Switzerland) was introduced. The purpose of this study was to compare functional results after osseous fixation using K-wires (standard of care, SOC) with four-corner fusion and locking plate fixation. 21 patients who underwent four-corner fusion in our institution between 2008 and 2013 were included in a retrospective analysis. In 11 patients, osseous fixation was performed using locking plates whereas ten patients underwent bone fixation with conventional K-wires. Outcome parameters were functional outcome, osseous consolidation, patient satisfaction (DASH- and Krimmer Score), pain and perioperative morbidity and the time until patients returned to daily work. Patients were divided in two groups and paired t-tests were performed for statistical analysis. No implant related complications were observed. Osseous consolidation was achieved in all cases. Differences between groups were not significant regarding active range of motion (AROM), pain and function. Overall patient satisfaction was acceptable in all cases; differences in the DASH questionnaire and the Krimmer questionnaire were not significant. One patient of the plate group required conversion to total wrist arthrodesis without implant-related complications. Both techniques for four-corner fusion have similar healing rates. Using the more expensive locking implant avoids a second operation for K-wire removal, but no statistical differences were detected in functional outcome as well as in patient satisfaction when compared to SOC.
引用
收藏
页码:571 / 578
页数:8
相关论文
共 26 条
  • [1] SCAPHOLUNATE ADVANCED COLLAPSE WRIST SALVAGE
    ASHMEAD, D
    WATSON, HK
    DAMON, C
    HERBER, S
    PALY, W
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (05): : 741 - 750
  • [2] The Outcome of Scaphoid Excision and Four-Corner Arthrodesis for Advanced Carpal Collapse at a Minimum of Ten Years
    Bain, Gregory I.
    Watts, Adam C.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (05): : 719 - 725
  • [3] NEW DORSAL CAPSULOTOMY FOR THE SURGICAL EXPOSURE OF THE WRIST
    BERGER, RA
    BISHOP, AT
    BETTINGER, PC
    [J]. ANNALS OF PLASTIC SURGERY, 1995, 35 (01) : 54 - 59
  • [4] A prospective outcomes study of four-corner wrist arthrodesis using a circular limited wrist fusion plate for stage II scapholunate advanced collapse wrist deformity
    Chung, Kevin C.
    Watt, Andrew J.
    Kotsis, Sandra V.
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 118 (02) : 433 - 442
  • [5] Collins Evan D, 2008, Tech Hand Up Extrem Surg, V12, P94, DOI 10.1097/BTH.0b013e31815e4580
  • [6] Long-term results of midcarpal arthrodesis in the treatment of scaphoid nonunion advanced collapse (SNAC-wrist) and scapholunate advanced collapse (SLAC-wrist)
    Dacho, A
    Grundel, J
    Holle, G
    Germann, G
    Sauerbier, M
    [J]. ANNALS OF PLASTIC SURGERY, 2006, 56 (02) : 139 - 144
  • [7] Comparison of proximal row carpectomy and midcarpal arthrodesis for the treatment of scaphoid nonunion advanced collapse (SNAC-wrist) and scapholunate advanced collapse (SLAC-wrist) in stage II
    Dacho, Andreas K.
    Baumeister, Steffen
    Germann, Guenter
    Sauerbier, Michael
    [J]. JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2008, 61 (10) : 1210 - 1218
  • [8] Variable Angle Locking Intercarpal Fusion System for Four-Corner Arthrodesis: Indications and Surgical Technique
    del Pino, Juan Gonzalez
    Campbell, Douglas
    Fischer, Thomas
    Vazquez, Fiesky Nunez
    Jupiter, Jesse B.
    Nagy, Ladislav
    [J]. JOURNAL OF WRIST SURGERY, 2012, 1 (01) : 73 - 78
  • [9] Friedel R, 2011, OPER ORTHOP TRAUMATO, V23, P98, DOI 10.1007/s00064-011-0020-3
  • [10] A modified technique of four-bone fusion for advanced carpal collapse (SLAC/SNAC wrist)
    Garcia-López, A
    Perez-Ubeda, MJ
    Marco, F
    Molina, M
    López-Durant, L
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2001, 26 (04) : 352 - 354