Multishot Targeted PROPELLER Magnetic Resonance Imaging Description of the Technique and Initial Applications

被引:8
作者
Deng, Jie [1 ,2 ]
Larson, Andrew C. [1 ,2 ]
机构
[1] Northwestern Univ, Dept Radiol, Chicago, IL 60611 USA
[2] Northwestern Univ, Dept Biomed Engn, Chicago, IL 60611 USA
关键词
PROPELLER; targeted; inner-volume-imaging; reduced FOV; HIGH-RESOLUTION DTI; MRI; ENHANCEMENT; INFARCTION; SEQUENCE; ABDOMEN;
D O I
10.1097/RLI.0b013e3181a8b015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To test the feasibility of combining inner-volume imaging (IVI) techniques with conventional multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) techniques for targeted-PROPELLER magnetic resonance imaging. Materials and Methods: Perpendicular section-selective gradients for spatially selective excitation and refocusing RF pulses were applied to limit the refocused field-of-view (FOV) along the phase-encoding direction for each rectangular blade image. We performed comparison studies in phantoms and normal volunteers by using targeted-PROPELLER methods for a wide range of imaging applications that commonly use turbo-spin-echo (TSE) approaches (brain, abdominal, vessel wall, cardiac). Results: In these initial studies, we demonstrated the feasibility of using targeted-PROPELLER approaches to limit the imaging FOV thereby reducing the number of blades or permitting increased spatial resolution without commensurate increases in scan time. Both phantom and in vivo motion studies demonstrated the potential for more robust regional self-navigated motion correction compared with conventional full FOV PROPELLER methods. Conclusion: We demonstrated that the reduced FOV targeted-PROPELLER technique offers the potential for reducing imaging time, increasing spatial resolution, and targeting specific areas for robust regional motion correction.
引用
收藏
页码:454 / 462
页数:9
相关论文
共 29 条
[1]   Depiction of the cranial nerves within the brain stem with use of PROPELLER multishot diffusion weighted imaging [J].
Adachi, M. ;
Kabasawa, H. ;
Kawaguchi, E. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) :911-912
[2]   k-space undersampling in PROPELLER imaging [J].
Arfanakis, K ;
Tamhane, AA ;
Pipe, JG ;
Anastasio, MA .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) :675-683
[3]   T1-Weighted Brain Imaging With a 32-Channel Coil at 3T Using TurboFLASH BLADE Compared With Standard Cartesian k-Space Sampling [J].
Attenberger, Ulrike I. ;
Runge, Val M. ;
Williams, Kenneth D. ;
Stemmer, Alto ;
Michaely, Henrik J. ;
Schoenberg, Stefan O. ;
Reiser, Maximilian F. ;
Wintersperger, Bernd J. .
INVESTIGATIVE RADIOLOGY, 2009, 44 (03) :177-183
[4]   DRIVEN EQUILIBRIUM FOURIER TRANSFORM SPECTROSCOPY . A NEW METHOD FOR NUCLEAR MAGNETIC RESONANCE SIGNAL ENHANCEMENT [J].
BECKER, ED ;
FERRETTI, JA ;
FARRAR, TC .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1969, 91 (27) :7784-&
[5]   MB-guided biopsy using a T2-weighted single-shot zoom imaging sequence (Local Look technique) [J].
Buecker, A ;
Adam, G ;
Neuerburg, JM ;
Glowinski, A ;
van Vaals, JJ ;
Guenther, RW .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (04) :955-959
[6]  
Busse RF, 2000, MAGN RESON MED, V44, P339, DOI 10.1002/1522-2594(200009)44:3<339::AID-MRM1>3.0.CO
[7]  
2-N
[8]   Multishot diffusion-weighted SPLICE PROPELLER MRI of the abdomen [J].
Deng, Jie ;
Omary, Reed A. ;
Larson, Andrew C. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) :947-953
[9]   Multishot diffusion-weighted PROPELLER magnetic resonance imaging of the abdomen [J].
Deng, Jie ;
Miller, Frank H. ;
Salem, Riad ;
Omary, Reed A. ;
Larson, Andrew C. .
INVESTIGATIVE RADIOLOGY, 2006, 41 (10) :769-775
[10]  
Devaraj A., 2007, P INT SOC MAG RESON, V15, P1665