Accurate and robust modeling of the characteristic I-V curve of a photovoltaic module is essential in many applications focused on forecasting and predicting photovoltaic (PV) performance. The single diode equivalent model has been used extensively for representing the working principles of solar cells. This work presents a simple methodology for solving the single diode equation from the manufacture's datasheet parameters, by combining the Lambert-W function and an iterative procedure on the ideality factor of the diode, which has a fast convergence and robustness. The model has been assessed by comparing with experimental I-V curves measured for different modules at indoor and outdoor conditions with good results. Sensitivity analysis has been also done to indicate the possible impact of the uncertainty of the initial parameters that input the model.
引用
收藏
页码:1004 / 1011
页数:8
相关论文
共 33 条
  • [1] Andrews RW, 2014, 40 IEEE PHOT SPEC C
  • [2] [Anonymous], 2017, T13062017 IEAPVPS
  • [3] [Anonymous], THESIS
  • [4] Evaluation of numerical algorithms used in extracting the parameters of a single-diode photovoltaic model
    Ayodele, T. R.
    Ogunjuyigbe, A. S. O.
    Ekoh, E. E.
    [J]. SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2016, 13 : 51 - 59
  • [5] Parameter extraction of two diode solar PV model using Fireworks algorithm
    Babu, T. Sudhakar
    Ram, J. Prasanth
    Sangeetha, K.
    Laudani, Antonino
    Rajasekar, N.
    [J]. SOLAR ENERGY, 2016, 140 : 265 - 276
  • [6] Modelling and experimental verification of the operating current of mono-crystalline photovoltaic modules using four- and five-parameter models
    Celik, Ali Naci
    Acikgoz, Nasir
    [J]. APPLIED ENERGY, 2007, 84 (01) : 1 - 15
  • [7] A comparison of different one-diode models for the representation of I-V characteristic of a PV cell
    Ciulla, Giuseppina
    Lo Brano, Valerio
    Di Dio, Vincenzo
    Cipriani, Giovanni
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 32 : 684 - 696
  • [8] Explicit Expressions for Solar Panel Equivalent Circuit Parameters Based on Analytical Formulation and the Lambert W-Function
    Cubas, Javier
    Pindado, Santiago
    de Manuel, Carlos
    [J]. ENERGIES, 2014, 7 (07) : 4098 - 4115
  • [9] Improvement and validation of a model for photovoltaic array performance
    De Soto, W
    Klein, SA
    Beckman, WA
    [J]. SOLAR ENERGY, 2006, 80 (01) : 78 - 88
  • [10] Dobos A. P., 2014, Report No