Influence of implant surface topography on early osseointegration: A histological study in human jaws

被引:69
作者
Shibli, Jamil Awad [1 ]
Grassi, Sauro
de Figueiredo, Luciene Cristina
Feres, Magda
Marcantonio, Elcio, Jr.
Iezzi, Giovanna
Piattelli, Adriano
机构
[1] Univ Guarulhos, Dent Res Div, Dept Periodont, Sao Paulo, Brazil
[2] Univ Estadual Paulista, Sao Paulo State Univ, Dept Periodontol, Dent Sch Araraquara, Sao Paulo, Brazil
[3] Univ G dAnnunzio, Sch Dent, Dept Oral Med & Oral Pathol, Chieti, Italy
关键词
dental implants; implant surface topography; osseointegration; wound healing; human histology;
D O I
10.1002/jbm.b.30608
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to evaluate the influence of the oxidized surface on bone-to-implant contact (BIC%), the bone density in the threaded area (BA %), as well as the bone density outside the threaded area (BD%) in human jaws after 2 months of unloaded healing. Thirteen subjects (mean age 42.61 +/- 6.15 years) received two microimplants (2.5 mm diameter and 6 mm length) each, during conventional mandible or maxilla implant surgery. The microimplants with commercially pure titanium surfaces (machined) and oxidized surfaces served as the control and test surfaces, respectively. After 2 months, the microimplants and the surrounding tissue were removed and prepared for histomorphometric analysis. All microimplants, except two machined and one oxidized microimplant surfaces, were found to be clinically stable after the healing period. Histometric evaluation indicated that the mean BIC % was (21.71 +/- 13.11) % and (39.04 +/- 15.75) % for machined and oxidized microimplant surfaces, respectively. The BD% was higher for the oxidized surface, although there was no difference for maxilla and mandible. The oxidized surface impacted the BA% for the type-IV bone. Data suggest that the oxidized surface presented a higher bone-to-implant contact rate compared with machined surfaces under unloaded conditions, after a healing period of 2 months. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:377 / 385
页数:9
相关论文
共 46 条
[21]  
IVANOFF CJ, 1999, THESIS GOTEBORG U GO
[22]   THE EXCESSIVE LOSS OF BRANEMARK FIXTURES IN TYPE-IV BONE - A 5-YEAR ANALYSIS [J].
JAFFIN, RA ;
BERMAN, CL .
JOURNAL OF PERIODONTOLOGY, 1991, 62 (01) :2-4
[23]   IMPLANT TREATMENT IN RESORBED EDENTULOUS UPPER JAWS - A 3-YEAR FOLLOW-UP-STUDY ON 70 PATIENTS [J].
JEMT, T .
CLINICAL ORAL IMPLANTS RESEARCH, 1993, 4 (04) :187-194
[24]  
Jemt T, 1996, Int J Oral Maxillofac Implants, V11, P291
[25]   Oxidized titanium implants (Nobel Biocare® TiUnite™) compared with turned titanium implants (Nobel Biocare® mark III™) with respect to implant failure in a group of consecutive patients treated with early functional loading and two-stage protocol [J].
Jungner, M ;
Lundqvist, P ;
Lundgren, S .
CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (03) :308-312
[26]   Human histological research: Is it necessary? Humane? Ethical? [J].
Leib, AM ;
Kowalski, CJ .
JOURNAL OF PERIODONTOLOGY, 2005, 76 (07) :1207-1210
[27]  
Lumbikanonda N, 2001, INT J ORAL MAX IMPL, V16, P627
[28]  
MEYER A E, 1988, Journal of Oral Implantology, V14, P363
[29]  
Morris Harold F, 2004, J Oral Implantol, V30, P125, DOI 10.1563/1548-1336(2004)30<125:APIAYM>2.0.CO
[30]  
2