Bidirectional isotachophoresis on a planar chip with integrated conductivity detection

被引:45
|
作者
Prest, JE [1 ]
Baldock, SJ [1 ]
Fielden, PR [1 ]
Goddard, NJ [1 ]
Brown, BJT [1 ]
机构
[1] UMIST, Dept Instrumentat & Analyt Sci, Manchester M60 1QD, Lancs, England
关键词
D O I
10.1039/b207462a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of a miniaturised planar separation device with integrated conductivity detection for performing bidirectional isotachophoresis (ITP) is described. The chips were produced in poly( methyl methacrylate) (PMMA) using a milling procedure. To enable bidirectional ITP the devices were designed to inject samples into the centre of the separation channel and incorporated two integrated on-column conductivity detectors, positioned at opposite ends of this channel. When used with a hydrodynamic sample transport system the devices were used for the analysis of a range of small ions: NH4+; Na+; Mg2+; Ca2+; Li+; NO3-; ClO4-; SO41; F-. Results successfully achieved included the simultaneous separation of three anions and three cations.
引用
收藏
页码:1413 / 1419
页数:7
相关论文
共 50 条
  • [31] Isotachophoresis preconcentration integrated microfluidic chip for highly sensitive genotyping of the hepatitis B virus
    Liu, Dayu
    Shi, Ming
    Huang, Huaiqing
    Long, Zhicheng
    Zhou, Xiaomian
    Qin, Jianhua
    Lin, Bingcheng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 844 (01): : 32 - 38
  • [32] ANALYSIS OF PHARMACEUTICAL SUBSTANCES BY ISOTACHOPHORESIS ON A CHIP
    Rudasova, Marina
    Joanidisova, Michaela
    Radicova, Zdenka
    Bodor, Robert
    Masar, Marian
    CECE 2012: 9TH INTERNATIONAL INTERDISCIPLINARY MEETING ON BIOANALYSIS, 2012, : 276 - 282
  • [33] Isotachophoresis on a chip with indirect fluorescence detection as a field deployable system for analysis of carboxylic acids
    Smejkal, Petr
    Breadmore, Michael C.
    Guijt, Rosanne M.
    Foret, Frantisek
    Bek, Fritz
    Macka, Mirek
    ELECTROPHORESIS, 2012, 33 (21) : 3166 - 3172
  • [34] Study of capillary electrophoresis chip with Conductivity detection
    Wang, Wei
    Tian, Li
    Liu, Xiao-Wei
    Xuan, Lei
    MEMS, MOEMS, AND MICROMACHINING II, 2006, 6186
  • [35] Compact photonic integrated circuit chip with low crosstalk for bidirectional transceivers
    Park, KS
    Oh, DK
    Kim, HM
    Pyun, KE
    ELECTRONICS LETTERS, 1998, 34 (01) : 79 - 80
  • [36] Compact photonic integrated circuit chip with low crosstalk for bidirectional transceivers
    Semiconductor Technology Division, Electronics and Telecom. Res. Inst., 161 Kajung-Dong, Yusong-Gu, Taejon 305-350, Korea, Republic of
    Electron Lett, 1 (79-80):
  • [37] A bidirectional module integrated on a planar lightwave circuit with a coated WDM filter
    Rho, Byung Sup
    Hwang, Sung Hwan
    Lim, JungWoon
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (03)
  • [38] ISOTACHOPHORESIS - CONDUCTIVITY MEASUREMENT AND SIGNAL HANDLING
    MULDER, AJ
    ZUSKA, J
    JOURNAL OF CHROMATOGRAPHY, 1974, 91 (APR24): : 819 - 822
  • [39] Planar FRET detection from biomolecules on an optofluidic chip
    Chen, A.
    Measor, P.
    Lunt, E. J.
    Phillips, B. S.
    Hawkins, A. R.
    Schmidt, H.
    SILICON PHOTONICS V, 2010, 7606
  • [40] Concentration cascade of leading electrolyte using bidirectional isotachophoresis
    Bahga, Supreet S.
    Santiago, Juan G.
    ELECTROPHORESIS, 2012, 33 (06) : 1048 - 1059