Influence of implant surface topography on early osseointegration: A histological study in human jaws

被引:69
作者
Shibli, Jamil Awad [1 ]
Grassi, Sauro
de Figueiredo, Luciene Cristina
Feres, Magda
Marcantonio, Elcio, Jr.
Iezzi, Giovanna
Piattelli, Adriano
机构
[1] Univ Guarulhos, Dent Res Div, Dept Periodont, Sao Paulo, Brazil
[2] Univ Estadual Paulista, Sao Paulo State Univ, Dept Periodontol, Dent Sch Araraquara, Sao Paulo, Brazil
[3] Univ G dAnnunzio, Sch Dent, Dept Oral Med & Oral Pathol, Chieti, Italy
关键词
dental implants; implant surface topography; osseointegration; wound healing; human histology;
D O I
10.1002/jbm.b.30608
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to evaluate the influence of the oxidized surface on bone-to-implant contact (BIC%), the bone density in the threaded area (BA %), as well as the bone density outside the threaded area (BD%) in human jaws after 2 months of unloaded healing. Thirteen subjects (mean age 42.61 +/- 6.15 years) received two microimplants (2.5 mm diameter and 6 mm length) each, during conventional mandible or maxilla implant surgery. The microimplants with commercially pure titanium surfaces (machined) and oxidized surfaces served as the control and test surfaces, respectively. After 2 months, the microimplants and the surrounding tissue were removed and prepared for histomorphometric analysis. All microimplants, except two machined and one oxidized microimplant surfaces, were found to be clinically stable after the healing period. Histometric evaluation indicated that the mean BIC % was (21.71 +/- 13.11) % and (39.04 +/- 15.75) % for machined and oxidized microimplant surfaces, respectively. The BD% was higher for the oxidized surface, although there was no difference for maxilla and mandible. The oxidized surface impacted the BA% for the type-IV bone. Data suggest that the oxidized surface presented a higher bone-to-implant contact rate compared with machined surfaces under unloaded conditions, after a healing period of 2 months. (c) 2006 Wiley Periodicals, Inc.
引用
收藏
页码:377 / 385
页数:9
相关论文
共 46 条
[1]   Early bone formation adjacent to rough and turned endosseous implant surfaces - An experimental study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Linder, E ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :381-392
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]  
Albrektsson T, 2001, Clin Implant Dent Relat Res, V3, P174
[4]  
Buser D, 1998, INT J ORAL MAX IMPL, V13, P611
[5]   INFLUENCE OF SURFACE CHARACTERISTICS ON BONE INTEGRATION OF TITANIUM IMPLANTS - A HISTOMORPHOMETRIC STUDY IN MINIATURE PIGS [J].
BUSER, D ;
SCHENK, RK ;
STEINEMANN, S ;
FIORELLINI, JP ;
FOX, CH ;
STICH, H .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1991, 25 (07) :889-902
[6]   Long-term evaluation of non-submerged ITI implants .1. 8-year life table analysis of a prospective multi-center study with 2359 implants [J].
Buser, D ;
MericskeStern, R ;
Bernard, JP ;
Behneke, A ;
Behneke, N ;
Hirt, HP ;
Belser, UC ;
Lang, NP .
CLINICAL ORAL IMPLANTS RESEARCH, 1997, 8 (03) :161-172
[7]  
Buser D, 1999, PROCEEDINGS OF THE 3RD EUROPEAN WORKSHOP ON PERIODONTOLOGY: IMPLANT DENTISTRY, P88
[8]  
Davies JE, 1998, INT J PROSTHODONT, V11, P391
[9]   EFFECT OF PARALLEL SURFACE MICROGROOVES AND SURFACE-ENERGY ON CELL-GROWTH [J].
DENBRABER, ET ;
DERUIJTER, JE ;
SMITS, HTJ ;
GINSEL, LA ;
VONRECUM, AF ;
JANSEN, JA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (04) :511-518
[10]  
DHOEDT B, 1985, CURRENT CLIN PRACTIC, V29, P46