Electrocardiographic changes and conduction disturbances after transfemoral aortic valve implantation with Edwards Sapien 3 prosthesis

被引:10
作者
Leire, Unzue [1 ]
Eulogio, Garcia [1 ]
Francisco Jose, Rodriguez Rodrigo [2 ]
Francisco Javier, Parra Jimenez [2 ]
Peralta Juan, Medina [2 ]
Belen, Diaz-Anton [3 ]
del Rio Miguel, Rodriguez [4 ]
Adolfo, Fontenla [5 ]
Rodrigo, Teijeiro [1 ]
Belen, Rubio-Alonso [2 ]
机构
[1] Hosp Univ HM Monteprincipe, Intervent Cardiol Dept, Ave Monteprincipe 25, Madrid 28668, Spain
[2] Hosp Univ HM Monteprincipe, Clin Cardiol Dept, Madrid, Spain
[3] Hosp Univ HM Monteprincipe, Cardiac Imaging Unit, Madrid, Spain
[4] Hosp Univ HM Monteprincipe, Anaesthesiol Dept, Madrid, Spain
[5] Hosp Univ 12 Octubre, Electrophysiol Dept, Madrid, Spain
关键词
Conduction disturbances; TAVI; Edwards SAPIEN prosthesis; PERMANENT PACEMAKER; TRANSCATHETER; PREDICTORS; BLOCK; RISK; REPLACEMENT; MANAGEMENT;
D O I
10.1016/j.jelectrocard.2018.02.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The aim of this study is to describe electrocardiographic changes and conduction abnormalities in patients undergoing transcatheter aortic valve implantation (TAVI). Methods: 76 patients who underwent TAVI using Edwards Sapien 3 prosthesis were included, comparing electrocardiographic registries at admission, post-procedure and before discharge. Results: Patients after TAVI presented a longer PR interval, a wider QRS, and a longer corrected QT, with a left deviation of QRS axis and T waves: reversible changes that tended to correct in the following days after TAVI. Complete atrioventricular block incidence was 2.9%. New-onset left bundle branch block (LBBB) incidence was 39%, although solved in almost half of patients before discharge. Conclusions: TAVI was associated with different reversible electrocardiographic changes that suggest a transient impact on the conduction system. One of every five patients presented permanent LBBB after valve implant. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:416 / 421
页数:6
相关论文
共 24 条
[11]  
Koos R, 2011, J HEART VALVE DIS, V20, P83
[12]   Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience [J].
Kostopoulou, Anna ;
Karyofillis, Panagiotis ;
Livanis, Efthimios ;
Thomopoulou, Sofia ;
Stefopoulos, Christos ;
Doudoumis, Konstantinos ;
Theodorakis, Georgios ;
Voudris, Vassilios .
EUROPACE, 2016, 18 (01) :131-137
[13]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607
[14]   Transcatheter Aortic Valve Implantation Review of the Nature, Management, and Avoidance of Procedural Complications [J].
Masson, Jean-Bernard ;
Kovac, Jan ;
Schuler, Gerhard ;
Ye, Jian ;
Cheung, Anson ;
Kapadia, Samir ;
Tuzcu, Murat E. ;
Kodali, Susheel ;
Leon, Martin B. ;
Webb, John G. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (09) :811-820
[15]  
Nuis RJ, 2015, J GERIATR CARDIOL, V12, P482, DOI 10.11909/j.issn.1671-5411.2015.05.016
[16]   Atrioventricular Conduction Disturbance Characterization in Transcatheter Aortic Valve Implantation With the CoreValve Prosthesis [J].
Rubin, Jose M. ;
Avanzas, Pablo ;
del Valle, Raquel ;
Renilla, Alfredo ;
Rios, Enrique ;
Calvo, David ;
Lozano, Inigo ;
Anguera, Ignasi ;
Diaz-Molina, Beatriz ;
Cequier, Angel ;
Moris de la Tassa, Cesar .
CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2011, 4 (03) :280-286
[17]   Short-term pacemaker dependency after transcatheter aortic valve implantation [J].
Schernthaner, Christiana ;
Kraus, Johannes ;
Danmayr, Franz ;
Hammerer, Matthias ;
Schneider, Jens ;
Hoppe, Uta C. ;
Strohmer, Bernhard .
WIENER KLINISCHE WOCHENSCHRIFT, 2016, 128 (5-6) :198-203
[18]   Transcatheter versus Surgical Aortic-Valve Replacement in High-Risk Patients [J].
Smith, Craig R. ;
Leon, Martin B. ;
Mack, Michael J. ;
Miller, Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Williams, Mathew ;
Dewey, Todd ;
Kapadia, Samir ;
Babaliaros, Vasilis ;
Thourani, Vinod H. ;
Corso, Paul ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 364 (23) :2187-2198
[19]   Regression of ventricular repolarisation inhomogeneity after aortic bileaflet valve replacement in patients with aortic stenosis [J].
Tsai, CH ;
Lee, TM ;
Su, SF .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 70 (02) :141-148
[20]  
Unzue L, 2017, CARDIOVASC IN PRESS