A Critical Review of Microelectrode Arrays and Strategies for Improving Neural Interfaces

被引:86
作者
Ferguson, Morgan [1 ]
Sharma, Dhavan [1 ]
Ross, David [1 ]
Zhao, Feng [1 ]
机构
[1] Michigan Technol Univ, Dept Biomed Engn, 1400 Townsend Dr, Houghton, MI 49931 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
foreign body responses; microelectrode arrays; stiffness; surface modification; BLOOD-BRAIN-BARRIER; TISSUE-RESPONSE; MECHANICAL-PROPERTIES; NONNEURONAL CELLS; OXIDATIVE STRESS; MICROGLIA; ASTROCYTES; ELECTRODES; RECORDINGS; IMPLANTS;
D O I
10.1002/adhm.201900558
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Though neural interface systems (NISs) can provide a potential solution for mitigating the effects of limb loss and central nervous system damage, the microelectrode array (MEA) component of NISs remains a significant limiting factor to their widespread clinical applications. Several strategies can be applied to MEA designs to increase their biocompatibility. Herein, an overview of NISs and their applications is provided, along with a detailed discussion of strategies for alleviating the foreign body response (FBR) and abnormalities seen at the interface of MEAs and the brain tissue following MEA implantation. Various surface modifications, including natural/synthetic surface coatings, hydrogels, and topography alterations, have shown to be highly successful in improving neural cell adhesion, reducing gliosis, and increasing MEA longevity. Different MEA surface geometries, such as those seen in the Utah and Michigan arrays, can help alleviate the resultant FBR by reducing insertion damage, while providing new avenues for improving MEA recording performance and resolution. Increasing overall flexibility of MEAs as well as reducing their stiffness is also shown to reduce MEA induced micromotion along with FBR severity. By combining multiple different properties into a single MEA, the severity and duration of an FBR postimplantation can be reduced substantially.
引用
收藏
页数:16
相关论文
共 133 条
[1]  
Agorelius J, 2015, FRONT NEUROSCI-SWITZ, V9, DOI [10.3389/fnins.7015.00331, 10.3389/fnins.2015.00331]
[2]   NEUROSCIENCE Glia - more than just brain glue [J].
Allen, Nicola J. ;
Barres, Ben A. .
NATURE, 2009, 457 (7230) :675-677
[3]   Foreign body reaction to biomaterials [J].
Anderson, James M. ;
Rodriguez, Analiz ;
Chang, David T. .
SEMINARS IN IMMUNOLOGY, 2008, 20 (02) :86-100
[4]   Biological responses to materials [J].
Anderson, JM .
ANNUAL REVIEW OF MATERIALS RESEARCH, 2001, 31 :81-110
[5]   Equal Numbers of Neuronal and Nonneuronal Cells Make the Human Brain an Isometrically Scaled-Up Primate Brain [J].
Azevedo, Frederico A. C. ;
Carvalho, Ludmila R. B. ;
Grinberg, Lea T. ;
Farfel, Jose Marcelo ;
Ferretti, Renata E. L. ;
Leite, Renata E. P. ;
Jacob Filho, Wilson ;
Lent, Roberto ;
Herculano-Houzel, Suzana .
JOURNAL OF COMPARATIVE NEUROLOGY, 2009, 513 (05) :532-541
[6]  
Babcock AA, 2003, J NEUROSCI, V23, P7922
[7]   Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates [J].
Barrese, James C. ;
Rao, Naveen ;
Paroo, Kaivon ;
Triebwasser, Corey ;
Vargas-Irwin, Carlos ;
Franquemont, Lachlan ;
Donoghue, John P. .
JOURNAL OF NEURAL ENGINEERING, 2013, 10 (06)
[8]   Biology of oligodendrocyte and myelin in the mammalian central nervous system [J].
Baumann, N ;
Pham-Dinh, D .
PHYSIOLOGICAL REVIEWS, 2001, 81 (02) :871-927
[9]   Neuroinflammation, oxidative stress, and blood-brain barrier (BBB) disruption in acute Utah electrode array implants and the effect of deferoxamine as an iron chelator on acute foreign body response [J].
Bennett, Cassie ;
Mohammed, Farrah ;
Alvarez-Ciara, Anabel ;
Nguyen, Michelle A. ;
Dietrich, W. Dalton ;
Rajguru, Suhrud M. ;
Streit, Wolfgang J. ;
Prasad, Abhishek .
BIOMATERIALS, 2019, 188 :144-159
[10]   Blood brain barrier (BBB)-disruption in intracortical silicon microelectrode implants [J].
Bennett, Cassie ;
Samikkannu, Malaroviyam ;
Mohammed, Farrah ;
Dietrich, W. Dalton ;
Rajguru, Suhrud M. ;
Prasad, Abhishek .
BIOMATERIALS, 2018, 164 :1-10