Automated segmentation of the left ventricle in cardiac MRI

被引:202
作者
Kaus, MR
von Berg, J
Weese, R
Niessen, W
Pekar, V
机构
[1] Philips Res Labs, Sector Tech Syst, D-22335 Hamburg, Germany
[2] Univ Utrecht, Ctr Med, Image Sci Inst, NL-3584 CX Utrecht, Netherlands
关键词
image post-processing; segmentation; deformable models; shape models; cardiac MRI;
D O I
10.1016/j.media.2004.06.015
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
We present a fully automated deformable model technique for myocardium segmentation in 3D MRI. Loss of signal due to blood flow, partial volume effects and significant variation of surface grey value appearance make this a difficult problem. We integrate various sources of prior knowledge learned from annotated image data into a deformable model. Inter-individual shape variation is represented by a statistical point distribution model, and the spatial relationship of the epi- and endocardium is modeled by adapting two coupled triangular surface meshes. To robustly accommodate variation of grey value appearance around the myocardiac surface, a prior parametric spatially varying feature model is established by classification of grey value surface profiles. Quantitative validation of 121 3D MRI datasets in end-diastolic (end-systolic) phase demonstrates accuracy and robustness, with 2.45 mm (2.84 mm) mean deviation from manual segmentation. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:245 / 254
页数:10
相关论文
共 21 条
[1]  
[Anonymous], LECT NOTES COMPUTER
[2]   COMBINING POINT DISTRIBUTION MODELS WITH SHAPE MODELS BASED ON FINITE-ELEMENT ANALYSIS [J].
COOTES, TF ;
TAYLOR, CJ .
IMAGE AND VISION COMPUTING, 1995, 13 (05) :403-409
[3]  
Duda R. O., 1973, PATTERN CLASSIFICATI
[4]  
Edwards G. J., 1998, LNCS, V2, P484, DOI [DOI 10.1109/34.927467, DOI 10.1007/BFB0054760]
[5]  
Fletcher PT, 2002, 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, P26, DOI 10.1109/ISBI.2002.1029184
[6]   Three-dimensional modeling for functional analysis of cardiac images: A review [J].
Frangi, AF ;
Niessen, WJ ;
Viergever, MA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (01) :2-25
[7]  
Gill P. E., 1981, PRACTICAL OPTIMIZATI
[8]  
Golub G. H., 1996, MATRIX COMPUTATIONS
[9]  
Jolly MP, 2001, EIGHTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOL I, PROCEEDINGS, P501, DOI 10.1109/ICCV.2001.937558
[10]   SNAKES - ACTIVE CONTOUR MODELS [J].
KASS, M ;
WITKIN, A ;
TERZOPOULOS, D .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1987, 1 (04) :321-331