Low-Profile Visualized Intraluminal Support Jr Braided Stent Versus Atlas Self-Expandable Stent for Treatment of Intracranial Aneurysms: A Single Center Experience

被引:10
|
作者
Monteiro, Andre [1 ]
Cortez, Gustavo M. [1 ]
Aghaebrahim, Amin [1 ]
Sauvageau, Eric [1 ]
Hanel, Ricardo A. [1 ]
机构
[1] Baptist Neurol Inst, Lyerly Neurosurg, Jacksonville, FL USA
关键词
Aneurysm; Ruptured; Angioplasty; Intracranial aneurysm; Stents; ASSISTED COILING; LVIS JR; EMBOLIZATION; DEVICE; SAFETY;
D O I
10.1093/neuros/nyaa458
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: The Neuroform Atlas Stent and Low-profile Visualized Intraluminal Support (LVIS) and LVIS Jr stents are used to treat intracranial aneurysms (IAs), but their safety, performance, and outcomes have not been directly compared. OBJECTIVE: To compare the technical performance and outcomes of Atlas and LVIS Jr stents for treatment of IAs. METHODS: IAs treated by stent-assisted coiling using an Atlas (Stryker, Kalamazoo, Michigan) or LVIS Jr (MicroVention, Aliso Viejo, California) device between January 2014 to November 2019 were retrospectively evaluated. Patient demographics, aneurysm size and location, technical difficulties, and clinical and angiographic follow-up were analyzed. RESULTS: A total of 116 patients, (mean age 64.2 11.8 yr, 72.7% female) with 121 aneurysms underwent stent-assisted coiling with deployment of Atlas (n = 64) or LVIS Jr (n = 57) stents. Mean aneurysm size was 6.2 +/- 2.7 mm. Immediate rates of Raymond-Roy (RR) 1/2 were 89.0% (57/64) and 80.7% (46/57) for the Atlas and LVIS Jr groups, respectively. Neither group had major postoperative thromboembolic complications; however, 15.8% (9/57) of the LVIS Jr procedures had technical issues. Additionally, 88.5% (46/52) and 91.2% (33/36) of patients in the Atlas and LVIS Jr groups had RR 1/2 at a mean follow-up of 13.6 and 18.7 mo, respectively. CONCLUSION: Treatment of IAs with Atlas and LVIS Jr stents results in favorable clinical outcomes and angiographic results at follow-up, with low rates of recurrence and retreatment, suggesting both devices are safe and effective. Notably, LVIS Jr had more technical problems than Atlas.
引用
收藏
页码:E170 / E178
页数:9
相关论文
共 50 条
  • [21] Treatment of basilar artery aneurysms with two braided stents: Two centers experience of low-profile visualized intraluminal support stents versus Pipeline flow diverters
    Luo, Bin
    Wang, Chao
    Liu, Jian
    Zhang, Yisen
    Wang, Kun
    Li, Wenqiang
    Zhang, Ying
    NEURORADIOLOGY JOURNAL, 2024, 37 (04) : 500 - 509
  • [22] Endovascular Intervention with a Low-profile Visualized Intraluminal Support Stent Versus Surgical Clipping for Blood Blister-like Aneurysms A Retrospective Study
    Wu, Ya-Qiu
    Li, Li-Zhi
    Wang, Zhen-Yu
    Zhang, Tian
    Xu, Min
    Cheng, Mei-Xiong
    CLINICAL NEURORADIOLOGY, 2021, 31 (02) : 417 - 424
  • [23] Intracranial Complex Ruptured Aneurysms Coiled with Overlapping Low-Profile Visualized Intraluminal Support Stents: Another Available Option for Complex Ruptured Intracranial Aneurysms
    Yan, Zhiyuan
    Zheng, Kuang
    Xiong, Ye
    Lan, Fujun
    Wang, Yunhui
    Tan, Xianxi
    Zhong, Ming
    Li, Zequn
    WORLD NEUROSURGERY, 2019, 125 : E22 - E28
  • [24] Endovascular treatment of vertebral and basilar artery aneurysms with low-profile visualized intraluminal support device
    Hong, Quanlong
    Li, Wenqiang
    Ma, Jing
    Jiang, Peng
    Zhang, Yisen
    BMC NEUROLOGY, 2021, 21 (01)
  • [25] Endovascular Treatment of Wide-Necked Intracranial Aneurysms with the Scepter XC Balloon Catheter, with Low-Profile Visualized Intraluminal Support (LVIS) Jr. Deployment as a "Bailout" Technique
    Wallace, Adam N.
    Kayan, Yasha
    Almandoz, Josser E. Delgado
    Fease, Jennifer L.
    Milner, Anna A.
    Scholz, Jill M.
    WORLD NEUROSURGERY, 2019, 121 : E798 - E807
  • [26] Utility of Low-Profile Visualized Intraluminal Support Junior Stent as a Rescue Therapy for Treating Ruptured Intracranial Aneurysms During Complicated Coil Embolization
    Kim, Seung Soo
    Park, Hyun
    Lee, Kwang Ho
    Jung, Seunguk
    Yoon, Chang Hyo
    Kim, Sung Kwon
    Ryu, Kyeong Hwa
    Baek, Hye Jin
    Hwang, Soo Hyun
    Kwon, O-Ki
    WORLD NEUROSURGERY, 2020, 135 : e710 - e715
  • [27] Endovascular treatment of patients with intracranial aneurysms: feasibility and successful employment of a new low profile visible intraluminal support (LVIS) EVO stent
    Sirakov, Alexander
    Bhogal, Pervinder
    Mohlenbruch, Markus
    Sirakov, Stanimir
    NEURORADIOLOGY JOURNAL, 2020, 33 (05) : 377 - 385
  • [28] Coil embolization of intracranial saccular aneurysms using the Low-profile Visualized Intraluminal Support (LVIS™) device
    Young Dae Cho
    Chul-Ho Sohn
    Hyun-Seung Kang
    Jeong Eun Kim
    Won-Sang Cho
    Gyojun Hwang
    O-Ki Kwon
    Mi-Sun Ko
    Nam-Mi Park
    Moon Hee Han
    Neuroradiology, 2014, 56 : 543 - 551
  • [29] Coil embolization of intracranial saccular aneurysms using the Low-profile Visualized Intraluminal Support (LVIS™) device
    Cho, Young Dae
    Sohn, Chul-Ho
    Kang, Hyun-Seung
    Kim, Jeong Eun
    Cho, Won-Sang
    Hwang, Gyojun
    Kwon, O-Ki
    Ko, Mi-Sun
    Park, Nam-Mi
    Han, Moon Hee
    NEURORADIOLOGY, 2014, 56 (07) : 543 - 551
  • [30] Low-Profile Visualized Intraluminal Support Stent-Only Technique for Intracranial Aneurysms-A Report of 12 Cases with Midterm Follow-Up
    Liu, Qinglin
    Qi, Changjing
    Zhang, Yupeng
    Deng, Lin
    Li, Gang
    Su, Wandong
    WORLD NEUROSURGERY, 2019, 129 : E40 - E47