Electrocardiographic changes and conduction disturbances after transfemoral aortic valve implantation with Edwards Sapien 3 prosthesis

被引:8
作者
Leire, Unzue [1 ]
Eulogio, Garcia [1 ]
Francisco Jose, Rodriguez Rodrigo [2 ]
Francisco Javier, Parra Jimenez [2 ]
Peralta Juan, Medina [2 ]
Belen, Diaz-Anton [3 ]
del Rio Miguel, Rodriguez [4 ]
Adolfo, Fontenla [5 ]
Rodrigo, Teijeiro [1 ]
Belen, Rubio-Alonso [2 ]
机构
[1] Hosp Univ HM Monteprincipe, Intervent Cardiol Dept, Ave Monteprincipe 25, Madrid 28668, Spain
[2] Hosp Univ HM Monteprincipe, Clin Cardiol Dept, Madrid, Spain
[3] Hosp Univ HM Monteprincipe, Cardiac Imaging Unit, Madrid, Spain
[4] Hosp Univ HM Monteprincipe, Anaesthesiol Dept, Madrid, Spain
[5] Hosp Univ 12 Octubre, Electrophysiol Dept, Madrid, Spain
关键词
Conduction disturbances; TAVI; Edwards SAPIEN prosthesis; PERMANENT PACEMAKER; TRANSCATHETER; PREDICTORS; BLOCK; RISK; REPLACEMENT; MANAGEMENT;
D O I
10.1016/j.jelectrocard.2018.02.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The aim of this study is to describe electrocardiographic changes and conduction abnormalities in patients undergoing transcatheter aortic valve implantation (TAVI). Methods: 76 patients who underwent TAVI using Edwards Sapien 3 prosthesis were included, comparing electrocardiographic registries at admission, post-procedure and before discharge. Results: Patients after TAVI presented a longer PR interval, a wider QRS, and a longer corrected QT, with a left deviation of QRS axis and T waves: reversible changes that tended to correct in the following days after TAVI. Complete atrioventricular block incidence was 2.9%. New-onset left bundle branch block (LBBB) incidence was 39%, although solved in almost half of patients before discharge. Conclusions: TAVI was associated with different reversible electrocardiographic changes that suggest a transient impact on the conduction system. One of every five patients presented permanent LBBB after valve implant. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:416 / 421
页数:6
相关论文
共 24 条
[1]  
Bazett HC, 1920, HEART-J STUD CIRC, V7, P353
[2]   Impact of Permanent Pacemaker Implantation on Clinical Outcome Among Patients Undergoing Transcatheter Aortic Valve Implantation [J].
Buellesfeld, Lutz ;
Stortecky, Stefan ;
Heg, Dik ;
Hausen, Sven ;
Mueller, Ralf ;
Wenaweser, Peter ;
Pilgrim, Thomas ;
Gloekler, Steffen ;
Khattab, Ahmed A. ;
Huber, Christoph ;
Carrel, Thierry ;
Eberle, Balthasar ;
Meier, Bernhard ;
Boekstegers, Peter ;
Jueni, Peter ;
Gerckens, Ulrich ;
Grube, Eberhard ;
Windecker, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (06) :493-501
[3]  
Eksik A, 2013, J INVASIVE CARDIOL, V25, P305
[4]   Risk for Permanent Pacemaker After Transcatheter Aortic Valve Implantation: A Comprehensive Analysis of the Literature [J].
Erkapic, Damir ;
De Rosa, Salvatore ;
Kelava, Augustin ;
Lehmann, Ralf ;
Fichtlscherer, Stephan ;
Hohnloser, Stefan H. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (04) :391-397
[5]   Transfemoral Implantation of Edwards Sapien XT Aortic Valve Without Previous Valvuloplasty: Role of 2D/3D Transesophageal Echocardiography [J].
Garcia, Eulogio ;
Almeria, Carlos ;
Unzue, Leire ;
Jimenez-Quevedo, Pilar ;
Cuadrado, Ana ;
Macaya, Carlos .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (06) :868-876
[6]   Predictors and Course of High-Degree Atrioventricular Block After Transcatheter Aortic Valve Implantation Using the CoreValve Revalving system [J].
Guetta, Victor ;
Goldenberg, Gustavo ;
Segev, Amit ;
Dvir, Danny ;
Kornowski, Ran ;
Finckelstein, Arik ;
Hay, Ilan ;
Goldenberg, Ilan ;
Glikson, Michael .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 108 (11) :1600-1605
[7]  
Harold JG, 2014, J AM COLL CARDIOL, V63, pE57, DOI [10.1016/j.jacc.2014.02.537, 10.1016/j.jacc.2014.02.536, 10.1016/j.jtcvs.2014.05.014]
[8]   Predictors for Permanent Pacing After Transcatheter Aortic Valve Implantation [J].
Haworth, Peter ;
Behan, Miles ;
Khawaja, Muhammed ;
Hutchinson, Nevil ;
de Belder, Adam ;
Trivedi, Uday ;
Laborde, Jean Claude ;
Hildick-Smith, David .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (05) :751-756
[9]   Left Bundle-Branch Block Induced by Transcatheter Aortic Valve Implantation Increases Risk of Death [J].
Houthuizen, Patrick ;
Van Garsse, Leen A. F. M. ;
Poels, Thomas T. ;
de Jaegere, Peter ;
van der Boon, Robert M. A. ;
Swinkels, Ben M. ;
ten Berg, Jurrien M. ;
van der Kley, Frank ;
Schalij, Martin J. ;
Baan, Jan, Jr. ;
Cocchieri, Ricardo ;
Brueren, Guus R. G. ;
van Straten, Albert H. M. ;
den Heijer, Peter ;
Bentala, Mohamed ;
van Ommen, Vincent ;
Kluin, Jolanda ;
Stella, Pieter R. ;
Prins, Martin H. ;
Maessen, Jos G. ;
Prinzen, Frits W. .
CIRCULATION, 2012, 126 (06) :720-728
[10]   Conduction Abnormalities and Pacemaker Implantations After SAPIEN 3 Vs SAPIEN XT Prosthesis Aortic Valve Implantation [J].
Husser, Oliver ;
Kessler, Thorsten ;
Burgdorf, Christof ;
Templin, Christian ;
Pellegrini, Costanza ;
Schneider, Simon ;
Kasel, Albert Markus ;
Kastrati, Adnan ;
Schunkert, Heribert ;
Hengstenberg, Christian .
REVISTA ESPANOLA DE CARDIOLOGIA, 2016, 69 (02) :141-148