Multi-site analytical evaluation of a chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the Abbott ARCHITECT analyzer

被引:32
|
作者
Schmid, Rainer W. [2 ]
Lotz, Johannes [3 ]
Schweigert, Rosemarie [3 ]
Lackner, Karl [3 ]
Aimo, Giuseppe [4 ]
Friese, Judith [1 ]
Rosiere, Thomas [1 ]
Dickson, Diana [5 ]
Kenney, Daniel [5 ]
Maine, Gregory T. [1 ]
机构
[1] Abbott Diagnost, Dept 09L5, Abbott Pk, IL 60064 USA
[2] Med Univ Vienna, Vienna, Austria
[3] Johannes Gutenberg Univ Mainz, Mainz, Germany
[4] Molinette Mauriziano Hosp, Turin, Italy
[5] Fujirebio Diagnost, Malvern, PA USA
关键词
Sirolimus; Rapamycin; Transplant; Immunoassay; CMIA; MEIA; LC/MS/MS; IMx; Monitoring; Immunosuppression; MASS-SPECTROMETRIC DETECTION; WHOLE-BLOOD; CALCINEURIN INHIBITORS; RAPAMYCIN; HPLC; TRANSPLANTATION; METABOLITES; MS/MS; ASSAY;
D O I
10.1016/j.clinbiochem.2009.06.018
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective: This study evaluated a new chemiluminescent magnetic microparticle immunoassay (CMIA) for sirolimus on the ARCHITECT analyzer. Design and methods: Patient and laboratory proficiency samples were tested at three European sites and one site in the United States. Results: The CMIA total %CV's were all <8% and the Limit of Quantification (LOQ) was <1.52 ng/mL across the four sites. It cross-reacts to sirolimus metabolites F4 and F5 and showed no hematocrit interference over a range of 25% to 55%. Patient specimen correlations to three LC/MS/MS methods gave R >= 0.91 at three sites and mean biases of 14%, 25% and 39%. CMIA patient specimen correlations to the Abbott IMx gave R >= 0.94 at 2 sites and mean biases of 5.4% and 6.9%. Conclusions: CMIA is a precise and sensitive immunoassay method without hematocrit interference. It correlates well to both LC/MS/MS and immunoassay results, but shows an expected positive bias to LC/MS/MS. (C) 2009 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1543 / 1548
页数:6
相关论文
共 7 条
  • [1] Multi-center evaluation of analytical performance of the microparticle enzyme immunoassay for sirolimus
    Wilson, D
    Johnston, F
    Holt, D
    Moreton, M
    Engelmayer, J
    Gaulier, JM
    Luthe, H
    Marquet, P
    Moscato, D
    Oellerich, M
    Mosso, R
    Streit, F
    Brunet, M
    Fillee, C
    Schmid, R
    Wallemacq, P
    Barnes, G
    CLINICAL BIOCHEMISTRY, 2006, 39 (04) : 378 - 386
  • [2] Multi-site Analytical Evaluation of the Abbott ARCHITECT Tacrolimus Assay
    Wallemacq, Pierre
    Goffinet, Jean-Sebastien
    O'Morchoe, Susan
    Rosiere, Thomas
    Maine, Gregory T.
    Labalette, Myriam
    Aimo, Giuseppe
    Dickson, Diana
    Schmidt, Ed
    Schwinzer, Reinhard
    Schmid, Rainer W.
    THERAPEUTIC DRUG MONITORING, 2009, 31 (02) : 198 - 204
  • [3] Multi-Site, Multi-Country Evaluation of Analytical and Operational Performance of a Low-Mid Volume Chemiluminescent Immunoassay Analyzer
    De Keijzer, M. H.
    Perkins, S.
    Motta, V
    Morelli, D.
    Cristol, J. P.
    Dupuy, A. M.
    Hong, Y.
    Watanabe, S.
    Waerdt, C.
    Grunewald, R. W.
    CLINICAL LABORATORY, 2009, 55 (9-10) : 363 - 370
  • [4] Evaluation of the Abbott Alinity i Thyroid-Stimulating Hormone Receptor Antibody (TRAb) Chemiluminescent Microparticle Immunoassay (CMIA)
    Lee, Deborah J. W.
    Phua, Soon Kieng
    Liang, Yali
    Chen, Claire
    Aw, Tar-Choon
    DIAGNOSTICS, 2023, 13 (16)
  • [5] Evaluation of a microparticle enzyme immunoassay for the measurement of sirolimus in whole blood (Abbott IMx sirolimus)
    Scholer, Andre
    Von Rickenbach, Richard
    Faffa, Genevieve
    Vetter, Beatrice
    CLINICAL LABORATORY, 2006, 52 (7-8) : 325 - 334
  • [6] Determination of everolimus in blood samples from kidney and liver transplant recipients using the sirolimus chemiluminescence magnetic microparticle immunoassay (CMIA) on the Architect-i1000® System
    Hermida-Cadahia, Esperanza F.
    Carlos Tutor, J.
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2012, 72 (02) : 180 - 183
  • [7] Analytical and clinical performance evaluation of the Wantai chemiluminescence microparticle immunoassay on the Wan200 + analyzer for diagnosing HIV
    Jianfeng Chen
    Liyue Jiang
    Ran Ju
    Yitong Li
    Fengtian Wang
    Scientific Reports, 15 (1)